GB/T 11969-2020 in English
VALIDTest methods of autoclaved aerated concrete
- Issued on:2020-09-29
- Implemented on:2021-08-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$243.00
《GB/T 11969-2020蒸压加气混凝土性能试验方法》由TC197(全国水泥制品标准化技术委员会)归口,主管部门为中国建筑材料联合会。
Introduction
Standard Revision and Technological Evolution
| Technical Parameters | 2008 Edition | 2020 Edition | Main Changes |
|---|---|---|---|
| Measuring Instruments | General Requirements | Specified in Chapters | Separate provisions in Chapters 3.1/4.1 |
| Moisture Content Calculation | Mass Moisture Content | Added Volume Moisture Content | Formula (3) and Clause 3.5.3 |
| Antifreeze test | -15℃freeze for 4h | -15℃freeze for 8h | 6.3.5 Cycle period extension |
Analysis of core test methods
1. Dry density and water absorption test
Key equipment: Electric blast drying oven (200℃), Constant temperature water bath (20±2℃). Specimen preparation requirements:
- 2 groups of 100mm cubic specimens
- Sampling along the gas emission direction from top to bottom
- Dimension deviation ≤±1mm
Application case:
When an AAC board factory used a digital caliper (0.1mm accuracy) for measurement, it was found that the verticality of the specimen exceeded the standard, resulting in a dry density deviation of 5%. After adjusting the fixture, the data returned to the normal range.
2. Mechanical properties test
| Test type | Specimen size | Loading rate | Key equipment |
|---|---|---|---|
| Compressive strength | 100×100×100mm | 2.0±0.5kN/s | Material testing machine |
| Flexural strength | 100×100×400mm | 0.20±0.05kN/s | Arc roller device |
Note: The moisture content needs to be controlled within the range of 10±2% (Clause 4.2.7)
Suggestions for the implementation of the standard
- The laboratory should establish the temperature and humidity calibration records of the drying shrinkage test chamber (Clause 5.1.4)
- It is recommended to use an automatic control box for carbonization test, and the manual device needs to detect the CO2 concentration daily (Clause 7.3.2)
- The antifreeze specimen needs to be immersed in water in steps during the pre-wetting stage (Clause 6.3.2)
Technical difficulties:
In the elastic modulus test, a testing agency found that the difference between δ4 and δ5 exceeded 0.003mm. After improving the specimen centering device, it met the requirements (Clause 4.3.5.j)

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB 25779-2010 in English
Loadbearing concrete perforated bricks
2010-12-23 -

GB/T 19685-2017 in English
Prestressed concrete cylinder pipe
2017-03-09 -

GB/T 9694-2014 in English
Circular concrete pole
2014-12-05 -

GB/T 7897-2008 in English
Test methods of mechanical properties of mortar for ferrocement
2008-07-30 -

GB/T 33544-2017 in English
Glass fiber and magnesium cement board
2017-03-09 -

GB/T 15345-2017 in English
Test methods of concrete pipes for water transmisson
2017-05-31 -

GB/T 11836-2023 in English
Concrete and reinforced concrete sewer pipes
2023-03-17 -

GB 28635-2012 in English
Precast concrete paving units
2012-07-31 -

GB 4623-2014 in English
Circular concrete pole
2014-12-05 -

GB/T 3691-2008 in English
Mechanical properties testing method of steel wool cement tile
2008-07-30