GB/T 5195.7-2016 in English
VALIDFluorspar―Determination of zinc content―Flame atomic absorption spectrophotometric method
- Issued on:2016-12-13
- Implemented on:2017-09-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$156.00
《GB/T 5195.7-2016萤石 锌含量的测定 原子吸收光谱法》由TC183(全国钢标准化技术委员会)归口,TC183SC17(全国钢标准化技术委员会冶金非金属矿产品分会)执行,主管部门为中国钢铁工业协会。
Introduction
GB/T5195.7-2016 Standard Overview
This part of the standard specifies the method for determining the zinc content in fluorite using atomic absorption spectrometry, which is applicable to the detection of zinc content in the range of 0.020% to 1.0% by mass. This method decomposes the sample by mixed acid solution and measures the absorbance of zinc at a wavelength of 213.9 nm using an air-acetylene flame.
Comparison of Standard Frameworks
| Project | GB/T5195.7-2016 | ISO Reference Standard | American Society for Testing and Materials (ASTM) |
|---|---|---|---|
| Scope of Application | Determination of Zinc Content in Fluorite | General Metal Analysis | Metal Detection in Ores and Rocks |
| Principle of Method | Atomic Absorption Spectrometry | ICP-OES | XRF |
| Detection Limit | 0.020% | 0.01% | 0.05% |
Technical Points Interpretation
Reagents and Instrument Requirements
The standard clearly requires the use of analytically pure reagents and puts forward strict requirements on the quality level of water (secondary water and above). The main reagents include hydrochloric acid, sulfuric acid, hydrofluoric acid and perchloric acid, which must be prepared in strict proportion. In terms of instruments, the atomic absorption spectrometer must have an air-acetylene burner and be equipped with a zinc hollow cathode lamp.
Sample Preparation and Analysis Steps
The sample must be dried and finely ground to a particle size of less than 63μm before analysis. The sample is weighed in an amount of 0.20g±0.1mg. After decomposition by the mixed acid solution, it is transferred to a volumetric flask to make up the volume. The calibration curve uses a six-point correction method to ensure that the linear relationship meets the standard requirements.
Implementation Suggestions
- Equipment Calibration: Calibrate the atomic absorption spectrometer regularly to ensure that the wavelength accuracy and sensitivity meet the requirements.
- Reagent Management: Establish a reagent management system to ensure the accuracy of the concentration of reagents such as hydrochloric acid and sulfuric acid.
- Quality Control: Add blank tests and repeated measurements during the analysis to ensure the reliability and accuracy of the data.
- Staff Training: Conduct regular training for operators, focusing on strengthening the ability to prepare standard curves and analyze abnormal data.
Precision and Result Processing
According to the standard requirements, the precision of the determination of zinc content is determined by 7 laboratories jointly measuring 5 horizontal samples. When calculating the repeatability limit and reproducibility limit, it is necessary to note that the average of the two measured values is used as the basis, and the prerequisite of not more than 5% is met.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 3286.2-2025 in English
Methods for chemical analysis of limestone and dolomite—Part 2: Determination of silicon and aluminium content
2025-08-29 -

GB/T 5195.1-2017 in English
Fluorspar--Determination of calcium fluoride content--EDTA titration method and distillation-potentiometric titration method
2017-09-07 -

GB/T 31311-2014 in English
Metallurgical-grade fluorspar―Determination of lead content―Solvent extraction atomic absorption spectrometric method
2014-12-05 -

GB/T 32549-2016 in English
Fluorspar―Experimental methods for evaluation of quality variation
2016-02-24