Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
photovoltaic grid-connected inverter gb/t photovoltaic grid-connected inverter photovoltaic grid-connected inverter nb/t testing code 37409-2019 testing specification equipment- self-propelled road widener introductionthis standard cherry introduction interpretation ophthalmic optical instruments scopethis standard
GB/T 37409-2019 in English

GB/T 37409-2019 in English

VALID

Testing specification for photovoltaic grid-connected inverter

  • Issued on:2019-05-10
  • Implemented on:2019-12-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $550.00
$534.00
Standard No: GB/T 37409-2019
Document status: VALID
Title in English: Testing specification for photovoltaic grid-connected inverter
Title in Chinese: 光伏发电并网逆变器检测技术规范
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2019-05-10
Implemented on: 2019-12-01
ICS Classification: 27.160-Solar energy engineering
Chinese Classification: F12-Solar energy
Professional Classification: GB-National Standard
Related Keywords: photovoltaic grid-connected inverter gb/t
photovoltaic grid-connected inverter
photovoltaic grid-connected inverter nb/t
testing code
37409-2019 testing specification
Related Topics: Photovoltaic
Evaporative Photodetector Detector
evaporative photodetector peak
No reverse current grid-connected inverter device
Used Evaporative Light Detectors
Volt-ampere + detection limit
Luminaire inspection
Photovoltaic Simulator
Building photovoltaic system without reverse current grid-connected inverter device
merge after detection
Chromatographic Detector/UV Detector/Evaporative Light Detector
High-quality photovoltaic power generation
Evaporative Photodetector 6
millivolt generator
Evaporative Photodetector 65
Other Evaporative Photodetectors
Other Evaporative Photodetectors
Evaporative Photodetector Peak Front
light detector detector
PV
Optical Detection Technology
Measurement dimension photoelectric technology
UV detectors and evaporative light detectors
GBT37409
Grid-connected test procedures
Grid-connected testing procedures for household photovoltaic power generation systems
Regulations for Technical Supervision of Combiner Box Inverters in Photovoltaic Power Stations
Technical Requirements for Electromagnetic Compatibility Testing of Inverters in Photovoltaic Power Stations
Photovoltaic power station inverter power quality testing technical regulations
Photovoltaic Power Station Inverter Voltage and Frequency Response Testing Technical Regulations
Technical Requirements for Inverter Efficiency Testing in Photovoltaic Power Stations
The difference between differential detector and evaporative light detector
Detection principle of evaporative light detector
Aotai evaporation light detector elsd6000
Differential and evaporative light detector detection
Inverter connected to the grid to generate electricity
The latest technical specifications for transformer oil testing
Photovoltaic testing specifications
French inverter grid connection
Photovoltaic power generation engineering inverter modeling technology
Transformer oil sample testing and detection technology
Photovoltaic inverter numbering specifications
Photovoltaic inverter industry
Dual spectrum detection technology
Grid-connected switch detection
Photovoltaic inverter connected to the grid in Germany
China inverter grid connection
China photovoltaic inverter safety
Chemiluminescence detection technology
Photovoltaic inverter national mandatory
Network inverter execution
Network type inverter

《GB/T 37409-2019光伏发电并网逆变器检测技术规范》由524(中国电力企业联合会)归口,主管部门为中国电力企业联合会。


GB/T 37409-2019 Testing specification for photovoltaic grid-connected inverter

1 Scope

This standard specifies the technical requirements for the testing of appearance and structure, environmental adaptability, safety performance, electrical performance, communication, electromagnetic compatibility, efficiency, marking durability, packaging, transportation and storage of photovoltaic grid-connected inverters.

This standard is applicable to the type test of photovoltaic grid-connected inverters, and may serve as a reference for the factory test and the field test thereof.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

GB/T 3768 Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Survey method using an enveloping measurement surface over a reflecting plane
GB/T 4208 Degrees of protection provided by enclosure (IP code)
GB 4824 Industrial, scientific and medical (ISM) radio-frequency equipment - Disturbance characteristics - Limits and methods of measurement
GB/T 4857.10 Packaging - Basic tests for transport packages - Part 10: Sinusoidal vibration test method using at variable vibration frequency
GB/T 6461 Methods for corrosion testing of metallic and other inorganic coatings on metallic substrates - Rating of test specimens and manufactured articles subjected to corrosion tests
GB/T 9254 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
GB/T 12325 Power quality - Deviation of supply voltage
GB/T 14549 Quality of electric energy supply - Harmonics in public supply network
GB/T 15543 Power quality - Three-phase voltage unbalance
GB/T 15945 Power quality - Frequency deviation for power system
GB/T 16404 Acoustics - Determination of sound power levels of noise sources using sound intensity - Part 1: Measurement at discrete points
GB/T 16935.1 Insulation coordination for equipment within low-voltage systems - Part 1: Principles requirements and tests
GB/T 17626.2 Electromagnetic compatibility - Testing and measurement techniques - Electrostaic discharge immunity test
GB/T 17626.3 Electromagnetic compatibility - Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
GB/T 17626.4 Electromagnetic compatibility - Testing and measurement techniques - Electrical fast transient/burst immunity test
GB/T 17626.5 Electromagnetic compatibility - Testing and measurement techniques - Surge immunity test
GB/T 17626.6 Electromagnetic compatibility - Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
GB/T 17626.8 Electromagnetic compatibility - Testing and measurement techniques - Power frequency magnetic field immunity test
GB/T 17627.2 High-voltage test techniques for low-voltage equipment - Part 2: Measuring system and test equipment
GB 20840.2 Instrument transformers - Part 2: Additional requirements for current transformers
GB 20840.3 Instrument transformers - Part 3: Additional requirements for inductive voltage transformers
GB/T 37408 Technical requirements for photovoltaic grid-connected inverter
NB/T 32008 Testing code for power quality of inverters used in photovoltaic power station
NB/T 32010 The anti-islanding testing code for inverter of utility-interconnected photovoltaic power station
NB/T 32032 Technical code for inverter efficiency testing of photovoltaic power station

3 Terms and definitions

For the purposes of this document, the following terms and definitions apply.

3.1
primary power-frequency regulating coefficient
Kf
ratio representing the variation in inverter active power to that in system frequency in case of frequency deviation in the system, calculated using Equation (1)

(1)

where,

ΔP——the variation in the output active power of the inverter, kW;

PN——the rated active power of the inverter, kW;

Foreword ii
1 Scope
2 Normative references
3 Terms and definitions
4 Basic requirements
5 Appearance and structure inspection
6 Environmental adaptability test
7 Safety performance test
8 Electrical performance test
9 Communication test
10 EMC test
11 Efficiency test
12 Marking durability test
13 Packaging, transportation and storage
Annex A (Normative) Contact probe
Annex B (Normative) Touch current tester
Annex C (Normative) Response time and error of power control
Annex D (normative) Methods for judgment and calculation of reactive current injection

Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend