Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
air speed introduction standard overview metrology laboratory professional technical standard technical requirements first-class standard requirements motor vehicle driver examination systems electric shock scopethis part containerized traffic
QX/T 219-2013 in English

QX/T 219-2013 in English

VALID

Technical requirements for metrology laboratory of air speed

  • Issued on:2013-12-22
  • Implemented on:2014-05-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $120.00
$117.00
Standard No: QX/T 219-2013
Document status: VALID
Title in English: Technical requirements for metrology laboratory of air speed
Title in Chinese: 空气流速计量实验室技术要求
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2013-12-22
Implemented on: 2014-05-01
Professional Classification: QX-Meteorology
Related Keywords: air speed introduction standard overview
metrology laboratory
professional technical standard
technical requirements
first-class standard requirements
Related Topics: Experimental Technology
laboratory technology
Frontier Technology Lab
laboratory flow meter
Gas Flow Meter Technology
Laboratory Technical Requirements
Gas flowmeter technical requirements
Gas Flow Meter Flow Rate
Laboratory technical indicators
laboratory flow meter
zero air flow
Experimental Technology
flow rate of the flowmeter
laboratory gas
Laboratory Gas Flow Meter
air mass flow rate
laboratory air quality
Technology Application Laboratory
air mass flow rate
laboratory air quality
laboratory gas path
laboratory gas path
Laboratory Technical Requirements
Mass flow meter technical requirements
Laboratory Technical Requirements
Mass flow meter technical requirements
fluid lab
Laboratory Gas Flow Meter
Mass flow meter technical requirements
laboratory nitrogen gas
laboratory technology
Surface Technology Laboratory
flow rate meter
technical gas chamber
flowmeter laboratory
air velocity
Laboratory Reagent Requirements
Laboratory Gas Flow Meter
Number of laboratories
laboratory air
Flowmeter experiment
laboratory calorimeter
p4 laboratory process
flowmeter laboratory
hot air laboratory
Metrology laboratory
p4 laboratory process
mobile phase laboratory
Laboratory gas velocity measurement
Rapid Laboratory Design Statistical Analysis
laboratory carrier gas
Rapid Lab Tech Software
food laboratory technical requirements
Laboratory Technical Requirements
Metrology Standards Laboratory
Laboratory Technology Software
p4 laboratory technology
Number of laboratories
Metrology laboratory
laboratory air tank
mobile laboratory
QX
laboratory nitrogen
calorimeter experiment
laboratory calorimeter
laboratory air equipment
Technical Requirements for Air Velocity Measurement Laboratory
Experimental Technical Requirements
The number of laboratories in each province
Air Velocity Measuring Instruments
air velocity
Laboratory Gas Acceptance
laboratory air method
Laboratory Specifications
laboratory technical level
laboratory micropump
laboratory micropump
Laboratory Reagent Requirements
Sheath gas flow rate 40
Vacuum Laboratory Design
Nitrogen tank laboratory
Rapid Fire Test Laboratory
plume lab
Quantitative experiment
qx/t 79.2-2013
laboratory mobile phase
plume lab
laboratory nitrogen machine
laboratory deuterium
Large-scale experimental laboratory requirements
Sheath gas flow
flow rate meter
laboratory flowmeter
laboratory mass flow
oxygen laboratory
The lab has a copy in the air
Laboratory short-range technology
How to design a flow laboratory
Special Electrical Technology Laboratory
oxygen laboratory
Laboratory Measurement Technology
Nitrogen flow meter and argon flow meter
Gas phase flow rate
TaqMan OpenArray Experimental Technology
ICP laboratories need to install air conditioning
T/CMA NY050-2020 Technical requirements for industrial steam flow measurement
Flow velocity measurement experiment report
Air conditioning quality requirements technology
Jet cavitation experiment
flow lab
Requirements for special flowmeters for offshore oil
Bashi flow meter technology
laboratory air compressor
Laboratory air pressure power design standards
First-class laboratory
Flow flow technology
airtight laboratory
Laboratory exhaust gas disposal specification requirements
Laboratory hole opener technology
Laboratory cylinder room design requirements standards
Hydrogen Generator Laboratory Design


Introduction

Standard Overview and Technical Background

QX/T 219-2013 is a professional technical standard formulated by my country's meteorological industry for air velocity measurement laboratories, which was issued in December 2013 and officially implemented in May 2014. This standard fills the gap in the construction specifications of meteorological wind tunnel laboratories and provides unified laboratory technical requirements for the measurement and calibration of meteorological instruments such as wind velocity sensors.


Analysis of core technical requirements

1. Infrastructure specifications

Project Recirculation wind tunnel Direct current wind tunnel
Spatial spacing Tunnel distance to wall ≥1m Air outlet distance to wall ≥2 times of air inlet diameter
Functional isolation Laboratories are prohibited from being used for other purposes. Direct current wind tunnels require independent control rooms
Power supply system Dual power supply isolation (220V/380V), UPS capacity ≥ 2 times the load

2. Environmental control indicators

  • Temperature and humidity: 15-30℃, ≤85%RH
  • Noise: <85dB at 1m from the test section (in line with GB 3096-2008)
  • Illumination: 500lx (refer to GB 50034-2004)

Metrology standard classification system

Grade Wind speed range (m/s) Uncertainty (1-12m/s) Uncertainty (>12m/s)
First-class standard 0.2-80 0.08m/s(k=2) 0.62%(k=2)
Second-class standard 0.2-30 0.15m/s(k=2) 1.24%(k=2)

Application Case: Wind Tunnel Laboratory Reconstruction

A provincial meteorological metrology station referred to this standard to convert the original The class=instrument>DC wind tunnel laboratory was upgraded:

  1. An independent control room was added to achieve human-machine separation
  2. A dual-channel UPS system was installed to ensure the power supply of the standard instrument
  3. A foam fire extinguishing system was used to replace the traditional dry powder fire extinguishing

After the transformation, the laboratory passed the CNAS certification, and the expanded uncertainty reached the first-class standard requirements.


Suggestions for the implementation of the standard

1. Matters needing attention during the construction phase

  • The wind tunnel selection should be combined with QX/T 8-2007 "Meteorological Low-speed Wind Tunnel Performance Test Specification"
  • The power supply system must comply with the voltage deviation requirements of GB/T 12325-2008
  • Grounding resistance <4Ω (refer to GB 50169-2006)

2. Key points for daily operation and maintenance

  • Regularly calibrate environmental measuring instruments (temperature meter tolerance ±0.35℃, humidity meter ±5%RH)
  • Test the noise level every quarter (GB 22337-2008)
  • Establish a power supply system inspection system