GB/T 34856-2017 in English
VALIDCleaning products―Determination of triclocarban
- Issued on:2017-11-01
- Implemented on:2018-05-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$68.00
《GB/T 34856-2017洗涤用品 三氯卡班含量的测定》由607(中国轻工业联合会)归口,主管部门为中国轻工业联合会。
Introduction
GB/T 34856—2017 Standard Interpretation
GB/T 34856—2017 is my country's first standard for the determination of triclocarban content in detergents, aiming to standardize industry testing methods and ensure product quality and safety.
Background of Standard Formulation
| Dimensions | Content |
|---|---|
| Drafting Basis | Follow GB/T1.1-2009 and combine with the actual needs of the industry. |
| Responsible unit | National Technical Committee for Standardization of Surfactants and Detergents (SAC/TC 272) |
| Drafting unit | China Daily Chemical Industry Research Institute, Beijing Reward Daily Chemical Co., Ltd., etc. |
Technical requirements and method principles
This standard specifies the method for determining the content of triclocarban using high performance liquid chromatography (HPLC), and its core steps include sample preparation, solution filtration and chromatographic analysis. The following are the key points:
- Sample preparation: Weigh 0.5~1.0g of sample, extract with methanol ultrasonically and then make up the volume.
- Chromatographic conditions: C₁₈ reverse phase column, mobile phase is 70% methanol + 30% water, flow rate is 1.0mL/min, detection wavelength is 264nm.
- Quantitative method: External standard method, calculation formula is shown in formula (1). $$ X={\frac{c\times V\times1000}{m}} $$ Where, \( c \) is the sample solution concentration, \( V \) is the fixed volume, and \( m \) is the sample mass.
Comparative analysis of standards
| Dimensions | Content | Interpretation |
|---|---|---|
| Scope of application | Soap, hand sanitizer and other cleaning products | Widely used in the field of daily chemical products to ensure product quality and safety. |
| Detection method | High performance liquid chromatography | High sensitivity, high accuracy, suitable for trace analysis. |
| Precision requirements | The deviation between two determination results does not exceed 10% | Ensure the reliability and consistency of the test data. |
Implementation suggestions
Laboratory operation suggestions:
- Configure reagents and calibrate instruments in strict accordance with standard requirements.
- Establish complete test records to ensure data traceability.
Manufacturers’ suggestions:
- Equip with professional testing equipment and technicians.
- Regularly send samples to third-party institutions for verification and testing.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 40002-2021 in English
Sensory analysis—Service condition for the wine-tasting glass
2021-04-30 -

GB/T 44365-2024 in English
Determination of 6-methylcoumarin, dihydrocoumarin, 7-methylcoumarin, 7-methoxycoumarin, 7-ethoxy-4-methylcoumarin in toothpastes—High performance liquid chromatography
2024-08-23 -

GB/T 9985-2022 in English
Detergents for hand dishwashing
2022-12-30 -

GB/T 16801-2013 in English
Determination of Antistatic Performance for Fabric Conditioners
2013-12-31 -

GB/T 26388-2011 in English
Determination of dioxane residues in surfactants—Gas chromatographic method
2011-05-12 -

GB/T 34855-2017 in English
Hand cleaner
2017-11-01 -

GB/T 21241-2022 in English
Toilet bowl and ceramic tile cleansers
2022-12-30 -

GB/T 35759-2017/XG1-2023 in English
Metal cleaner,includes Amendment 1
2023-12-28 -

GB 9985-2000/XG2-2008 in English
Detergents for Hand Dishwashing
2000-11-21