Introduction
GB/T 34619—2017 Standard Overview
This standard specifies in detail the volume flow test method for positive displacement refrigerant compressors, and is applicable to single-stage positive displacement refrigerant compressors and compressor units. The standard gives clear requirements from test conditions, instruments and equipment, data processing to test reports, providing a unified technical specification for the industry.
Test conditions and requirements
| Project | Specific requirements |
|---|---|
| Test system sealing | Ensure that the system is sealed, clean and leak-free. |
| Test gas requirements | Use dry air or nitrogen, which has been strictly dried. |
| Measurement point location | The suction and exhaust measurement points are 0.3m/0.15m straight pipe sections from the outside of the stop valve or the end of the pipe mouth. |
Analysis of key instruments and equipment
Temperature measuring instrument:Including glass mercury thermometer, thermocouple, etc., with an accuracy requirement of ±0.1°C.
Pressure measuring instrument:Such as spring tube pressure gauge, the absolute pressure or differential pressure reading accuracy is ±1%.
Flow measuring instrument:Using nozzle, orifice plate or venturi tube, etc., the accuracy is ±2% of the measured flow.
Professional terms and practical applications
Positive Displacement Refrigerant Compressors Units
Refers to a unit consisting of a compressor, a prime mover and other accessories, used to compress refrigerant vapor. In practical applications, it is necessary to ensure that the unit operates under rated conditions to achieve optimal efficiency.
Comparative analysis of standard frameworks
| Dimensions | GB/T 34619—2017 | Internationally accepted standards |
|---|---|---|
| Test conditions | Clearly stipulates the test environment, gas requirements, etc. | Basically consistent with relevant ISO standards. |
| Measurement accuracy | Temperature: ±0.1°C; Pressure: ±1%; Flow: ±2%. | International general requirements are similar, but some parameters are more stringent. |
| Data processing | The five-time measurement average method is used to ensure data reliability. | International standards mostly use the same method. |
Implementation suggestions
- Equipment selection:High-precision instruments that meet the requirements of the standards are preferred to ensure measurement accuracy.
- Staff training:Systematic training is conducted for test personnel to master the standard terms and practical operation points.
- Data recording:Test parameters are recorded strictly in accordance with standard requirements to ensure traceability.
- Regular calibration: Regularly calibrate the instruments and equipment to ensure that the measurement accuracy meets the requirements.