GB/T 11297.1-2017 in English
VALIDTest method for wavefront distortion of laser rods
- Issued on:2017-05-31
- Implemented on:2017-12-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$136.00
《GB/T 11297.1-2017激光棒波前畸变的测量方法》由339-1(工业和信息化部(电子))归口,主管部门为工业和信息化部(电子)。
Introduction
1. Background of standard formulation and analysis of technological evolution
GB/T 11297.1-2017 "Measurement method of wavefront distortion of laser rods" is an important standard for the laser field, replacing the old version GB/T 11297.1-2002. The new standard has made important revisions in terms of test conditions, requirements for laser rods to be tested, and test equipment.
2. Comparative analysis of standard frameworks
| Standard version | Test conditions | Requirements for tested laser rods | New content |
|---|---|---|---|
| GB/T 11297.1—2002 | - Temperature: $25^\circ\mathrm{C}\pm2^\circ\mathrm{C}$ - Relative humidity: ≤80% | - Parallelism better than $50''$ - No specific end face pitting and scratch restrictions | No measurement precision requirements |
| GB/T 11297.1—2017 | - Temperature: $22^\circ\mathrm{C}\pm5^\circ\mathrm{C}$ - Relative humidity: ≤85% | - Parallelism better than or equal to $30''$ - End surface pitting diameter φ0.004mm~φ0.1mm, number less than $0.8D_\mathrm{0}$ | Increase measurement precision requirements (≤10%) |
3. Interpretation of standard technical specifications
3.1 Test conditions and environmental control
Test temperature: $22^\circ\mathrm{C}\pm5^\circ\mathrm{C}$, to ensure that the thermal expansion coefficient of the laser rod material has an acceptable range on the wavefront distortion.
Relative humidity: ≤85%, to prevent moisture in the air from affecting the test accuracy.
3.2 Requirements for the laser rod to be tested
- End face parallelism: better than or equal to $30''$, to ensure the accuracy of wavefront distortion measurement;
- End face perpendicularity to the rod axis: better than or equal to $5^\prime$, to reduce the influence of optical path deviation;
- End face cleanliness: no obvious dust and stains, to avoid optical interference.
4. Implementation Suggestions
Test equipment selection:It is recommended to use a digital wavefront interferometer with a resolution of 128×128 pixels or above to ensure that the measurement accuracy requirements are met.
Environmental control:The test should be carried out in a constant temperature and humidity environment. It is recommended to use professional equipment to maintain stable laboratory conditions.
Data processing:According to equations (1) and (2), the test wavelength is converted to the working wavelength of the laser rod to ensure the accuracy of the measurement results.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 5593-2015 in English
Structure ceramic materials used in electronic component and device
2015-05-15 -

GB/T 16304-2008 in English
Test methods of the properties for piezoelectric ceramics - Test for relation between electric field and strain
2008-08-04 -

GB 2413-1981 in English
Piezoelectric ceramic materials - Measuring methods for determination of volume density
1980-12-31 -

GB/T 25494-2010 in English
Test methods for composition analysis of getters
2010-12-01 -

GB/T 14015-1992 in English
on sapphire epitaxial wafers
1992-01-02 -

GB/T 9394-1998 in English
Potassium silicate solution for use in electronic industry
1998-06-17 -

GB/T 36952-2018 in English
Test method for surface scratch resistance of flat panel display(FPD)polarizing film
2018-12-28 -

GB/T 11446.1-2013 in English
Electronic Grade Water
2013-12-31 -

GB/T 2414.1-1998 in English
Test methods for the properties of piezoelectric ceramics Radial extension vibration mode for disk
1998-11-10 -

GB/T 13842-2017 in English
Neodymium-doped Yttrium Aluminum Garnet laser rods
2017-05-31