Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
safety requirements standard safety dimensionnfl1 equipmentfl2 technical requirements refrigeration system safety liquid level protection flash point control-≤ semi-trailer swap operation terminal requirements rear projection displays scopethis specification pollution-free food shiitake mushrooms scopethis standard
GB/T 32710.3-2016 in English

GB/T 32710.3-2016 in English

VALID

Safety requirements for environmental testing and conditioning equipment-Part 3:Refrigerated baths

  • Issued on:2016-06-14
  • Implemented on:2017-01-01
  • File Format:PDF
  • Delivery:Via email within 5 business days
Price(USD): $580.00
$563.00
Standard No: GB/T 32710.3-2016
Document status: VALID
Title in English: Safety requirements for environmental testing and conditioning equipment-Part 3:Refrigerated baths
Title in Chinese: 环境试验仪器及设备安全规范 第3部分:低温恒温槽
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 5 business days
Issued on: 2016-06-14
Implemented on: 2017-01-01
ICS Classification: 19.040-Environmental testing
Chinese Classification: N61-Basic laboratory equipment
Professional Classification: GB-National Standard
Related Keywords: safety requirements
standard safety dimensionnfl1 equipmentfl2
technical requirements
refrigeration system safety
liquid level protection flash point control-≤
Related Topics: Experimental cryometer
Environmental equipment
Test thermostat
Constant temperature test equipment
Automatic constant temperature concentrator
Low temperature test environment
Instrument constant temperature
Small constant temperature equipment
Thermostat
Yiheng Instrument
Thermostat
Thermostat
Low temperature ashing instrument
Constant temperature instrument
Special constant temperature equipment
Instrument thermostat
Hengyi Instrument
thermostat medical
Constant temperature instrument
Constant temperature water tank instrument
Temperature controller equipment
Constant temperature equipment
Low temperature constant temperature equipment
Constant temperature and low temperature equipment
Constant temperature and low temperature equipment
Laboratory constant temperature bath
Thermostat instrument
Low temperature constant temperature equipment
Low temperature ashing instrument
Low temperature environment box
Low temperature environment box
Low temperature constant temperature test
Safety requirements for environmental test instruments and equipment
Environmental test instruments and equipment safety
Cryogenic Instruments
Instrumentation and test equipment
Low temperature test equipment
Environmental equipment
Thermostat instrument
Environmental equipment
liquid thermostat
Test instruments and equipment
Instruments and Test Equipment
Test equipment and instruments
Instrument constant temperature bath
Constant temperature test equipment
Instrument thermostat
Cryogenic experiment sheet
Thermostatic Bath Instruments
Hengyi Instrument
Test and Instrument
Environmental test equipment
Heng Qi Instrument
Wen+
Constant temperature 20 degrees instrument
GB/T 32710.3
GB/T 32710.3-2016
Liquid nitrogen cryostat
Optical cryostat janis
Guangzhou Low Temperature Environment Reliability Test
Environmental protection equipment

《GB/T 32710.3-2016环境试验仪器及设备安全规范 第3部分:低温恒温槽》由TC526(全国实验室仪器及设备标准化技术委员会)归口,主管部门为中国机械工业联合会。


Introduction

Analysis of the core content of the standard

Safety dimensionNFL1 equipmentFL2 equipmentFL3 equipment
Liquid heat transfer mediumNon-flammable liquid onlyFlammable liquidFlammable liquid
Over-temperature protectionFixed temperature limiting deviceAdjustable temperature limiting deviceAdjustable temperature limiting + liquid level protection
Flash point control-≤(t-25)℃≤flash point temperature

Key technical requirements

1. Refrigeration system safety: The high-pressure side of the compressor must withstand 3 times the maximum working pressure (motor-compressor winding temperature ≤140℃), and special protection is required when the flammable refrigerant filling volume exceeds 150g.

2. Electrical protection: The exposed heating element must meet the IPx7 waterproof level, and 30mA residual current protection must be configured when the contact current exceeds 3.5mA.


3. Mechanical hazard protection: The stirring device should be equipped with an independent power cut-off interlock, and the pulley equipment must be equipped with a locking device (horizontal adjustment accuracy ±2.5mm).

Implementation suggestions

Selection basis: Select the equipment category according to the flash point of the medium. FL3 category requires a ventilation system

Maintenance points: Check the effectiveness of the pressure limiting device every month. The refrigerant charging error should be <±5%

Emergency treatment: When flammable liquid leaks, the power supply should be cut off immediately and special adsorption materials should be used for treatment

Sample only — not a preview of GB/T 32710.3-2016