YY/T 1504-2016 in English
VALIDImplants for surgery―Test method for determining the axial pullout strength of metallic bone screws
- Issued on:2016-07-29
- Implemented on:2017-06-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$97.00
| Standard No: | YY/T 1504-2016 |
| Document status: | VALID |
| Title in English: | Implants for surgery―Test method for determining the axial pullout strength of metallic bone screws |
| Title in Chinese: | 外科植入物金属接骨螺钉轴向拔出力试验方法 |
| Language: | English |
| File Format: | Electronic (PDF) |
| Delivery: | Via email within 1~3 business days |
| Issued on: | 2016-07-29 |
| Implemented on: | 2017-06-01 |
| ICS Classification: | 11.040.40-Implants for surgery, prosthetics and orthotics |
| Chinese Classification: | C35-Orthopedic devices |
| Professional Classification: | YY-Pharmaceutics |
| Related Keywords: | metal bone screws
test method axial pullout strength metallic bone axial force |
| Related Topics: | bone screw
bone screw yy/t 1504 ny/t 1504 as1504 The pull-out force gauge complies with Measurement methods of heavy metals in plants Standard method for heavy metals in plants Plant heavy metal detection methods Seal strip pull-out force test method Plant exosome verification method Metal orthopedic implants Dental nail pull-out force test method literature |
本标准规定了测量金属接骨螺钉从规定材料中拔出或失效所需的轴向力的试验方法。本标准适用于金属接骨螺钉,本标准不适用于某些特殊用途的螺钉。
Scope
This standard specifies a test method for measuring the axial force required to pull out or fail metal bone screws (hereinafter referred to as "screws") from specified materials. This standard is only used to confirm the consistency of the product being tested or to compare the force values of different products. It is not used to predict the force value of screws pulled out from human bones. This standard may not apply to screws for some special purposes. It is recommended that the applicability of this standard be considered from the perspective of the specific material of the screw and its intended use.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

YY/T 1982-2025 in English
Test Method for Morphological Characteristics of Porous Structures in Surgical Implants
2025-06-18 -

YY/T 1926.2-2024 in English
Preclinical mechanical evaluation and special requirements for spinal implants Part 2: Intervertebral fusion cages
2024-09-29 -

YY/T 1935-2024 in English
Safety requirements and test methods for implantable cardiac pacemakers and cardioverter-defibrillators in a magnetic resonance environment
2024-07-08 -

YY/T 1934-2025 in English
Human factors design requirements and evaluation methods for orthopedic implants and surgical instruments
2025-02-26 -

YY/T 0663.2-2024 in English
Cardiovascular implantable devices Intravascular devices Part 2: Vascular stents
2024-02-07