Background of Standard Revision and Technological Evolution
SY/T 5660-2020 is a comprehensive upgrade of the 1995 version of the standard. The main technological changes are reflected in:
| Dimensions | 1995 version | 2020 version | Technical differences |
|---|---|---|---|
| Standard name | Drilling fluid coating agent PAC141, etc. | Unified as polyacrylamide | Expanded scope of application |
| Technical indicators | 7 items | 13 items | 6 items such as intrinsic viscosity were added |
| Test methods | Chapter 4 | Section 13 | Improve the high temperature performance test process |
| Environmental protection requirements | None | Independent chapter | New safety and environmental protection clauses |
Analysis of core performance indicators
Key parameter requirements
The standard stipulates that the intrinsic viscosity tested by the Ubbelohde viscometer must be ≥6.0 100mL/g, the apparent viscosity of 1% aqueous solution must be ≥30.0mPa·s, and the linear expansion reduction rate of the core must be>50%. After hot rolling at 120℃ for 16h, salt-resistant products must still maintain the following:
- Apparent viscosity>10.0mPa·s
- Low-temperature and low-pressure filtration loss reduction rate>60%
Instrument and equipment specifications
The standard clearly requires the use of professional equipment such as Fann35 rotational viscometer and NP-01 shale expansion tester, among which:
- The high-speed agitator must meet the speed of 11000r/min±300r/min
- The capillary diameter of the Ubbelohde viscometer is limited to 0.55-0.57mm
- The temperature control accuracy of the constant temperature water bath is ±0.2℃
Implementation suggestions and precautions
Inspection link
Sampling shall be carried out in accordance with GB/T 6679, and the total amount ≥1kg shall be divided into 3 portions. Special attention:
- The intrinsic viscosity test needs to be controlled at a constant temperature of 30℃
- The flocculation time measurement needs to use a 250mL stoppered measuring cylinder with a scale
- Before the high temperature performance test, nitrogen must be passed at 0.7MPa for 30s
Safety protection
The standard adds Chapter 7 with clear requirements:
- Operators need to wear protective glasses
- When materials are scattered, they must be immediately adsorbed with inert materials
- Waste packaging should be uniformly recycled

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

SY 5502-1992 in English
Standard labor conversion method for seismic exploration
1992-11-03 -

SY/T 5429-1991 in English
Small diameter flow moisture tester
1992-01-15 -

SY 5041-1992 in English
elevator
1992-09-17 -

SY/T 6537-2016 in English
Analysis methods of gas and solution for natural gas treating plant
2016-12-05 -

SY/T 5439-2003 in English
Pneumatic cement-discharging tanker
2003-03-18 -

SY/T 6145-2019 in English
Near surface seismic instrument for petroleum exploration
2019-11-04 -

SY/T 0081-2023 in English
Specification for design of crude oil thermo-chemical settling dehydration
2023-05-26 -

SY 6456-2000 in English
Safety production rules for gather station of sour natural gas
2000-03-31 -

SY/T 6179-1996 in English
Calibration Regulations for Compensated Neutron Logging Tool
1996-04-21 -

SY/T 6182-1996 in English
Production Profile Logging Tool Calibration Procedure Fluid Density Logging Tool
1996-04-21