Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
single-speed three-phase cage induction motors single-speed three-phase cage induction motors scopethis standard starting performance dual-voltage motors current values nickel alloy welding wires diarrheal shellfish toxin programmable electrical medical systems
GB/T 21210-2016 in English

GB/T 21210-2016 in English

VALID

Starting performance of single-speed three-phase cage induction motors

  • Issued on:2016-08-29
  • Implemented on:2017-03-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $190.00
$185.00
Standard No: GB/T 21210-2016
Document status: VALID
Superseded by: GB/T 21210-2026 Starting performance of single-speed three-phase cage induction motors
Superseded on: 2027-02-01
Title in English: Starting performance of single-speed three-phase cage induction motors
Title in Chinese: 单速三相笼型感应电动机起动性能
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2016-08-29
Implemented on: 2017-03-01
Superseding: GB/T 21210-2007 Starting performance of single-speed three-phase cage induction motors
ICS Classification: 29.160.01-Rotating machinery in general
Chinese Classification: K20-Electric rotating machinery in general
Professional Classification: GB-National Standard
Related Keywords: single-speed three-phase cage induction motors
single-speed three-phase cage induction motors scopethis standard
starting performance
dual-voltage motors
current values
Related Topics: Three-phase inductance iec standard
electrokinetic
Fluid Response
Type tee performance
cage machine
mobile phase organic phase ph
Single phase motor 370
Small single chain medicine machine
GBT21210
GB/T 21210-2007
GB/T 21210-2016
electric motor
Telephone switchboard performance related
Braking method of three-phase AC motor
gb/t 21210
gbt 21210 2016
gbt21210

《GB/T 21210-2016单速三相笼型感应电动机起动性能》由TC26(全国旋转电机标准化技术委员会)归口,主管部门为中国电器工业协会。


Scope

This standard specifies 8 design parameters for the starting performance of 50Hz or 60Hz single-speed three-phase cage induction motors. The motor shall comply with the IEC60034 1 standard, and ●rated voltage shall not exceed 1000V; ●●● direct start or star-delta start; based on S1 working system; may have any kind of protection level and explosion-proof level. This standard also applies to dual-voltage motors with the same degree of magnetic saturation at both voltages. The torque values, apparent power values and current values given in this standard are limit values (minimum or maximum values, without tolerance). Note 1: This standard does not require each manufacturer to produce motors with all these 8 designs, and any design selected according to this standard will be negotiated between the manufacturer and the user. Note 2: Motors for special purposes may not follow the above 8 design requirements. Note 3: It should be noted that the values given by the manufacturer on the sample may include tolerances, and the tolerances shall comply with the provisions of the IEC60034-1 standard. Note 4: The locked rotor apparent power listed in the attached table corresponds to the symmetrical steady state current rms when the rotor is locked. When the motor is connected to the current, there will be an asymmetrical instantaneous peak current of 0.5 cycles, which is 1.8 to 2.8 times of the steady state value. The peak value and decay time of this current are a function of the motor design and closing phase angle.

Sample only — not a preview of GB/T 21210-2016
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend

  • GB/T 17948.4-2024 in English

    GB/T 17948.4-2024 in English

    Rotating electrical machines—Functional evaluation of insulation systems (Type II)—Procedures for form-wound windings—Electrical endurance qualification

    2024-08-23
  • GB/T 1971-2021 in English

    GB/T 1971-2021 in English

    Rotating electrical machines—Terminal markings and direction of rotation

    2021-10-11
  • GB/T 17948.1-2018 in English

    GB/T 17948.1-2018 in English

    Rotating electrical machines—Functional evaluation of insulation systems—Test procedures for wire-wound windings—Thermal evaluation and classification

    2018-07-13
  • GB/T 10068-2020 in English

    GB/T 10068-2020 in English

    Mechanical vibration of certain machines with shaft heights 56 mm and higher—Measurement, evaluation and limits of vibration severity

    2020-03-31
  • GB/T 7060-2019 in English

    GB/T 7060-2019 in English

    General specifications for rotary electrical machines in ships

    2019-05-10
  • GB/T 22714-2008 in English

    GB/T 22714-2008 in English

    Test specifications of interturn insulation of form-wound winding for AC low-voltage electrical machines

    2008-12-30
  • GB/T 4772.1-2025 in English

    GB/T 4772.1-2025 in English

    Dimensions and output series for rotating electrical machines—Part 1: Frame numbers 56 to 400 and flange numbers 55 to 1080

    2025-08-01
  • GB/T 29326-2023 in English

    GB/T 29326-2023 in English

    Selection of energy-efficient motors including variable speed applications—Application guidelines

    2023-12-28
  • GB/T 4772.2-1999 in English

    GB/T 4772.2-1999 in English

    Dimensions and output series for rotating electrical machines - Part 2: Frame numbers 355 to 1000 and flange numbers 1180 to 2360

    1999-02-02
  • GB/T 13958-2022 in English

    GB/T 13958-2022 in English

    Test methods for small power permanent magnet synchronous motors

    2022-12-30