《GB/T 22714-2008交流低压电机成型绕组匝间绝缘试验规范》由TC26(全国旋转电机标准化技术委员会)归口,主管部门为中国电器工业协会。
本标准为首次发布。本标准规定了交流电机成型绕组匝间绝缘试验方法、试验参数和试验限值。
本标准适用于额定电压为1140V 及以下的中小型交流电机成型绕组匝间绝缘检测。
1 Scope
This standard specifies the test methods, test parameters and test limits of interturn insulation of form-wound winding for AC electrical machines.
This standard is applicable to the inspection of interturn insulation of form-wound winding for small and medium AC electrical machine with rated voltage of 1140V or below.
2 Normative References
The following normative documents contain provisions which, through reference in this text, constitute provisions of this standard. For dated references, subsequent amendments (excluding corrections), or revisions, of any of these publications do not apply to this standard. However, parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document referred to applies.
GB 755-2008 Rotating Electrical Machines - Rating and Performance (IEC 60034-1: 2004, IDT)
GB/T 8170-2008 Rules of Rounding off for Numerical Values & Expression and Judgement of Limiting Values
JB/T 9615.1-2000 Test Methods of the Interturn Insulation on Random Wound Winding for Ac Low-voltage Machines
JB/T 9615.2-2000 Test Limits of the Interturn Insulation on Random Wound Winding for Ac Low-voltage Machines
JB/T 10098-2000 Impulse Voltage Withstand Levels of Rotating A.C. Machines With Form-wound Stator Coils
3 Terms and Definitions
For the purposes of this standard, the following terms and definitions apply.
3.1
comparison method of impulse waveforms
one test method of interturn insulation of electrical machine winding (or coil) with impulse voltage
Principle: directly apply the impulse voltage wave with specified peak and wave front time on a tested piece and reference winding (or coil) with same design alternately (or simultaneously), and then detect whether the interturn insulation of electrical machine winding (or coil) is in good condition by their damped oscillating waveform difference caused by impulse voltage
Foreword I
1 Scope
2 Normative References
3 Terms and Definitions
4 Test Principle
5 Test Instruments and Requirements
6 Test Methods
7 Waveform in Test and Its Display
8 Selection Principle of Test Methods
9 Test Judgment
10 Test and Comparison Parameters
11 Test Limit
12 Repeated Tests and Test Procedures

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 17948.4-2024 in English
Rotating electrical machines—Functional evaluation of insulation systems (Type II)—Procedures for form-wound windings—Electrical endurance qualification
2024-08-23 -

GB/T 4772.2-1999 in English
Dimensions and output series for rotating electrical machines - Part 2: Frame numbers 355 to 1000 and flange numbers 1180 to 2360
1999-02-02 -

GB/Z 113.34-2025 in English
Rotating electrical machines—Part 34:AC adjustable speed rolling mill motors
2025-12-03 -

GB/T 7060-2019 in English
General specifications for rotary electrical machines in ships
2019-05-10 -

GB/T 997-2022 in English
Classification of types of construction,mounting arrangements and terminal box position (IM Code) for rotating electrical machines
2022-10-12 -

GB/T 10068-2020 in English
Mechanical vibration of certain machines with shaft heights 56 mm and higher—Measurement, evaluation and limits of vibration severity
2020-03-31 -

GB/T 13958-2022 in English
Test methods for small power permanent magnet synchronous motors
2022-12-30 -

GB/T 20833.3-2018 in English
Rotating electrical machines—Stator winding insulation of rotating electrical machines—Part 3:Dielectric dissipation factor measurement
2018-07-13