Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
safety control systems system automatic system % system integrity rate ∑ gas pipeline introduction analysis natural gas pipeline stations hazardous chemicals vehicle transportation aluminum bus-bar welding project iso standards mandatory requirements
SY/T 6069-2020 in English

SY/T 6069-2020 in English

VALID

Specification of running technology for the instrument and automatic system of the oil and gas pipeline

  • Issued on:2020-10-23
  • Implemented on:2021-02-01
  • File Format:PDF
  • Delivery:Via email within 5 business days
Price(USD): $480.00
$466.00


Introduction

Analysis of Standard Technology Evolution

Version Main Changes Technological Advancement
2011 Edition Establishment of Basic Framework Conventional Automation Control
2020 Edition Addition of 12 new technical requirements such as flammable/toxic gas detection, fire control, and network security Intelligence + Safety Integrity Level (SIL) certification

Technical Requirements for Core Instruments

Temperature Measurement Instruments

  • ≤300℃, use Pt100 B-grade thermal resistor
  • >300℃, use K/E-type armored thermocouple
  • Switch setting error ≤1%

Pressure transmitter

  • Intelligent accuracy ≥0.1 level
  • Capillary pressure measurement is preferred for crude oil pipelines

Key points for the implementation of safety control systems

System type Key indicators Maintenance cycle
Combustible gas detection Response time ≤ 60s (diffusion type) Quarterly calibration
Safety Instrument (SIS) SIL certified controller Annual functional test

Typical case: Natural gas pipeline stations need to be equipped with dual redundant UPS power supplies, with a backup time ≥ 1.5 hours


SCADA system operation and maintenance specifications

  • Screen refresh time < 2 seconds
  • Dual-machine hot standby switching without disturbance
  • Strictly implement three-level permission management (browsing/operation/system)
  • Prohibit physical connection to the office network

Management indicator system

Indicators Calculation formula Meeting standard value
Equipment utilization rate ∑(single unit in use days)/(total number of units × number of days in a month) ≥98%
System integrity rate ∑(single unit in use days)/(total number of units × number of days in a month) ≥98%

Sample only — not a preview of SY/T 6069-2020