Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
hydrocarbon dew point- cooled mirror hydrocarbon dew point high hydrocarbon dew point samples automatic method introduction interpretation ama-hcp3000 dew point meter carbon material determination fluorine content ion virtual terminal introductionthis standard
SY/T 7484-2020 in English

SY/T 7484-2020 in English

VALID

Natural gas-Determination of the hydrocarbon dew point- Cooled mirror automatic method

  • Issued on:2020-10-23
  • Implemented on:2021-02-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $160.00
$156.00
Standard No: SY/T 7484-2020
Document status: VALID
Title in English: Natural gas-Determination of the hydrocarbon dew point- Cooled mirror automatic method
Title in Chinese: 天然气 烃露点的测定 冷却镜面自动检测法
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2020-10-23
Implemented on: 2021-02-01
Professional Classification: SY-Oil & Gas
Related Keywords: hydrocarbon dew point- cooled mirror
hydrocarbon dew point
high hydrocarbon dew point samples
automatic method introduction interpretation
ama-hcp3000 dew point meter
Related Topics: mirror
hydrocarbon
dew point
Hydrocarbon
Features of regular testing
Hydrocarbon detector
Hydrocarbon detection method
Hydrocarbon dew point
natural gas hydrocarbon
natural gas dew point
dew point of natural gas
Dew point measurement
Dew point test
natural gas dew point
dew point pressure
automatic cooling
natural gas ignition
mirror dew point
mirror dew point
dew
Automatic microscope inspection
mirror dew point
natural detection
pressure dew point
Detection of Organic Hydrocarbons
dew point
Dew point measurement method
natural gas leak
Dew point meter Dew point meter
Petroleum hydrocarbons, automatic detection
Natural gas dew point meter
Dew point test
Hydrocarbon dew point
Natural gas hydrocarbon dew point
FId detector measures natural gas
Lens condensation test
Detection of compressed natural gas water dew point
Cooling water testing
natural gas leak
What are the calibration methods for measuring dew point?
Balance inspection
Detection of heavy metal components in natural gas
Gas dew point detection method
Natural gas component detection
sy/t 7494-2020
Methods for detecting line dew point
sy/t 7466-2020
sy/t 7468-2020


Introduction

Interpretation of the core content of the standard

This standard specifies the method of measuring the hydrocarbon dew point of pipeline natural gas using a cooling mirror automatic detector, with a measurement accuracy of ±0.5℃. It is applicable to single-phase natural gas, but not to gas containing liquid hydrocarbons.


Technical principles and instrument requirements

ComponentsTechnical requirementsAccuracy indicators
Mirror temperature moduleAutomatic cooling control±0.5℃
Pressure measurement moduleExplosion-proof designGrade 1.0 accuracy
Sample processing unitPressure stabilization and filtrationFlow rate 1-3L/min

Key points of the operation process

  1. Sampling requirements: The pipeline temperature must be at least 3°C higher than the estimated hydrocarbon dew point, and the low temperature environment must be heated and kept warm
  2. Flow control: Maintain a constant flow of 1-3L/min during formal measurement
  3. Repeatability verification: The difference between two consecutive measurements must be ≤2.0°C to be valid

Application case: A West-East Gas Transmission Station uses an AMA-HCP3000 dew point meter. The hydrocarbon dew point is measured to be -15.2°C at a pressure of 5.0MPa. The maximum deviation of three repeated measurements is 1.3°C, which meets the standard requirements.


Background of Standard Evolution

Compared with the visual inspection method of GB/T 27895-2011, this standard introduces automated detection technology, reducing the manual judgment error from ±3℃ to ±2℃, and increasing explosion-proof safety requirements to adapt to the actual working conditions of the station.


Implementation Suggestions

  • Regularly use propane standard gas (-42.1℃@101.325kPa) for instrument calibration
  • For high hydrocarbon dew point samples (>0℃), the purge flow rate needs to be increased to 5L/min
  • Establish a mirror contamination assessment system, and clean the mirror when the repeatability is >1.5℃