Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
cone calorimeter method introduction technical background rate-test method key equipment cone calorimeter testing method radiation cone linear motor traction system projects prescribed forms hydraulic impact hammer introductionthis standard
SN/T 5240-2020 in English

SN/T 5240-2020 in English

VALID

Import and export textiles-Heat release rate-Test method of cone calorimeter method

  • Issued on:2020-08-27
  • Implemented on:2021-03-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $250.00
$243.00
Standard No: SN/T 5240-2020
Document status: VALID
Title in English: Import and export textiles-Heat release rate-Test method of cone calorimeter method
Title in Chinese: 进出口纺织品 热释放速率测定 锥形量热仪法
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2020-08-27
Implemented on: 2021-03-01
Professional Classification: SN-Import&Export Inspection
Related Keywords: cone calorimeter method introduction technical background
rate-test method
key equipment cone calorimeter
testing method
radiation cone
Related Topics: Calorimeter
Thermal conductivity meter
Cone Calorimeter
Quality heat meter
Large Cone Calorimeter
Variety Thermometer
Taper amount
Micro Cone Calorimeter
Thermal conductivity meter
Cone Calorimeter Large
Cone calorimeter
Thermometer Products
cone calorimetry
calorimetry
exothermic
instrument import
micro cone calorimetry
Column derivatizer import and export
Cone calorimeter sample preparation
Cone Calorimeter Test
Cone Calorimeter + Test
Cone Calorimeter
Cone Calorimeter
Based on cone calorimeter
accelerated calorimetry
Thermometer
For calorimeters
Cone calorimeter used
Determination method of heat sealer
Calorimetry
Instrument import and export
Instrument import and export
Rapid Thermal Conductivity Meter
accelerated calorimetry
Cone gauge
Imported centering instrument
For calorimeters
total heat release
Calorific value
How the heat release rate is measured
Quantitative calorimeter
heat release rate
rate instrument
exothermic peak heat
cone method
rate instrument
Yield rate Yield rate
Imported brand
Thermal speed working instrument
Heat release rate
Calorimeter Calorimeter
Multi-purpose calorimeter
heat release
accelerated adiabatic calorimeter arc
Imported pure water meter
What is the general heat capacity of a calorimeter?
SDACM4000 calorimeter
Calorimeter Parr6400
Testing of thermal transmittance, thermal reflectivity and thermal absorptivity of textiles
Cone penetration import
Export textiles
Textile export inspection related
Cone calorimeter test method steps
China Customs Textile Import Quality
Calorimeter identification
Drug release rate measurement method


Introduction

Technical background and evolution of the standard

As an important technical specification issued by the General Administration of Customs in 2020, this standard fills the gap in the testing method for quantitative evaluation of the flammability of textiles. Its technical framework is inherited from GB/T 16172-2007 building materials test method, but three major innovations have been made for the characteristics of textiles:

  • Sample treatment: Add aluminum foil wrapping process to control edge burning effect
  • Radiation parameters: Set three levels of radiation illumination of 25/35/50 kW/m² to correspond to different fire scales
  • Termination conditions: Clarify the termination judgment criteria for 4 types of tests

Analysis of core detection principles

Heat release rate calculation formula based on the oxygen consumption principle:

qA(t) = 1.10×13.1×10³×C×(Δp/√Te)×(XO20-XO2)/(1.105-1.5XO2)/0.0088

Key parameters in the formula:

ParameterPhysical meaningUnitAcquisition method
CInstrument calibration constantm1/2·g1/2·K1/2Equipment calibration value
ΔpOrifice pressure differencePaReal-time monitoring
XO20Initial oxygen concentrationmol/mol60-second average value

Technical requirements for key equipment

Cone calorimeter as the core equipment must meet the following requirements:

  • Radiation uniformity: Deviation within 50×50mm range ≤±2%
  • Oxygen analyzer accuracy: 30-minute drift <50ppm
  • Weighing system: Response time <4s, range ≥500g

Appendix A specifies the equipment structure requirements in detail, including the dimensional tolerances of key components such as the radiation cone (Figure A.1) and the positioning frame (Figure A.3).


Standardized operating procedures

  1. Sample preparation: Three layers of 100×100mm samples stacked, wrapped in aluminum foil (3mm beyond the upper surface)
  2. Environmental control: Temperature 15-30℃, humidity 20-80%
  3. Radiation calibration: Cone distance from sample (25±1)mm
  4. Ignition procedure: Water-cooled/non-water-cooled shielding layer difference operation
  5. Data acquisition: Oxygen concentration is recorded every 5 seconds until the termination condition is triggered

Implementation suggestions and risk control

Case: In the test of a flame-retardant curtain for an export, flash fire occurred under 50kW/m² radiation. Valid data was obtained by adjusting the sample positioning method (horizontal→vertical).

Special situation handling:

  • Short-term combustion: duration 1-10s needs to be recorded separately
  • Toxic gas: forced exhaust system must be equipped
  • Abnormal data: check the saturation status of the CO₂ filter