GB/T 20833.4-2021 in English
VALIDRotating electrical machines—The winding insulation—Part 4: Measurement of insulation resistance and polarization index
- Issued on:2021-03-09
- Implemented on:2021-10-01
- File Format:PDF
- Delivery:Via email within 5 business days
$534.00
《GB/T 20833.4-2021旋转电机 绕组绝缘 第4部分:绝缘电阻和极化指数测量》由TC26(全国旋转电机标准化技术委员会)归口,主管部门为中国电器工业协会。
Introduction
Analysis of the core content of the standard
This standard is equivalent to IEC 60034-27-4:2018, which specifies the test method and evaluation criteria for the insulation resistance and polarization index of stator and rotor windings of rotating electrical machines of 750W and above. It is applicable to the insulation status assessment of AC/DC motors and provides a standardized basis for manufacturing inspection, maintenance and overhaul.
Comparison of key technical indicators
| Insulation type | Minimum insulation resistance (40℃) | Minimum polarization index | Temperature correction parameter X(K) |
|---|---|---|---|
| Shellac/asphalt-based high-voltage insulation | 100 MΩ | 1.5 | 10 |
| Synthetic resin-based high-voltage insulation | (rated voltage kV+1)×1 MΩ | 2.0 | 17 |
| Low voltage random-wound/formed winding | 5 MΩ | Not applicable | No correction required |
Test principles and influencing factors
Insulation resistance measurement is based on DC megger or indirect voltage-current method. The equivalent circuit contains four current components:
- Capacitance current IC: Transient current that decays in milliseconds
- Polarization current IP: Absorption current that decays in minutes
- Conductance current IG: Reflects the conductive properties of the insulation body
- Surface leakage current IL: Significantly affected by humidity/pollution
Temperature correction formula: Ric = RiT × 0.5(40-T)/X, where X value needs to be determined through experiments (see Appendix D)
Implementation suggestions and case analysis
Typical problem handling solutions
- Low insulation resistance: Check the surface contamination of the winding, clean it with anhydrous ethanol and then retest
- Abnormal polarization index: PI<1.5 may indicate that the insulation is damp and needs to be dried with hot air at 80℃ for 72 hours
- Impact of end anti-corona layer: Continuous anti-corona layer design may result in PI≈1, which needs to be judged in combination with historical data
Essential elements of test report
Should include ambient temperature and humidity, class=instrument>Test instrument model, connection method, corrected Ri1/Ri10 value, and a list of auxiliary equipment connected to the equipment under test.
Standard Evolution and Technological Innovation
Main changes of this standard compared with the 2008 version:
- Added temperature correction exemption clause for synthetic resin insulation (when Ri1>5000MΩ)
- Specified special test conditions for water-cooled windings
- Supplemented theoretical description of end anti-corona layer current (Appendix C)
Future technical development directions include online polarization index monitoring, AI-based insulation aging prediction, etc.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 17948.4-2024 in English
Rotating electrical machines—Functional evaluation of insulation systems (Type II)—Procedures for form-wound windings—Electrical endurance qualification
2024-08-23 -

GB/T 997-2022 in English
Classification of types of construction,mounting arrangements and terminal box position (IM Code) for rotating electrical machines
2022-10-12 -

GB/T 20833.3-2018 in English
Rotating electrical machines—Stator winding insulation of rotating electrical machines—Part 3:Dielectric dissipation factor measurement
2018-07-13 -

GB/T 4772.2-1999 in English
Dimensions and output series for rotating electrical machines - Part 2: Frame numbers 355 to 1000 and flange numbers 1180 to 2360
1999-02-02 -

GB/Z 113.34-2025 in English
Rotating electrical machines—Part 34:AC adjustable speed rolling mill motors
2025-12-03 -

GB/T 10068-2020 in English
Mechanical vibration of certain machines with shaft heights 56 mm and higher—Measurement, evaluation and limits of vibration severity
2020-03-31 -

GB/T 22714-2008 in English
Test specifications of interturn insulation of form-wound winding for AC low-voltage electrical machines
2008-12-30 -

GB/T 12351-2008 in English
Environmental technical requirements of rotating electric machines for tropical use
2008-06-13 -

GB/T 13958-2022 in English
Test methods for small power permanent magnet synchronous motors
2022-12-30 -

GB/T 17948.1-2018 in English
Rotating electrical machines—Functional evaluation of insulation systems—Test procedures for wire-wound windings—Thermal evaluation and classification