GB/T 35212.1-2017 in English
VALIDAnalysis and evaluation methods of gas and solution and desulfurization decarbonization and sulfur recovery for natural gas treating plant-Part 1:Gas and solution analysis
- Issued on:2017-12-29
- Implemented on:2018-07-01
- File Format:PDF
- Delivery:Via email within 5 business days
$815.00
《GB/T 35212.1-2017天然气处理厂气体及溶液分析与脱硫、脱碳及硫磺回收分析评价方法 第1部分:气体及溶液分析》由TC244(全国天然气标准化技术委员会)归口,主管部门为国家标准化管理委员会。
Introduction
Analysis of the core content of the standard
| Analysis items | Method principle | Determination range | Reference standard |
|---|---|---|---|
| Hydrogen sulfide content | Iodometric method/methylene blue method/gas chromatography | 0.05%-100% | GB/T 11060 series |
| Carbon dioxide content | Potassium hydroxide absorption subtraction method | 0.1%-100% | Chapter 6 of this standard |
| Sulfur mist determination | Filtration weighing method | 0.5-10g/m³ | Chapter 10 of this standard |
Evolution of key technologies
This standard integrates traditional chemical analysis methods with modern instrumental analysis methods:
- Chemical method: retain the classic iodine titration (hydrogen sulfide) and neutralization titration (carbon dioxide) to ensure the reliability of basic data
- Instrumental method: newly added gas chromatography (process gas analysis) and ultraviolet fluorescence method (total sulfur determination) to improve analysis efficiency
Typical application cases
Determination of low concentration hydrogen sulfide in purified gas
A natural gas purification plant adopts Molybdenum blue spectrophotometry (Chapter 5.2) Monitor 0-25mg/m³ hydrogen sulfide in purified gas:
- Prepare ammonium molybdate colorimetric solution (3.4.1.10)
- Select sampling volume according to Table 1 (1-10L)
- Control the absorption flow rate at 200-300mL/min
- Measure absorbance at a wavelength of 600nm
The relative standard deviation of this method is ≤10% (when H₂S>5mg/m³)
Implementation suggestions
Key points for safety protection
- All hydrogen sulfide analyses must comply with SY/T 6137 safety regulations
- Positive pressure respirators are required for acid gas sampling
- The laboratory should be equipped with H₂S alarm device
Quality control measures
- Monthly calibration of standard solution (Clause 3.4.2)
- Aging of chromatographic column every 3 months (8.4.3.4)
- Relative deviation control of parallel samples (repeatability requirements of each chapter)

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 18376.3-2015 in English
Grades of cemented carbide—Part 3: Grades of cemented carbide for wear parts
2015-12-10 -

GB/T 8492-2024 in English
Heat-resistant cast steels and alloys for general applications
2024-04-25 -

GB/T 15967-2024 in English
Specifications for digital aerial photogrammetric mapping of 1:500 1:1000 1:2000 topographic maps
2024-05-28 -

GB/T 35515-2017 in English
Chemicals—Fish assay for oestrogenic and androgenic activity, and aromatase inhibition
2017-12-29 -

GB/T 100-1986 in English
Slotted countersink head wood screws
1986-07-02 -

GB/T 39356-2020 in English
Determination of total nickel,total cobalt,total selenium,total vanadium,total stibium,total thallium in fertilizers—Inductively coupled plasma optical emission spectroscopy
2020-11-19 -

GB/T 15296-1994 in English
General specification of equipments for transportable satellite communication earth station
1994-01-02 -

GB 8109-2023 in English
Wheeled fire extinguishers
2023-12-28 -

GB/T 6108.3-2003 in English
Basic dimensions of winding wires - Part 3: Dimensions of conductors of insulated rectangular copper winding wires
2003-06-24 -

GB 34655-2017 in English
Specifications for extinguishing equipment arrangement in bus
2017-10-14