GB/T 21188-2007 in English
VALIDMeasurement of gas flow by means of critical flow Venturi nozzles
- Issued on:2007-11-14
- Implemented on:2008-05-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$553.00
《GB/T 21188-2007用临界流文丘里喷嘴测量气体流量》由TC124(全国工业过程测量控制和自动化标准化技术委员会)归口,TC124SC1(全国工业过程测量控制和自动化标准化技术委员会温度、流量、机械量、物位、显示仪表、执行器和结构装置分会)执行,主管部门为中国机械工业联合会。
本标准规定了测量气体质量流量的临界流文丘里喷嘴的几何尺寸和使用方法。
Scope
This standard specifies the geometric dimensions and usage method (installation and working conditions in the system) of the critical flow venturi nozzle (CFVN) for measuring gas mass flow rate, and gives the data required for calculating the flow rate and its uncertainty. It is suitable for Venturi nozzles where the gas flow is accelerated to a critical velocity (equal to the local speed of sound) at the throat, and there is only a steady flow of single-phase gas at the throat. At the critical velocity, the gas mass flow rate through the Venturi nozzle is the maximum flow rate possible under practical upstream conditions. Critical flow Venturi nozzles should only be used within the specified limits for the nozzle throat to inlet diameter ratio and throat Reynolds number. The critical flow Venturi nozzles involved in this standard have done a large number of direct calibration tests, which can ensure that the given critical flow Venturi nozzle discharge coefficient is within a predictable uncertainty limit. The data given in this standard are suitable. In the following cases: the upstream pipeline of the critical flow Venturi nozzle is a circular cross-section pipeline; or the upstream of the critical flow Venturi nozzle, or the upstream of a set of critical flow Venturi nozzles installed in groups can be regarded as a large space. This group configuration provides the possibility to install critical flow venturi nozzles in parallel, so that a larger flow rate can be obtained. For high accuracy measurement, this standard discusses the precise machining of critical flow venturi nozzles for low Reynolds numbers.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 2624.6-2024 in English
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full—Part 6: Wedge devices
2024-09-29 -

GB/T 25918-2010 in English
Portable calibration instrument for water meters
2011-01-14 -

GB/T 31130-2014 in English
Coriolis mass flow meter
2014-09-03 -

GB/T 29815-2013 in English
The electromagnetic flowmeter based on HART protocol general technical specification
2013-11-12 -

GB/T 20727-2006 in English
Measurement of fluid flow in closed conduits - Thermal mass flowmeters
2006-12-31 -

GB/T 9248-2008 in English
Methods of evaluating the performance of flowmeters for incompressible fluids
2008-07-28 -

GB/T 18659-2023 in English
Measurement of fluid flow in closed conduits—Guidance for the use of electromagnetic flowmeters
2023-08-06