GB/T 50361-2018 in English
VALIDTechnical standard for infills or partitions with timber framework
- Issued on:2018-07-10
- Implemented on:2018-12-01
- File Format:PDF
- Delivery:Via email within 5 business days
$612.00
| Standard No: | GB/T 50361-2018 |
| Document status: | VALID |
| Title in English: | Technical standard for infills or partitions with timber framework |
| Title in Chinese: | 木骨架组合墙体技术标准 |
| Language: | English |
| File Format: | Electronic (PDF) |
| Delivery: | Via email within 5 business days |
| Issued on: | 2018-07-10 |
| Implemented on: | 2018-12-01 |
| Superseding: |
GB/T 50361-2005 Technical code for partitions with timber framework
|
| Professional Classification: | GB-National Standard |
| Related Keywords: | innovation points technical indicators
technical standard timber framework introduction core technology sound insulation wall rock wool +10mm gypsum |
| Related Topics: | skeleton
bone wall Skeleton 38 Skeleton 41 wall Ketone skeleton body technology Binaphthyl skeleton GBT50361 GB/T 50361-2005 GB/T 50361-2018 bone glue technology technical standard font standard group analysis techniques |
Introduction
Core Technology and Innovation Points
| Technical Indicators | 2005 Edition | 20XX Revised Edition |
|---|---|---|
| Fireproof Material Performance | Only basic requirements are specified | Clear A-grade material standards (GB 8624) |
| Wall Column Spacing | 405/610mm | Newly added 450mm to adapt to 900mm panels |
| Seismic Design | Unspecified calculation formula | Newly added formulas (5.1.3)-(5.1.5) |
Key parameters of material performance
Comparison of sound insulation of gypsum board
| Thickness (mm) | Surface density (kg/m²) | 125Hz | 500Hz | 2000Hz |
|---|---|---|---|---|
| 9.5 | 9.5 | 11dB | 22dB | 27dB |
| 15.0 | 15.0 | 16dB | 28dB | 32dB |
Rock wool filling density requirements: household wall ≥28kg/m³, exterior wall ≥40kg/m³
Typical structural nodes
- Right-angle connection nodes: Use L50×50×4 angle steel for protection, screw spacing ≤750mm
- Electrical box installation: The sound insulation wall needs to be filled with Rock wool +10mm gypsum sealing layer on both sides
- Suspension system: Loads above 300N require φ6mm self-tapping screws, with a penetration depth of ≥30mm
Implementation suggestions
Special measures for severe cold regions
- Add vapor barrier (≥0.2mm plastic film)
- Use double-row wooden frame + double-layer paper-faced gypsum board
- The air layer is set on the low-temperature side
Red line indicators for quality acceptance
- Flatness deviation ≤3mm/2m
- Vertical deviation ≤3mm/2m
- Continuous fullness of fireproof sealant 100%

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 6494-2017 in English
Measurement method for electrical characteristics of aerospace solar cells
2017-11-01 -

GB/T 18376.3-2015 in English
Grades of cemented carbide—Part 3: Grades of cemented carbide for wear parts
2015-12-10 -

GB/T 10095.1-2022 in English
Cylindrical gears—ISO system of flank tolerance classification—Part 1:Definitions and allowable values of deviations relevant to flanks of gear teeth
2022-10-12 -

GB 12026-1989 in English
Biaxally oriented polypropylene film for hert-seal
1989-12-27 -

GB/T 33174-2022 in English
Asset management—Management systems—Guidelines for the application of GB/T 33173
2022-12-30 -

GB/T 12705.1-2024 in English
Textile—Methods of testing the down-proof property —Part 1: Rubbing test
2024-03-15 -

GB/T 13539.5-2020 in English
Low-voltage fuses—Part 5: Guidance for the application of low-voltage fuses
2020-11-19 -

GB/T 34877.4-2024 in English
Industrial fans—Determination of fan sound power levels under standardized laboratory conditions—Part 4:Sound intensity method
2024-05-28 -

GB/T 40259-2021 in English
General specification for supporting quality of longwall face
2021-05-21 -

GB/T 36652-2018 in English
Specification for TFT liquid crystal mixtures
2018-09-17