GB/T 35011-2018 in English
VALIDMicrowave circuits—Measuring methods for voltage controlled oscillater
- Issued on:2018-03-15
- Implemented on:2018-08-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$243.00
《GB/T 35011-2018微波电路 压控振荡器测试方法》由TC599(全国集成电路标准化技术委员会)归口,主管部门为工业和信息化部(电子)。
Introduction
Introduction
GB/T 35011—2018 "Test Methods for Voltage Controlled Oscillators in Microwave Circuits" is an important standard in China's electronic technology field, which aims to standardize the main electrical parameter test process of voltage-controlled oscillators (VCOs). This article will conduct an in-depth analysis from the aspects of standard background, technical framework, interpretation of key parameters and implementation suggestions.
Background and significance of standard formulation
With the rapid development of microwave communication and radio frequency technology, voltage-controlled oscillators, as core components, play an important role in wireless communication, radar systems and other fields. In order to ensure product quality and technical consistency, this standard came into being. It specifies in detail the test methods for various performance indicators of VCOs, filling the gap in related fields in China.
Comparison of standard frameworks
| Parameter name | GB/T 35011—2018 | International similar standards |
|---|---|---|
| Frequency range | Specifies the minimum and maximum operating frequencies | Consistent with IEEE 1596.2 standard |
| Output power | Test power flatness and temperature coefficient | Meets ETSI specification requirements |
| Electrically adjustable sensitivity | Introduces linearity indicator evaluation | Superior to other national standards (such as MIL-STD-1354) |
Professional terms and practical application cases
Frequency pulling (Δf_{id}):The change in the oscillator output frequency under load mismatch. For example, in a communication system, if the RF front end is not properly matched, it may cause the VCO frequency to shift, affecting the signal transmission quality.
Phase noise (L(fm)):A key indicator to measure the purity of an oscillator. In modern wireless communications, high-order modulation technology has extremely high requirements for phase noise, and exceeding the standard will lead to an increase in bit error rate.
Implementation suggestions
- Test equipment calibration:Ensure the measurement validity period of instruments such as spectrum analyzers and signal source analyzers, and calibrate them regularly.
- Environmental control:Test under standard temperature and humidity conditions to reduce the influence of external interference factors.
- Test record management: Establish a complete test file, including parameter settings, measurement data and analysis reports, for traceability and improvement.

Loading PDF document...