GB/T 39703-2020 in English
VALIDGuideline for the testing of corrugated DeNOx catalysts
- Issued on:2020-12-14
- Implemented on:2021-11-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$243.00
《GB/T 39703-2020波纹板式脱硝催化剂检测技术规范》由TC63(全国化学标准化技术委员会)归口,TC63SC10(全国化学标准化技术委员会化工催化剂分会)执行,主管部门为中国石油和化学工业联合会。
Introduction
Analysis of the core content of the standard
| Test category | Key indicators | Test method | Accuracy requirements |
|---|---|---|---|
| Geometric performance | Pitch/opening ratio/geometric specific surface area | Calculation using formula (1) (2) | ±0.1mm/±0.1% |
| Physical and chemical properties | Wear rate/specific surface area/pore volume | Quartz sand wear/BET method/mercury intrusion method | 0.01%/kg |
| Reaction performance | DeNOx efficiency/SO2 conversion rate | Chemiluminescence method/UV fluorescence method | ±3% relative deviation |
Technology evolution and standard background
This standard establishes a complete detection system for the first time for the special structure of corrugated plate deNOx catalyst:
- Innovatively defines exclusive parameters such as pitch (center distance between adjacent plates) and geometric specific surface area
- Introduces 10.5m/s high wind speed wear test conditions, which is closer to actual flue gas conditions
- Specifies that multi-layer catalysts must be tested in series to ensure data comparability
Detailed explanation of key detection methods
Abrasion rate test
The quartz sand abrasion method (particle size 0.300-0.425mm) is used. Test conditions:
Wind speed 10.5±0.5m/s | Abrasive agent concentration 50±5g/m³ | Test time 2h
Calculation formula: ζh=(m1-m2)/ma×100%
Activity test
Requires 30 hours of aging pretreatment, ammonia nitrogen molar ratio controlled at 1.0-1.1, and 4 consecutive tests with a relative deviation of <3% are valid
Implementation suggestions
- When testing geometric dimensions, the number of measuring points should be ≥10 and evenly distributed.
- Specific surface area testing requires vacuum degassing at 250℃ for more than 2h
- System leak testing (0.3MPa nitrogen pressure maintenance) is required for reaction performance testing.
- It is recommended to retain ≥3 units of each batch of products for quality traceability

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 31590-2025 in English
Analytical method of chemical composition for flue gas DeNOx catalysts
2025-12-02 -

GB/T 33067-2016 in English
Analysis method of chemical composition for Pd deoxidant catalyst at the middle temperature
2016-10-13 -

GB/T 31536-2015 in English
Analytical method of chemical composition for copper series arsenic removal agent at room temperature
2015-05-15 -

GB/T 38108-2019 in English
Test method for derterming chlorine capacity of alkaline earth metal-based sorbents at high temperature
2019-10-18