Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
innovation points technical indicators technical standard timber framework introduction core technology sound insulation wall rock wool +10mm gypsum application glycine content pole path design steel plates/angle
GB/T 50361-2018 in English

GB/T 50361-2018 in English

VALID

Technical standard for infills or partitions with timber framework

  • Issued on:2018-07-10
  • Implemented on:2018-12-01
  • File Format:PDF
  • Delivery:Via email within 5 business days
Price(USD): $630.00
$612.00
Standard No: GB/T 50361-2018
Document status: VALID
Title in English: Technical standard for infills or partitions with timber framework
Title in Chinese: 木骨架组合墙体技术标准
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 5 business days
Issued on: 2018-07-10
Implemented on: 2018-12-01
Superseding: GB/T 50361-2005 Technical code for partitions with timber framework
Professional Classification: GB-National Standard
Related Keywords: innovation points technical indicators
technical standard
timber framework introduction core technology
sound insulation wall
rock wool +10mm gypsum
Related Topics: skeleton
bone
wall
Skeleton 38 Skeleton 41
wall
Ketone skeleton
body technology
Binaphthyl skeleton
GBT50361
GB/T 50361-2005
GB/T 50361-2018
bone glue technology
technical standard font
standard group analysis techniques


Introduction

Core Technology and Innovation Points

Technical Indicators 2005 Edition 20XX Revised Edition
Fireproof Material Performance Only basic requirements are specified Clear A-grade material standards (GB 8624)
Wall Column Spacing 405/610mm Newly added 450mm to adapt to 900mm panels
Seismic Design Unspecified calculation formula Newly added formulas (5.1.3)-(5.1.5)

Key parameters of material performance

Comparison of sound insulation of gypsum board

Thickness (mm) Surface density (kg/m²) 125Hz 500Hz 2000Hz
9.5 9.5 11dB 22dB 27dB
15.0 15.0 16dB 28dB 32dB

Rock wool filling density requirements: household wall ≥28kg/m³, exterior wall ≥40kg/m³


Typical structural nodes

  1. Right-angle connection nodes: Use L50×50×4 angle steel for protection, screw spacing ≤750mm
  2. Electrical box installation: The sound insulation wall needs to be filled with Rock wool +10mm gypsum sealing layer on both sides
  3. Suspension system: Loads above 300N require φ6mm self-tapping screws, with a penetration depth of ≥30mm

Implementation suggestions

Special measures for severe cold regions

  • Add vapor barrier (≥0.2mm plastic film)
  • Use double-row wooden frame + double-layer paper-faced gypsum board
  • The air layer is set on the low-temperature side

Red line indicators for quality acceptance

  • Flatness deviation ≤3mm/2m
  • Vertical deviation ≤3mm/2m
  • Continuous fullness of fireproof sealant 100%

Sample only — not a preview of GB/T 50361-2018