Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
core test items test type frequency band range test level judgment criteria housing port immunity walks immunity introduction analysis 0.15-80mhz ±2kv/5khz judgment criteria a/b/c key points judgment criteria diec61000-6-2 ac power port electromagnetic compatibility universal design principles phosphorus compounds pump components
GB/T 24808-2022 in English

GB/T 24808-2022 in English

VALID

Electromagnetic compatibility for lifts, escalators and moving walks—Immunity

  • Issued on:2022-03-09
  • Implemented on:2022-10-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $280.00
$272.00
Standard No: GB/T 24808-2022
Document status: VALID
Title in English: Electromagnetic compatibility for lifts, escalators and moving walks—Immunity
Title in Chinese: 电梯、自动扶梯和自动人行道的电磁兼容 抗扰度
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2022-03-09
Implemented on: 2022-10-01
Superseding: GB/T 24808-2009 Electromagnetic compatibility—Product family standard for lifts,escalators and moving walks—Immunity
ICS Classification: 91.140.90-Lifts. Escalators
Chinese Classification: Q78-Elevator
Professional Classification: GB-National Standard
Related Keywords: core test items test type frequency band range test level judgment criteria housing port immunity
walks immunity introduction analysis
0.15-80mhz ±2kv/5khz judgment criteria a/b/c key points
judgment criteria diec61000-6-2 ac power port
electromagnetic compatibility
Related Topics: Electromagnetic Compatibility
Electromagnetic Immunity
Immunity Standard
Immunity
Magnetic foreign body self
gradient
escalator
Automatic Gradient
"Operation Service Specifications for Elevators, Escalators and Moving Walks"
Gradient Gradient Box
Shibei pedestrian elevator
and the gradient of
Gradient Gradient
Gradient Gradient Peak
Gradient
gradient peak gradient
Capacitor self-discharge
automatic parallel channel
Capacitance + self-discharge
Gradient + Gradient
underwater voltage gradient
automatic sem
electromagnetic disturbance
Magnetic gradiometer
Capacitor automatic discharge
automatic disease resistance
voltage gradient
Automatic constant volume
surface potential gradient
Escalators and moving walks
moving walk
GBT24808
GB/T 24808-2009
GBT 24808-2022
Elevator GB
escalator latest
Elevator, escalator and moving walkway decoration technology
gb/t24808-2022
gbt24808
gb/t24808
British Standard for Escalators
gb/t 24808-2022
gb/t 24808
gbt24808-2022

《GB/T 24808-2022电梯、自动扶梯和自动人行道的电磁兼容 抗扰度》由TC196(全国电梯标准化技术委员会)归口,主管部门为国家标准化管理委员会。


Introduction

Analysis of key technical points of the standard

Comparison table of core test items
Test type Frequency band range Test level Judgment criteria
Housing port immunity 0.8-18GHz 3V/m→10V/m Judgment criteria D
IEC61000-6-2
AC power port 0.15-80MHz ±2kV/5kHz Judgment criteria A/B/C

Key points of technological evolution

Major improvements of the 2022 version include:

  • Added protection requirements for dedicated communication frequency bands: added base station scenario tests at 890MHz-7GHz
  • Strict enclosure port standards: the field stress in the adjacent area is increased to 27V/m (hazardous location frequency band)
  • Clear safety circuit testing: maximum current limit when using integrated test bench

Implementation recommendations section

Pay special attention during practice:

  1. It is recommended to adopt a layered shielding design: the outer layer of the control cabinet/cable shielding needs to reach 65dB attenuation
  2. Purchase certified equipment cables: meet the AN30 locomotive cable interface requirements of the ISO7637 standard
  3. System debugging priority: perform routine EMC tests first, then verify safety circuit criterion D

Sample only — not a preview of GB/T 24808-2022
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend