GB/T 37363.3-2020 in English
VALIDDetermination of biocides content of coating materials—Part 3:Determination of triclosan content
- Issued on:2020-11-19
- Implemented on:2021-10-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$146.00
《GB/T 37363.3-2020涂料中生物杀伤剂含量的测定 第3部分:三氯生含量的测定》由TC5(全国涂料和颜料标准化技术委员会)归口,TC5SC1(全国涂料和颜料标准化技术委员会基础分会)执行,主管部门为中国石油和化学工业联合会。
Introduction
Technical Background of the Standard
As environmental regulations become increasingly stringent, the control of biocides in coatings has become an industry focus. Triclosan is a commonly used preservative, and its residue may cause environmental and health risks. As part of the GB/T 37363 series, this standard is aligned with the ISO method and fills the gap in the domestic triclosan testing standard in the coatings field.
Comparison of core detection methods
| Dimension | Liquid chromatography (LC) | LC-MS/MS coupling |
|---|---|---|
| Detection limit | 5 mg/kg | 1 mg/kg |
| Sample amount | About 1g | About 0.5g |
| Qualitative method | Retention time | Retention time + characteristic ions |
| Equipment cost | Lower | Higher |
Key Operation Points
Sample Pretreatment Specifications
Solid samples need to be filtered through a stainless steel metal sieve (pore size 0.55mm). During ultrasonic extraction, the water bath temperature must be controlled to ≤30℃, and the centrifuge chamber temperature must be monitored simultaneously. The methanol extract needs to be filtered through a microporous membrane (0.45μm for LC and 0.22μm for LC-MS/MS).
Standard Curve Verification
The LC method requires a linear determination coefficient R²>0.999, and the LC-MS/MS method requires >0.995. During the experiment, it was found that when a certain laboratory used Agilent 1260 HPLC, the R² of the standard curve was only 0.997, and the gradient elution program or chromatographic column activity needed to be checked.
Technology Evolution Analysis
Compared with the 2015 draft for comments, the 2020 official version has the following major improvements:
1. Add LC-MS/MS as an arbitration method
2. Clarify the centrifugal temperature control requirements
3. Supplement ammonium acetate as a mobile phase modifier
Implementation Recommendations
- For export product testing, LC-MS/MS is preferred to meet the requirements of EU REACH regulations
- Regularly verify the column efficiency of the reversed-phase chromatographic column and replace it when the theoretical plate number decreases by 15%
- Establish an internal laboratory quality control chart to monitor the recovery rate (recommended range 85-115%)

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 45973-2025 in English
Paints and varnishes—Scratch test using a spring-loaded pen
2025-08-01 -

GB/T 6739-2022 in English
Paints and varnishes—Determination of film hardness by pencil test
2022-12-30 -

GB/T 16995-1997 in English
Determination of gel time of thermosetting powder coatings at a given temperature
1997-09-26 -

GB/T 25266-2010 in English
Paints—Determination of the particle size distribution of paint fillers by the ANDREASEN pipette method
2010-09-26 -

GB/T 33327-2016 in English
Ultraviolet curable coatings-Assessment of the storage stability
2016-12-13 -

GB/T 26323-2010 in English
Paints and varnishes—Determination of resistance to filiform corrosion on aluminium and aluminium alloys
2011-01-14 -

GB/T 11185-2009 in English
Paints and varnishes—Bend test(conical mandrel)
2009-06-02 -

GB/T 30646-2014 in English
Determination of phthalate plasticizers content in coatings―Gas chromatography/mass spectrometry method
2014-12-31