Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
protection objects communication relay protection device configuration relay protection devices medium voltage power supply system digital communication digital communication introduction supportability requirements sinter flue gas circulating fluidized bed semi-dry desulfurization technical specification infection control principle
GB/T 42149-2022 in English

GB/T 42149-2022 in English

VALID

Railway application—Fixed installations—Technical specification for current protection of medium voltage power supply system based on digital communication

  • Issued on:2022-12-30
  • Implemented on:2023-07-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $210.00
$204.00
Standard No: GB/T 42149-2022
Document status: VALID
Title in English: Railway application—Fixed installations—Technical specification for current protection of medium voltage power supply system based on digital communication
Title in Chinese: 轨道交通 地面装置 基于数字通信的中压供电系统电流保护技术规范
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2022-12-30
Implemented on: 2023-07-01
ICS Classification: 29.280-Electric traction equipment
Chinese Classification: S81-Traction substation
Professional Classification: GB-National Standard
Related Keywords: protection objects communication
relay protection device configuration relay protection devices
medium voltage power supply system
digital communication
digital communication introduction
Related Topics: medium voltage
Rail transit equipment protective grounding wire
Rail transit power supply system Europe

《GB/T 42149-2022轨道交通 地面装置 基于数字通信的中压供电系统电流保护技术规范》由TC278(全国轨道交通电气设备与系统标准化技术委员会)归口,TC278SC3(全国轨道交通电气设备与系统标准化技术委员会牵引供电分会)执行,主管部门为国家铁路局。


Introduction

1. Background and significance of standard formulation

With the rapid development of rail transit systems, the safety and reliability of medium-voltage power supply systems have become key issues. This standard aims to unify the technical requirements for current protection based on digital communication, ensure the interoperability of equipment from various manufacturers, and improve the stability of system operation.

2. Comparison of standard frameworks

Standard dimensions Old version requirements New version requirements Technological innovation
Protection scope Only covers some key equipment Fully covers ring network cables, busbars, feeders, etc. Expanded the scope of protection objects
Communication protocol No clear digital communication requirements Mandatory use of GOOSE network Introduction of digital communication technology
Redundancy configuration No clear redundancy requirements Requires dual redundant configuration Improve system reliability

3. Interpretation of core technical requirements

3.1 Relay protection device configuration

Relay protection devices based on digital communication must meet the following requirements:

  • Support GOOSE network transmission, with at least 2 interfaces, and optical fiber interfaces.
  • Equipped with an independent monitoring network interface to ensure the security of information transmission.
  • The protection function should be used in conjunction with overcurrent, zero-sequence current protection and other functions.

4. Implementation suggestions

In actual applications, it is recommended that:

  1. Select relay protection devices and network equipment in strict accordance with standard requirements.
  2. Establish a complete test verification mechanism to ensure that the equipment performance meets the requirements.
  3. Optimize the GOOSE network architecture to ensure that the communication delay is within 5ms.
  4. Perform regular system maintenance to ensure the accuracy and effectiveness of the protection configuration.

Sample only — not a preview of GB/T 42149-2022
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend

  • GB/T 36287.1-2025 in English

    GB/T 36287.1-2025 in English

    Railway applications—Fixed installations—Energy utilization for DC traction power supply—Part 1:Energy storage system

    2025-01-24
  • GB/T 25890.1-2026 in English

    GB/T 25890.1-2026 in English

    Railway applications—Fixed installations—DC switchgear—Part 1:General

    2026-01-28