Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
dust removal key maintenance maintenance personnel half-year/annual gripper system calibration heavy-duty gas turbine industry navigation areas
GB/T 34933-2017 in English

GB/T 34933-2017 in English

VALID

Technical code for combiner box test of photovoltaic power station

  • Issued on:2017-11-01
  • Implemented on:2018-05-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $250.00
$243.00
Standard No: GB/T 34933-2017
Document status: VALID
Title in English: Technical code for combiner box test of photovoltaic power station
Title in Chinese: 光伏发电站汇流箱检测技术规程
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2017-11-01
Implemented on: 2018-05-01
ICS Classification: 27.160-Solar energy engineering
Professional Classification: GB-National Standard
Related Topics: Photovoltaic
monitoring station box
Technical Airflow Detection
Light test current
Light test current
Volt-ampere + detection limit
Photoelectric current measurement
High-quality photovoltaic power generation
Light path box
Photoelectric box operation process
PV
Optical Detection Technology
Molecular detection technology flow cytometry
Streamline detection process
Detection with multispectral techniques
Measurement dimension photoelectric technology
Spectral Cytometry
Photovoltaic power station
lightning current, photovoltaic
GBT34933
GB/T 34933-2017
Photovoltaic confluence equipment
Photovoltaic power station power control capability testing technical regulations
Photovoltaic power station combiner box testing technical regulations
Regulations for Technical Supervision of Combiner Box Inverters in Photovoltaic Power Stations
Power Station Engineering 5161
Photovoltaic power plant adaptive mobile detection device technology
Differential and evaporative light detector detection
Photovoltaic power station irradiator
Photovoltaic power station ground resistance test method
Photovoltaic testing specifications
UAV system detection technology for photovoltaic power stations
Photovoltaic power station energy efficiency testing technology methods
Flow cytometry technology standardization
Dual spectrum detection technology
About photovoltaic combiner box
Chemiluminescence detection technology
Photovoltaic power station environmental monitor
gb/t34933-2017
China Power Investment Corporation Photovoltaic Power Station Photovoltaic Enterprise
gbt34933
gb/t34933

《GB/T 34933-2017光伏发电站汇流箱检测技术规程》由524(中国电力企业联合会)归口,主管部门为中国电力企业联合会。


Introduction

Interpretation of GB/T 34933—2017 Technical Specification for Inspection of Combiner Boxes in Photovoltaic Power Stations

Standard dimensions Technical requirements Test methods Compliance assessment
Basic environmental conditions Temperature range: $15^\circ C \sim 35^\circ C$, humidity range: $45\% \sim 75\%$, air pressure range: $86~kPa \sim 106~kPa$ The environmental test chamber simulates different climatic conditions and uses temperature and humidity sensors for monitoring. Comply with GB/T2423 series environmental test standards
Testing equipment Ground continuity tester, arc generator, data acquisition device, etc. Calibrate the accuracy of the equipment to ensure that the measurement error is within the allowable range. The equipment complies with the requirements of GB/T28030 and GB/T20840 series standards

Explanation of professional terms and practical application cases

Photovoltaic string (PV string): In a photovoltaic power generation system, several photovoltaic modules are connected in series to form a circuit unit with a certain DC output. For example, in a rooftop photovoltaic power generation system, 6-10 photovoltaic modules are usually connected in series to form a string.

Electrical clearance and creepage distance: This is a key indicator to measure the insulation performance of electrical equipment. For example, in the design of the combiner box, the minimum electrical clearance of the equipment with a rated voltage of $1000~V$ should be no less than 18mm, and the creepage distance should be no less than 31mm.

Background of Standard Formulation and Analysis of Technology Evolution

GB/T 34933-2017 was formulated against the background of the rapid development of China's photovoltaic power generation industry. With the advancement of photovoltaic technology and the expansion of system scale, higher requirements are put forward for the safety and reliability of combiner boxes. This standard combines advanced domestic and foreign detection methods to fill the gap in this field in China.

Implementation Suggestions

  1. Training and Standardization Management: Conduct systematic training for technical personnel to ensure that they are familiar with the standard content and detection process. Establish a complete equipment ledger management system.
  2. Testing Equipment Configuration: Equipped with test instruments that meet the accuracy requirements, calibrated and maintained regularly.
  3. Risk prevention and control: In high altitude areas, special attention should be paid to the correction of electrical clearance and insulation performance to avoid safety hazards caused by environmental factors.
  4. Continuous optimization: Pay attention to industry technology trends and update testing standards and methods in a timely manner.

For more details, please refer to the test report template and arc generator structure requirements in the appendix.

Sample only — not a preview of GB/T 34933-2017
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend