Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
standard technical dimensions general requirements additional requirements general specification ultrasonic level meters ultrasonic levelmeter introduction analysis explosion-proof type emc immunity electrostatic discharge level b must polyester fiber scopethis standard building hoists axle load control
GB/T 38615-2020 in English

GB/T 38615-2020 in English

VALID

General specification of ultrasonic levelmeter

  • Issued on:2020-04-28
  • Implemented on:2020-11-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $220.00
$214.00
Standard No: GB/T 38615-2020
Document status: VALID
Title in English: General specification of ultrasonic levelmeter
Title in Chinese: 超声波物位计通用技术条件
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2020-04-28
Implemented on: 2020-11-01
ICS Classification: 25.040.40-Industrial process measurement and control
Chinese Classification: N10-Industrial automation and control device in general
Professional Classification: GB-National Standard
Related Keywords: standard technical dimensions general requirements additional requirements
general specification
ultrasonic level meters
ultrasonic levelmeter introduction analysis
explosion-proof type emc immunity electrostatic discharge level b must
Related Topics: ultrasound in english
Ultrasonic principle
Ultrasonic use
Uses of Ultrasound
Ultrasonic application
Ultrasonic use
Ultrasonic principle
Ultrasound as
Level gauge
Universal Ultrasonic Transducer
Where is ultrasound used??
Ultrasonic components
Ultrasonic is suitable for
What are the applications of ultrasound
Ultrasound is used in addition to
Which use ultrasound
Classification of ultrasound
What is ultrasound used for
Ultrasonic classification
Ultrasonic accessories
those with ultrasound
GBT38615
GB/T 38615-2020
ultrasound
Ultrasonic level gauge
Execution of level gauge
Ultrasonic extraction of plant juices
Reliability of ultrasonic positioning
Ultrasonic level meter power
Ultrasonic Level Gauge Specification
Ultrasonic liquid level gauge verification
National implementation of ultrasonic level meter
Ultrasonic level meter industry
gb/t 38615-2020
Ultrasonic transducer design

《GB/T 38615-2020超声波物位计通用技术条件》由TC124(全国工业过程测量控制和自动化标准化技术委员会)归口,TC124SC2(全国工业过程测量控制和自动化标准化技术委员会控制仪表及装置、工业控制计算机系统分会)执行,主管部门为中国机械工业联合会。


Introduction

Analysis of the core content of the standard

Technical dimensions General requirements Additional requirements for explosion-proof type
Protection level ≥IP54(indoor)/IP65(outdoor) Must comply with GB 3836 series standards
Operating temperature -20℃~+55℃ Special provisions according to explosion-proof type
EMC immunity Electrostatic discharge level B Must pass the encapsulation/explosion-proof test

Detailed explanation of key technical indicators

Take the 30m range level meter as an example:

  • Blind zone requirement: ≤0.7m (specified in Table 3 of the standard)
  • Beam angle selection: 4°~14° can be customized, ≤8° is recommended for narrow space
  • Class 0.5 accuracy: must meet the inaccuracy of ±0.5% of the range

Implementation and application recommendations

Selection guide

In corrosive environments, a split structure should be selected to separate the electronic unit from the transducer; a surge protector should be configured in situations with strong electromagnetic interference.

Installation specifications

Note when installing the flange:

  1. Avoid turbulent areas at the feed inlet
  2. Ensure there are no fixed obstacles within the beam angle
  3. Four-wire power supply lines must be routed independently

Background of standard evolution

For the first time, this standard includes the EMC requirements (such as electrical fast transient pulse group immunity) of ultrasonic level meters into mandatory testing items, reflecting the higher requirements for instrument reliability in the era of Industry 4.0. Major improvements compared to the old version:

  • Added digital signal output specifications
  • Refined the explosion-proof classification (Ga-level EPL)
  • Clarified the starting drift test method

Sample only — not a preview of GB/T 38615-2020
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend

  • GB/Z 192.1-2026 in English

    GB/Z 192.1-2026 in English

    Industrial process control devices—Thermographic cameras—Part 1: Metrological characterization

    2026-07-02
  • GB/T 44449-2024 in English

    GB/T 44449-2024 in English

    Industrial automation systems and integration—Formal semantic models for the configuration of global production networks

    2024-09-29
  • GB/Z 174.3-2026 in English

    GB/Z 174.3-2026 in English

    Industrial-process measurement, control and automation—Smart manufacturing—Part 3:Challenges for cybersecurity

    2026-04-30
  • GB/T 777-2008 in English

    GB/T 777-2008 in English

    Analogue pneumatic signal for industrial-process measurement and control instruments

    2008-06-30
  • GB/T 40209-2021 in English

    GB/T 40209-2021 in English

    General modelling principle for integration based on information model about manufacturing equipment

    2021-05-21