VALIDReclaimed water quality—Determination of mercury—Mercury analyzer method
- Issued on:2019-08-30
- Implemented on:2020-07-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$88.00
《GB/T 37906-2019再生水水质 汞的测定 测汞仪法》由TC63(全国化学标准化技术委员会)归口,TC63SC5(全国化学标准化技术委员会水处理剂分会)执行,主管部门为中国石油和化学工业联合会。
Introduction
1. Background and purpose of the standard
The National Standard of the People's Republic of China GB/T 37906-2019 "Determination of mercury in recycled water quality - mercury instrument method" is to standardize the determination method of mercury content in recycled water and ensure the accuracy and reliability of the test results. This standard is applicable to the determination of mercury content in recycled water, surface water and wastewater, with a determination range of $0.1~\mu\mathrm{g}/\mathrm{L}{\sim}100~\mu\mathrm{g}/\mathrm{L}$.
2. Comparison of standard frameworks
| Standard dimensions | Recycled water quality | Surface water | Wastewater |
|---|---|---|---|
| Measurement range | $0.1~\mu\mathrm{g}/\mathrm{L}{\sim}100~\mu\mathrm{g}/\mathrm{L}$ | $0.1~\mu\mathrm{g}/\mathrm{L}{\sim}100~\mu\mathrm{g}/\mathrm{L}$ | $0.1~\mu\mathrm{g}/\mathrm{L}{\sim}100~\mu\mathrm{g}/\mathrm{L}$ |
| Dilution requirements | Dilution is required when the mass concentration exceeds $100~\mu\mathrm{g/L}$ | Same as above | Same as above |
| Applicable instruments | Mercury analyzer | Mercury analyzer | Mercury analyzer |
3. Determination method and technical analysis
This standard adopts the catalytic pyrolysis cold atomic absorption mercury analyzer method. After the sample is dried and thermally decomposed, the gaseous product is transported to the catalytic furnace by oxygen, halogens, nitrogen oxides and sulfur oxides are captured, and the remaining products are brought into the gold amalgam adsorption device. After sufficient heating, mercury vapor is released, and oxygen brings the mercury vapor into the absorption cell, and the absorbance of mercury is measured at a wavelength of $253.7\mathrm{nm}$.
4. Implementation suggestions
Instrument selection:It is recommended to use a mercury analyzer that meets the requirements of the standard, and ensure that it is equipped with a thermal decomposition furnace, a catalytic furnace, a cold atomic absorption spectrometer and a data processing system.
Sample collection and storage:Water quality samples should be collected and stored in accordance with the provisions of GB/T5750.2 to ensure that no mercury loss or interference occurs during the transportation and storage of the samples.
Test condition optimization: Debug the best test conditions according to the instrument manual and set the parameters according to Table 1. For example, the drying temperature is recommended to be set to $200℃$ and the decomposition temperature to be set to $700℃$.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 32107-2015 in English
Code for recirculating cooling water treatment by ozone
2015-10-09 -

GB/T 37907-2019 in English
Reclaimed water quality—Determination of sulfide and cyanide—Ion chromatography
2019-08-30 -

GB/T 33086-2016 in English
Water treatment chemical一Determination of arsenic and mercury- Atomic fluorescence spectrometry
2016-10-13 -

GB/T 6911-2017 in English
Determination of sulfate in water for industrial circulating cooling system and boiler
2017-09-07