GB/T 35957-2018 in English
VALIDDetermination of prohibited substances cesium-137,cesium-134 in cosmetics—Gamma spectrometry
- Issued on:2018-02-06
- Implemented on:2018-09-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$78.00
《GB/T 35957-2018化妆品中禁用物质铯-137、铯-134的测定 γ能谱法》由TC257(全国香料香精化妆品标准化技术委员会)归口,TC257SC2(全国香料香精化妆品标准化技术委员会化妆品分会)执行,主管部门为中国轻工业联合会。
Introduction
Interpretation of GB/T 35957—2018 National Standard of the People's Republic of China
Determination of Cesium-137 and Cesium-134, Prohibited Substances in Cosmetics - Y-Spectrometry
Background and Significance of Standard Formulation
This standard was drafted in accordance with GB/T1.1—2009 rules, proposed by the China Light Industry Federation, and managed by the National Technical Committee for Standardization of Flavors, Fragrances and Cosmetics. The formulation of the standard fills the gap in the field of radionuclide detection methods in cosmetics in my country and provides important technical support for ensuring the safety of cosmetics.
Scope of application of the standard
This standard is applicable to the determination of Cesium-137 and Cesium-134 in powder, cream, lotion and liquid cosmetics, with a detection limit of $10~\mathrm{Bq/kg}$.
Comparative Analysis of Technical Methods
| Detection Items | Energy Spectrometry | Other Radioactive Detection Methods |
|---|---|---|
| Sensitivity | $10~\mathrm{Bq/kg}$ | - |
| Detection Time | About 10,000 seconds | - |
| Equipment Requirements | Energy Spectrometer, High-Purity Germanium Detector | Liquid Chromatography-Mass Spectrometry, etc. |
Instrument and Equipment Specifications
Spectrometer is the core equipment of this standard and must meet the following requirements:
- Coaxial high-purity germanium detector: The $1.3325~\mathrm{keV}$ $\gamma$ ray energy resolution of cobalt-60 is less than $3~\mathrm{keV}$, and the relative efficiency is higher than $15\%$.
- Shield: The equivalent lead equivalent is not less than $10~\mathrm{{cm}}$, and it is lined with multiple layers of heavy metal materials.
- The $\gamma$ spectrometer integrated background should be less than 2.5 counts/second.
Standard Implementation Recommendations
Case Analysis: Application of Standards in Actual Testing
A cosmetics company tested a batch of emulsion products according to this standard method. The results show that this method has high sensitivity and accuracy, and the operation process is relatively simple. It is recommended that enterprises should:
- Equip professional technicians for sample preparation and instrument operation.
- Regularly calibrate the equipment to ensure measurement accuracy.
- Establish a complete test record and data analysis system.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 22728-2008 in English
Determination of butylated hydroxyanisole (BHA) and butylated hydroxytoluene (BHT) in cosmetics—High performance liquid chromatography
2008-12-31 -

GB/T 13531.1-2008 in English
General methods on determination of cosmetics—Determination of pH
2008-12-28 -

GB/T 32986-2016 in English
Determination of nine anti-allergy drugs in cosmetics一LC-MS/MS
2016-10-13 -

GB/T 44428-2024 in English
Determination of cannabidiol and tetrahydrocannabinol in cosmetics—Liquid chromatography tandem mass spectrometry
2024-08-23 -

GB/T 29680-2026 in English
Facial washing milk(cream,liquid,mousse,gel,powder)
2026-02-27 -

GB/T 26513-2023 in English
Lip moisturizer(gel,cream)
2023-03-17