GB/T 28599-2020 in English
VALIDDetermination of phthalate esters in cosmetics
- Issued on:2020-09-29
- Implemented on:2021-01-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$243.00
《GB/T 28599-2020化妆品中邻苯二甲酸酯类物质的测定》由TC374(全国质量监管重点产品检验方法标准化技术委员会)归口,主管部门为国家标准化管理委员会。
Introduction
Core changes in the standard update
| Revision dimensions | 2012 version | 2020 version |
|---|---|---|
| Number of test substances | 18-22 | Unified to 24 |
| Scope of matrix application | HPLC method is applicable to nail polish | HPLC method excludes nail polish |
| Limit of detection (LOD) | Large differences between methods | GC/MS method is unified to 1.0mg/kg |
Comparison of technical methods
Method 1: GC/MS (arbitration method)
Innovation: Silica/PSA solid phase extraction column is used for purification, and SIM mode scanning uses the quantitative ion abundance ratio as the qualitative basis
Gas chromatography-mass spectrometryParameters:
- Chromatographic column: 5% phenyl-methylpolysiloxane capillary column
- Temperature program: 60℃(1min)→220℃(4min)→290℃(5min)
- Characteristic ions: DMP(163), DEHP(149), etc.
Method 2: HPLC
Optimization: Added gradient elution program (methanol/acetonitrile-water system), DAD detector 240nm wavelength analysis
High performance liquid chromatography Key conditions:
- Chromatographic column: XDB C8 (250mm×4.6mm,5μm)
- Flow rate: 1.0mL/min
- Column temperature: 40℃
Third method: GC
Application scenario: Routine analysis of FID detector, attention should be paid to the interference of nail polish matrix
Difference in heating program:
- 220℃ for 4.5min (0.5min longer than GC/MS)
- Final heating rate 15℃/min (20℃/min for GC/MS)
Suggestions for the implementation of the standard
Main points for matrix pretreatment
- Aqueous agents: Direct extraction with n-hexane to avoid contamination of plastic containers
- Cream: Methanol ultrasonication requires sodium chloride demulsification
- Solid: Sea sand is recommended for auxiliary grinding of lipstick samples
Quality control requirements
- Blank tests must be conducted simultaneously
- Relative deviation of parallel samples ≤15%
- Positive results must be repeated by GC/MS
Technology evolution analysis
The revision of this standard reflects three major trends: ①Detection sensitivity improved (GC/MS quantitative limit reduced from 5.0mg/kg to 2.5mg/kg); ② The universality of the method was enhanced (full coverage of 24 substances); ③ Green detection concept (reducing the amount of organic solvents, solid phase extraction instead of liquid-liquid extraction).

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 26513-2023 in English
Lip moisturizer(gel,cream)
2023-03-17 -

GB/T 44428-2024 in English
Determination of cannabidiol and tetrahydrocannabinol in cosmetics—Liquid chromatography tandem mass spectrometry
2024-08-23 -

GB/T 13531.1-2008 in English
General methods on determination of cosmetics—Determination of pH
2008-12-28 -

GB/T 22728-2008 in English
Determination of butylated hydroxyanisole (BHA) and butylated hydroxytoluene (BHT) in cosmetics—High performance liquid chromatography
2008-12-31 -

GB/T 29680-2026 in English
Facial washing milk(cream,liquid,mousse,gel,powder)
2026-02-27 -

GB/T 29990-2013 in English
Skin care oil
2013-11-27 -

GB/T 36923-2018 in English
Identification of pearl powder—X-ray diffraction analysis
2018-12-28