Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
positive displacement refrigerant compressors single-stage positive displacement refrigerant compressors positive displacement refrigerant compressors introduction gb/t flow test method test method low-frequency communication office cables chitinase activity x-ray fluorescence spectrum
GB/T 34619-2017 in English

GB/T 34619-2017 in English

VALID

Test method for volumetric flow of positive displacement refrigerant compressors

  • Issued on:2017-09-29
  • Implemented on:2018-04-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $220.00
$214.00
Standard No: GB/T 34619-2017
Document status: VALID
Title in English: Test method for volumetric flow of positive displacement refrigerant compressors
Title in Chinese: 容积式制冷剂压缩机容积流量试验方法
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2017-09-29
Implemented on: 2018-04-01
ICS Classification: 27.200-Refrigerating technology
Professional Classification: GB-National Standard
Related Keywords: positive displacement refrigerant compressors
single-stage positive displacement refrigerant compressors
positive displacement refrigerant compressors introduction gb/t
flow test method
test method
Related Topics: Refrigerant Standard
Refrigerant Standard
volume of reagent
total integral dose
volume
Positive displacement compressor installation
volume method cassette
flow peak area
volume sample cell
Flow Method Validation
capacity mode
Classification of volumetric compressors
Flow Method Validation
Pseudocapacitive method
pi streaming method
Cassette volume method
Volumetric microphone mixer
Flow method validation
volume flow
operating volume
Flow Cytometry Reagents
compressor refrigerator
Mechanism content
American Compression Tester
flow sample volume
volume reagent
volume shrinkage
GBT34619
GB/T 34619-2017
Measuring accretion flow
Refrigerant compatibility testing
Flow cytometry reagent detection method
Positive displacement refrigeration compressors and compressor units
Test cylinder volume calibration method
Refrigerant compatibility testing
How to control flow of filling machine
Positive displacement compressor volumetric flow acceptance
current volume test
Container volume test
Flow cytometry preparation method
Compressor alignment allowable value
Volumetric flask preparation method
Solvent peak integration query method
gb/t34619
gb 34619
gb/34619

《GB/T 34619-2017容积式制冷剂压缩机容积流量试验方法》由TC238(全国冷冻空调设备标准化技术委员会)归口,主管部门为中国机械工业联合会。


Introduction

GB/T 34619—2017 Standard Overview

This standard specifies in detail the volume flow test method for positive displacement refrigerant compressors, and is applicable to single-stage positive displacement refrigerant compressors and compressor units. The standard gives clear requirements from test conditions, instruments and equipment, data processing to test reports, providing a unified technical specification for the industry.


Test conditions and requirements

Project Specific requirements
Test system sealing Ensure that the system is sealed, clean and leak-free.
Test gas requirements Use dry air or nitrogen, which has been strictly dried.
Measurement point location The suction and exhaust measurement points are 0.3m/0.15m straight pipe sections from the outside of the stop valve or the end of the pipe mouth.

Analysis of key instruments and equipment

Temperature measuring instrument:Including glass mercury thermometer, thermocouple, etc., with an accuracy requirement of ±0.1°C.

Pressure measuring instrument:Such as spring tube pressure gauge, the absolute pressure or differential pressure reading accuracy is ±1%.

Flow measuring instrument:Using nozzle, orifice plate or venturi tube, etc., the accuracy is ±2% of the measured flow.


Professional terms and practical applications

Positive Displacement Refrigerant Compressors Units

Refers to a unit consisting of a compressor, a prime mover and other accessories, used to compress refrigerant vapor. In practical applications, it is necessary to ensure that the unit operates under rated conditions to achieve optimal efficiency.


Comparative analysis of standard frameworks

Dimensions GB/T 34619—2017 Internationally accepted standards
Test conditions Clearly stipulates the test environment, gas requirements, etc. Basically consistent with relevant ISO standards.
Measurement accuracy Temperature: ±0.1°C; Pressure: ±1%; Flow: ±2%. International general requirements are similar, but some parameters are more stringent.
Data processing The five-time measurement average method is used to ensure data reliability. International standards mostly use the same method.

Implementation suggestions

  1. Equipment selection:High-precision instruments that meet the requirements of the standards are preferred to ensure measurement accuracy.
  2. Staff training:Systematic training is conducted for test personnel to master the standard terms and practical operation points.
  3. Data recording:Test parameters are recorded strictly in accordance with standard requirements to ensure traceability.
  4. Regular calibration: Regularly calibrate the instruments and equipment to ensure that the measurement accuracy meets the requirements.

Sample only — not a preview of GB/T 34619-2017