GB/T 39285-2020 in English
VALIDMethod for chemical analysis of palladium compounds—Determination of chlorine content—Ion chromatography
- Issued on:2020-11-19
- Implemented on:2021-10-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$117.00
《GB/T 39285-2020钯化合物分析方法 氯含量的测定 离子色谱法》由TC243(全国有色金属标准化技术委员会)归口,TC243SC5(全国有色金属标准化技术委员会贵金属分会)执行,主管部门为中国有色金属工业协会。
Introduction
Analysis of the core content of the standard
This standard specifies the technical specifications for the determination of chlorine content in tungsten compounds by ion chromatograph, focusing on two types of samples:
| Sample type | Pretreatment method | Determination range (w/%) | Key reagents |
|---|---|---|---|
| Tungsten nitrate, tungsten sulfate | Hydrazine hydrate reduction method | 0.00100-0.0300 | Hydrazine hydrate (ρ=1.03g/mL) |
| Organic tungsten compounds such as tungsten acetate | Oxygen bomb combustion method | 0.0100-0.500 | Sodium carbonate-sodium bicarbonate absorption liquid |
Technical innovation
This standard innovatively uses oxygen bomb combustion device to treat organic tungsten compounds, and achieves complete decomposition through 3.0MPa high-pressure oxygen environment, and carbonate absorption liquid can effectively capture volatile chlorine elements. Compared with traditional methods, the recovery rate is increased by about 15%.
Precision control requirements
The standard strictly stipulates the repeatability limit (r) and reproducibility limit (R):
- When the content of tungsten nitrate is 0.00899%, the repeatability limit is ≤0.00137%
- When the content of tungsten acetate is 0.0836%, the reproducibility limit is ≤0.0236%
Implementation suggestions
- Glassware needs to be pretreated with 80g/L sodium hydroxide solution for 4 hours
- It is recommended to use PVDF microporous filter membrane (0.22μm) to filter the sample
- The correlation coefficient of the working curve must be ≥0.999
Background of Standard Evolution
With the increasing purity requirements of tungsten compounds in the precious metal catalyst industry, the original method can no longer meet the needs of ppb-level chlorine detection. This standard optimizes the chromatographic conditions (eluent: 3.2mmol/L Na2CO3 + 1.0mmol/L NaHCO3) to reduce the detection limit by one order of magnitude compared with the 2005 version of the standard.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 23276-2024 in English
Method for chemical analysis of palladium compounds—Determination of palladium content—Complexometric tityation using butanedione dioxime releasing EDTA and gravimetric method
2024-09-29 -

GB/T 23514-2020 in English
Methods for chemical analysis of nuclear-grade Ag-In-Cd alloys
2020-11-19 -

GB/T 34499.1-2017 in English
Method for chemical analysis of iridium compounds - Part 1: Determination of iridium content - Electricity titration using ferrous sulfate
2017-09-29 -

GB/T 15072.6-2025 in English
Methods for chemical analysis of precious metal alloys—Part 6: Determination of iridium content
2025-08-29 -

GB/T 38744-2020 in English
Methods for chemical analysis of synergistic catalysis elements in automotive exhaust catalysis—Determination of cerium,lanthanum,praseodymium,neodymium,barium and zirconium contents—Inductively coupled plasma atomic emission spectrometry
2020-04-28 -

GB/T 34609.1-2017 in English
Method for chemical analysis of rhodium compounds - Part 1: Determination of rhodium content - Gravimetric method with hexaammine cobalt nitrate
2017-10-14