Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
long-term shelter internal air pressure public shelter medium-term shelter indoor air pressure practical application cases positive pressure shelter major toxic gas leakage terminology concerning fire test sy series miniature permanent magnetic direct current servo motors scopethis standard type cs0524 gaas
GB/T 35621-2017 in English

GB/T 35621-2017 in English

VALID

General technical requirements of public shelter in major toxic gas leakage accident

  • Issued on:2017-12-29
  • Implemented on:2018-06-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $220.00
$214.00
Standard No: GB/T 35621-2017
Document status: VALID
Title in English: General technical requirements of public shelter in major toxic gas leakage accident
Title in Chinese: 重大毒气泄漏事故公众避难室通用技术要求
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2017-12-29
Implemented on: 2018-06-01
ICS Classification: 13.200-Accident and disaster control
Chinese Classification: A90-Social and public safety in general
Professional Classification: GB-National Standard
Related Keywords: long-term shelter internal air pressure
public shelter
medium-term shelter indoor air pressure
practical application cases positive pressure shelter
major toxic gas leakage
Related Topics: leakage
major
public
gas leak
General Technical Requirements for Public Refuge Rooms in Major Poisonous Gas Leakage Accidents
GB/T35621-2017
Accident nuclear leak
GB/T 35621-2017
Exhaust gas accident
Spill accident
Spill accident
Leakage
spill, accident
GBT35621
GB/T 35621-2017
Laboratory public account

《GB/T 35621-2017重大毒气泄漏事故公众避难室通用技术要求》由TC351(全国公共安全基础标准化技术委员会)归口,主管部门为国家标准化管理委员会。


Introduction

Interpretation of the National Standard of the People's Republic of China GB/T 35621—2017

Technical Requirements and Specifications for Public Shelters in Major Toxic Gas Leakage Accidents

ew row>
Types of Shelters Functional Features Technical Parameters Applicable Scenarios
Simple Public Shelters Applicable to short-term evacuation, with moderate sealing requirements The air exchange rate is not less than the calculated minimum safety value Ordinary residential buildings or temporary emergency sites
Ordinary Public Shelters No positive pressure device, suitable for medium-term shelter Indoor air pressure is balanced with outdoor air pressureLong-term emergency place around the dangerous area
Positive pressure public shelter Dedicated fresh air system, suitable for long-term shelter Internal air pressure not less than 10Pa High-risk area or long-term emergency needs

Explanation of professional terms and practical application cases

Positive Pressure Shelter: The internal air pressure is higher than the external air pressure, and the positive pressure state is maintained by the fresh air system to prevent toxic gas infiltration. For example, the positive pressure public refuge room set up around the chemical plant can effectively protect the lives of residents in the event of a toxic gas leak.

Technical Background and Evolution Analysis

This standard is based on GB/T1.1-2009 and combines the practical experience of domestic and foreign emergency management systems. The technical requirements for positive pressure refuge rooms have absorbed international advanced experience, especially in terms of fresh air systems and sealing performance.

Sample only — not a preview of GB/T 35621-2017
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.