Withstand voltage insulation test
Withstand voltage insulation test, Total:308 items.
The international standard classification for "Withstand voltage insulation test" includes: Electricity. Magnetism. Electrical and magnetic measurements , Industrial automation systems in general , Insulating gases , Transformers. Reactors , Motors , Insulating materials in general , Electrical accessories in general , Power stations in general , Aerospace electric equipment and systems .
The Chinese standard classification for "Withstand voltage insulation test" includes: Technical management , Other electronic instrument and equipment , Industrial automation and control device in general , Basic standards and general methods for adhesives , Transformer , Electrical insulating material and its products , Special machine , Electric rotating machinery in general , Asynchronous machine , Electric power testing technique , Basic standards and general methods , Signal equipment , Electrical system and equipment .
Professional Standard - Electron
- SJ/T 11385-2008 General specification of insulation resistance tester
- SJ 2215.14-1982 Method of measurement for input-to-output isolation voltage of semiconductor photocouplers
- SJ 2215.13-1982 Method of measurement for input-to-output isolation resistance of semiconductor photocouplers
Anhui Provincial Standard of the People's Republic of China
- DB34/T 3571-2019 Electrical test method for insulating layer of large superconducting magnet
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
- GB/T 14517-1993 Test method for dielectric strength of insulating adhesive tape at power frequency
- GB 1094.3-1985 Power transformers-Part 3: Insulation levels and dielectric tests
- GB/T 22718-2008 Thermal evaluation methods of insulation systems for high-voltage electrical machines
- GB/T 1411-2002/IEC 61621:1997 Dry,solid insulating materials--Resistance test to high-voltage,low-current arc discharges
- GB/T 1411-2002/IEC 61621-1997 Dry,solid insulating materials--Resistance test to high-voltage,low-current arc discharges
- GB 1094.3-2003 Power transformers?Part 3:Insulation levels,dielectric tests and external clearances in air
- GB/T 5134-1985 Test methods of laminated rods used for electrical insulation
- GB/T 10237-1988 Power transformers-Insulation levels and dielectric tests external clearances in air
- GB/T 1411-2002 Dry, solid insulating materials-Resistance test to high-voltage, low-current arc discharges
- GB/T 13501-1992 Electric motors for hermetic refrigeration compressors-Test methods of insulation resistance to freon
- GB/T 15479-1995 Technical requirements and test methods of insulation resistance and insulating strength for use in industrial process measurement and control instruments
- GB/T 1094.3-2017 Power transformers—Part 3:Insulation levels,dielectric tests and external clearances in air
- GB/T 1739-1979 Method of test for transformer oil resistance of electrical insulating varnish films
Professional Standard - Machinery
- JB/T 7082-1993 Dielectric Withstand Testing Instruments for Insulating Medium
- JB/T 7589-1994 Evaluation method for heat resistance of insulation structure of high voltage motor
- JB/T 6204-2002 Specifications for Withstanding Voltage Test Oil Stator Coil and
- JB/T 9588.2-1999 Test method for ceramic insulators of spark plug.Test method for voltage proof
- JB/T 7589-2007 Thermal evaluation methods of insulation systems for high-voltage electrical machines
- JB/T 7082-2013 Dielectric voltage-withstand tester
- JB/T 7616-1994 Steep current impulse resistance test for insulator of high-tension lines
Taiwan Provincial Standard of the People's Republic of China
- CNS 9808-1983 Method of Test for Control Gear Insulation
- CNS 14256-1998 Method of test for withstand voltage of personal protective equipment and insulation devices
- CNS 6040-1980 Method of Test for Electric Strength of Solid Insulating Materials
- CNS 3988-2000 Dielectric Properties of Control Device
- CNS 6788-1980 Strain Type Insulators
Professional Standard - Electricity
- DL/T 474.4-2006 Guide for insulation test on site AC voltage withstanding test
- DL/T 555-2004 Guide for withstand voltage and insulated test of gas-insulated metal-enclosure switchgear on site
- DL/T 555-1994 Guide for Withstand Voltage Test of Gas-Insulated Metal-Enclosure Electric Appliance on Site
- DL 474.4-1992 Guidelines for Implementation of On-Site Insulation Tests AC Withstand Voltage Test
- DL/T 1694.4-2017 Calibration specification for high voltage testing instruments. Part 4: Insulation oil voltage withstanding tester
- DL/T 474.4-2018 Guide for insulation test on site AC voltage withstanding test
Professional Standard - Automobile
- QC/T 433-1999 Test method for ceramic insulators of spark plugs - Test method for pressure resistance
Professional Standard - Railway
- TB/T 1448-1982 Insulation and Voltage Resistance for Communication Signal Products
机械工业部
- JB 6204-1992 Specifications for stator insulation withstand voltage test of large high-voltage AC motors
中华人民共和国国家质量监督检验检疫总局、中国国家标准化管理委员会
- GB/T 35856-2018 Methods of insulation resistance test and resistant high voltage test for aircraft electrical equipment
未注明发布机构
- IEEE Std 82-2002(R2009) IEEE Test Procedure for Impulse Voltage Tests on Insulated Conductors
- CAN/ULC-S129-15 STANDARD METHOD OF TEST FOR SMOULDER RESISTANCE OF INSULATION (BASKET METHOD)
国家铁路局
- TB/T 1448-2018 Isolation voltage of railway communication & signal product
Professional Standard - Aerospace
- QJ 2220.3-1992 Coating electrical insulation performance test method Measurement method of breakdown voltage, breakdown strength and withstand voltage under power frequency
Professional Standard - Chemical Industry
- HG/T 3857-2006 Method of test for transformer oil resistance of electrical insulating varnish films
中华人民共和国国家质量监督检验检疫总局
- GB/T 1094.3-2003 Power transformers--Part 3: Insulation levels,dielectric tests and external clearances in air
Group Standards of the People's Republic of China
- T/CSEE 0231-2021 Guidelines for on-site AC withstand voltage test of XLPE insulated power cables
Korean Agency for Technology and Standards (KATS)
- KS C 2127-1996 Testing method for proof-voltage testing of thin solid electrical insulating materials
- KS C 2105-2003 Testing methods for electric strengthof solid insulating materials
- KS C 2105-1982 Testing methods for electric strengthof solid insulating materials
- KS C 2127-1996(2021) Testing method for proof-voltage testing of thin solid electrical insulating materials
- KS C 2127-2021 Testing method for proof-voltage testing of thin solid electrical insulating materials
- KS R 9197-1996(2016) Test methods for insulation resistance and withstand voltage of railway rolling stock
- KS R 9197-2022 Test methods for insulation resistance and withstand voltage of railway rolling stock
- KS R 9197-1996 Test methods for insulation resistance and withstand voltage of railway rolling stock
- KS P 8010-2023 Testing method for withstand voltage of personal protective equipment and insulating devices
- KS R 9193-2022 Insulation resistance and withstand voltage testing methods of parts for railway signaling
- KS C IEC 60216-5-2014(2019) Electrical insulating materials — Thermal endurance properties — Part 5:Determination of relative thermal endurance index(RTE) of an insulating material
- KS C IEC 60437:2020 Radio interference test on high-voltage insulators
- KS R 9193-1996 Insulation resistance and withstand voltage testing methods of parts for railway signaling
- KS P 8010-1987 Testing method for withstand voltage of personal protective equipment and insulating devices
- KS P 8010-2007 Testing method for withstand voltage of personal protective equipment and insulating devices
- KS R 9193-1996(2016) Insulation resistance and withstand voltage testing methods of parts for railway signaling
- KS P 8010-2018 Testing method for withstand voltage of personal protective equipment and insulating devices
- KS C IEC 60216-2-2008(2018) Electrical insulating materials-Thermal endurance properties-Part 2:Determination of thermal endurance properties of electrical insulating materials-Choice of test criteria
- KS C 2130-1996(2021) Testing method for high-voltage, low-current, dry arc resistance of solid electrical insulation
- KS C IEC 60216-2-2023 Electrical insulating materials-Thermal endurance properties-Part 2:Determination of thermal endurance properties of electrical insulating materials-Choice of test criteria
- KS C IEC 61621:2014 Dry, solid insulating materials — Resistance test to high-voltage, low-current arc discharges
- KS C 3827-2003 Normal type and anti-pollution type suspension insulators
- KS C IEC 60216-5:2014 Electrical insulating materials — Thermal endurance properties — Part 5:Determination of relative thermal endurance index(RTE) of an insulating material
- KS C IEC 60512-4-3-2002(2013) Connectors for electronic equipment-Tests and measurements-Part 4-3:Voltage stress tests-Test 4c:Voltage proof ofpre-insulated crimp barrels
- KS C IEC 60512-4-3-2014 Connectors for electronic equipment-Tests and measurements-Part 4-3:Voltage stress tests-Test 4c:Voltage proof ofpre-insulated crimp barrels
- KS C IEC 60216-5-2019 Electrical insulating materials — Thermal endurance properties — Part 5:Determination of relative thermal endurance index(RTE) of an insulating material
- KS C 2128-1996(2016) Testing methods for impact resistance of plastics and electrical insulating materials
- KS C IEC 61251:2019 Electrical insulating materials and systems — AC voltage endurance evaluation
- KS F 2288-2001 Method of test for heat insulation of equipment units for dwellings
- KS C IEC 60245-3-2013(2018) Rubber insulated cables of rated voltages up to and including 450/750 V-Part 3:Heat resistant silicone insulated cables
- KS F 2461-2000 Testing method for compressive strength of lightweight insulating concrete
- KS F 2461-1985 Testing method for compressive strength of lightweight insulating concrete
- KS F 2288-1981 Method of test for heat insulation of equipment units for dwellings
- KS C 3833-2006(2021) 6.6 kV strain insulators
- KS C 3801-2003(2018) Insulator test method
- KS C IEC 60245-3:2013 Rubber insulated cables of rated voltages up to and including 450/750 V-Part 3:Heat resistant silicone insulated cables
- KS C IEC 61251:2002 Electrical insulating materials-A.C. voltage endurance evaluation-Introduction
- KS C IEC 60245-3-2023 Rubber insulated cables of rated voltages up to and including 450/750 V-Part 3:Heat resistant silicone insulated cables
- KS C IEC 60245-3:2005 Rubber insulated cables-Rated voltages up to and including 450/750 V-Part 3: Heat resistant silicone insulated cables
- KS C IEC 61621-2019 Dry, solid insulating materials — Resistance test to high-voltage, low-current arc discharges
- KS W 5111-1996 ISOLATED TRANSFORMERS
BR-ABNT
- ABNT 19-2.1-003-1980 Pressure resistance test of insulating refractory bricks at normal temperature
- ABNT MB-259-1979 Refractory materials. Special marl detection for insulating refractory products
- ABNT P-MB-330-1963 Test method for testing the dielectric strength of insulating mineral oils
YU-JUS
- JUS N.S5.607-1985 Die/ectric strength tests ofultrasonlc medlcal dlagnostfc eguipment
- JUS N.A5.130-1984 Testitng of insulating materials for electrical purposes. Method of testing the resistance of insulating materials to tow voltage electric are
- JUS N.H1.013-1985 Power transformers. Insulation levek and dielectric tests
- JUS N.F1.437-1993 Radio interference test on high-voltage insulators
- JUS N.C0.075-1984 Electrical pover and lighting. Testing of insulated conductors and cables. Fire resistance
- JUS N.C0.074-1987 Electric povver and lighting. Testing of insulated conductors and cables. Resistance to oil
- JUS N.C0.057-1979 Tests ofinsulated conductors and cables. Stability ofinsulation to fillers
- JUS N.H1.113-1990 Power transformers. Insulation levels and dielectric tescs. Extemal clearances in air
CZ-CSN
- CSN 34 6471-1986 Test methods for electric insulating materials. Test method for determination of resistance insulating materials to high-voltage arc
- CSN 34 6501-1985 Tests of thermal endurance of electrical insulating materials
- CSN 34 8171-1965 Strain insulators
- CSN 67 3150 Cast.07-1975 Resistance to insulating liquid
- CSN 34 8173-1965 Strain insulators TB
- CSN 34 8172-1965 Strain insulators TA
- CSN 34 6410-1961 Tost for evaluating the thermal endurance of electrical insulating materials
- CSN 34 8033-1978 Switching impulse tests on high-voltage insulate re
SE-SIS
- SIS SS IEC 506:1982 Insulators — High-voltage insulators — Switching impulse tests
- SIS SS 404 03 21-1986 Insulating oils - Method for determination of the electric strength of insulating oils
- SIS SS IEC 897:1988 Insulating liquids — Methods for the determination of the lightning impulse breakdown voltage of insulating liquids
- SIS SS IEC 167:1982 Methods of test for the determination of the insulation resistance of solid insulating materials
- SIS SS IEC 233:1984 Insulators — Tests ort hollow insulators for use in electrical equipment
- SIS SS IEC 255-5:1983 Relays - Insulation tests
- SIS SS 404 09 24-1992 Solid insulating materials - Methods of test for electric strength of solid insulating materials
RU-GOST R
- GOST 15634.4-1970 Magnet wire. Methods of the breakdown voltage test
- GOST 12268-1979 Electrical insulating board. Methods for determination of test voltage resistance, surface discharge resistance and compressibility under pressure
- GOST R IEC 60245-3-1997 Rubber insulated cables of rated voltages to 450/750 V including. Heat resistant silicone insulated cables
- GOST 14950-1975 Insulation construction of electrical machinery with previously insulated preformed winding sections. Test method for determination of thermal enolurance
- GOST IEC 60245-3-2011 Rubber insulated cables of rated voltages to 450/750 V including. Heat resistant silicone insulated cables
American National Standards Institute (ANSI)
- ANSI/ASTM D1389:2007 Test Method for Proof-Voltage Testing of Thin Solid Electrical Insulating Materials
- ANSI/ASTM A717/A 717M:2001 Test Method for Surface Insulation Resistivity of Single-Strip Specimens
- ANSI/ASTM D2275:2001 Test Method for Voltage Endurance of Solid Electrical Insulating Materials Subjected to Partial Discharges (Corona) on the Surface (10.01)
- ANSI/ASTM D1932:2013 TEST METHOD FOR THERMAL ENDURANCE OF FLEXIBLE ELECTRICAL INSULATING VARNISHES
SCC
- BS 3297-1:1974 High voltage post insulators. Tests
- CEI EN 61621:1998 Dry, solid insulating materials - Resistance test to high-voltage, low-current arc discharges
- CEI EN 60512-4-3:2003 Connectors for electronic equipment - Tests and measurements - Part 4-3: Voltage stress tests - Test 4c: Voltage proof of pre-insulated crimp barrels
- DANSK DS/EN 60512-4-3:2002 Connectors for electronic equipment - Tests and measurements - Part 4-3: Voltage stress tests - Test 4c: Voltage proof of pre-insulated crimp barrels
- CEI EN IEC 60437:2024 Radio interference test on high-voltage insulators
- CEI EN 60437:1998 Radio interference test on high-voltage insulators
- DANSK DS/EN 60437:1997 Radio interference test on high-voltage insulators
- CAN/ULC-S129-2006 STANDARD METHOD OF TEST FOR SMOULDER RESISTANCE OF INSULATION (BASKET METHOD)
- CEI EN 60512-19-1:2011 Connectors for electronic equipment - Tests and measurements Part 19-1: Chemical resistance tests - Test 19a: Fluid resistance of preinsulated crimp barrels
- ULC S129-1995(R2001) Standard Method Of Test For Smoulder Resistance Of Insulation (Basket Method)
- IEC TS 61251:1993 Electrical insulating materials - A.C. voltage endurance evaluation - Introduction
- DANSK DS/EN 60512-19-1:2010 Connectors for electronic equipment - Tests and measurements - Part 19-1: Chemical resistance tests - Test 19a: Fluid resistance of pre-insulated crimp barrels
- UNE-EN 1094-5:1996 INSULATING REFRACTORY PRODUCTS. PART 5: DETERMINATION OF COLD CRUSHING STRENGTH.
- AENOR UNE-EN 60437:1999 RADIO INTERFERENCE TEST ON HIGH-VOLTAGE INSULATORS.
- IEC TS 60941:1988 Mechanical endurance functional tests for electrical insulation systems
- DANSK DS/EN 60216-2:2006 Electrical insulating materials - Thermal endurance properties - Part 2: Determination of thermal endurance properties of electrical insulating materials - Choice of test criteria
- AENOR UNE 21131:1980 TESTING OF INSULATORS FOR HIGH VOLTAGE WITH MANEUVER TYPE IMPULSES
- IEC 60216-2:1974 Guide for the determination of thermal endurance properties of ekectrical insulating materials - Part 2: List of materials and available tests Guide for the determination of thermal endurance properties of electrical insulating materials.
- CEI EN 60216-2:2006 Electrical insulating materials - Thermal endurance properties - Part 2: Determination of thermal endurance properties of electrical insulating materials - Choice of test criteria
- DANSK DS/EN 60216-5:2008 Electrical insulating materials – Thermal endurance properties – Part 5: Determination of relative thermal endurance index (RTE) of an insulating material
- CEI EN 60216-5:2012 Electrical insulating materials - Thermal endurance properties Part 5: Determination of relative thermal endurance index (RTE) of an insulating material
- DANSK DS/EN 61251:2016 Electrical insulating materials and systems - A.C. voltage endurance evaluation
- CEI EN 61251:2016 Electrical insulating materials and systems - A.C. voltage endurance evaluation
- MIL MIL-S-81824/4-1990 SPLICES, ELECTRIC, PERMANENT, CRIMP STYLE, COPPER, INSULATED, ENVIRONMENT RESISTANT, SPLICE, SHIELD, SOLDER TYPE, INSULATED, CLASS I
- CSA C22.2 No.198-M1982-1982 Extruded Insulating Tubing
- DANSK DS/EN 60156:1995 Insulating liquids - Determination of the breakdown voltage at power frequency - Test method
- CEI EN 60156:1998 Insulating liquids - Determination of the breakdown voltage at power frequency - Test method
- BS 171-3:1987 Power transformers-Specification for insulation levels and dielectric tests
American Society for Testing and Materials (ASTM)
- ASTM D1389-07 Standard Test Method for Proof-Voltage Testing of Thin Solid Electrical Insulating Materials
- ASTM D1389-97a(2004) Standard Test Method for Proof-Voltage Testing of Thin Solid Electrical Insulating Materials
- ASTM D3251-19 Standard Test Method for Thermal Endurance Characteristics of Electrical Insulating Varnishes Applied Over Film-Insulated Magnet Wire
- ASTM D495-99 Standard Test Method for High-Voltage, Low-Current, Dry Arc Resistance of Solid Electrical Insulation
- ASTM D495-99(2004) Standard Test Method for High-Voltage, Low-Current, Dry Arc Resistance of Solid Electrical Insulation
- ASTM D3005-99(2004) Standard Specification for Low-Temperature Resistant Vinyl Chloride Plastic Pressure-Sensitive Electrical Insulating Tape
- ASTM F1116-03(2008) Standard Test Method for Determining Dielectric Strength of Dielectric Footwear
- ASTM D495-22 Standard Test Method for High-Voltage, Low-Current, Dry Arc Resistance of Solid Electrical Insulation
- ASTM D2307-07a Standard Test Method for Thermal Endurance of Film-Insulated Round Magnet Wire
- ASTM D2307-21 Standard Test Method for Thermal Endurance of Film-Insulated Round Magnet Wire
- ASTM E2189-10e1 Standard Test Method for Testing Resistance to Fogging in Insulating Glass Units
- ASTM D2307-95 Standard Test Method for Thermal Endurance of Film-Insulated Round Magnet Wire
KR-KS
- KS R 9197-1996(2016)(英文版) Test methods for insulation resistance and withstand voltage of railway rolling stock
- KS P 8010-2018(2023) Testing method for withstand voltage of personal protective equipment and insulating devices
- KS C IEC 60437-2020 Radio interference test on high-voltage insulators
- KS C IEC 60216-2-2008(2023) Electrical insulating materials-Thermal endurance properties-Part 2:Determination of thermal endurance properties of electrical insulating materials-Choice of test criteria
- KS C IEC 61251-2019 Electrical insulating materials and systems — AC voltage endurance evaluation
- KS C IEC 60245-3-2013(2023) Rubber insulated cables of rated voltages up to and including 450/750 V-Part 3:Heat resistant silicone insulated cables
GSO
- GSO ISO 11432:2007 Building construction - Sealants – Determination of resistance to compression
- GSO IEC 61621:2015 Dry, solid insulating materials - Resistance test to high-voltage, low-current arc discharges
- OS GSO IEC 60512-4-3:2015 Connectors for electronic equipment - Tests and measurements - Part 4-3: Voltage stress tests - Test 4c: Voltage proof of pre-insulated crimp barrels
- BH GSO IEC 61621:2016 Dry, solid insulating materials - Resistance test to high-voltage, low-current arc discharges
- BH GSO IEC 60512-4-3:2016 Connectors for electronic equipment - Tests and measurements - Part 4-3: Voltage stress tests - Test 4c: Voltage proof of pre-insulated crimp barrels
- DL/T 474.6-1992 Guidelines for the implementation of on-site insulation tests - Transformer operating wave induced withstand voltage test
- OS GSO IEC 60216-2:2010 Electrical insulating materials - Thermal endurance properties - Part 2: Determination of thermal endurance properties of electrical insulating materials - Choice of test criteria
- OS GSO IEC 60506:2002 Switching Impulse Tests on High-Voltage Insulators
- GSO IEC 60506:2002 Switching Impulse Tests on High-Voltage Insulators
- OS GSO IEC 60512-19-1:2013 Connectors for electronic equipment - Tests and measurements - Part 19-1: Chemical resistance tests - Test 19a: Fluid resistance of pre-insulated crimp barrels
- GSO IEC 60216-2:2010 Electrical insulating materials - Thermal endurance properties - Part 2: Determination of thermal endurance properties of electrical insulating materials - Choice of test criteria
- GSO IEC 60512-4-3:2015 Connectors for electronic equipment - Tests and measurements - Part 4-3: Voltage stress tests - Test 4c: Voltage proof of pre-insulated crimp barrels
- GSO IEC 61975:2014 High-voltage direct current (HVDC) installations - System tests
- DL/T 557-1994 High voltage line insulator steep wave impulse withstand test - definition, test method and criterion
- GSO IEC 61109:2014 Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria
HU-MSZT
- MSZ 15747/11-1982 Electrical insulation material testing. voltage test
- MSZ 263/6-1983 High voltage porcelain insulator insulated hollow structure, technical requirements and testing
- MSZ 20880/2-1984 Solid electrical insulating materials. Determine the insulation strength. Impulse voltage test
- MI 9250/2-1981 Insulation coordination guidelines. Test voltage detection
- MSZ 263/1-1976 High voltage insulation. Insulation of free conductors
British Standards Institution (BSI)
- BS EN ISO 8895:2006 Shaped insulating refractory products - Determination of cold crushing strength
- BS EN 61621:1997 Dry, solid insulating materials. Resistance test to high-voltage, low-current arc discharges
- BS EN 60216-2:2005 Electrical insulating materials. Thermal endurance properties. Determination of thermal endurance properties of electrical insulating materials. Choice of test criteria
- BS 6470:1984 Method for determination of water in insulating oils, and in oil-impregnated paper and pressboard
- BS EN 60216-5:2008 Electrical insulating materials - Thermal endurance properties - Part 5: Determination of relative thermal endurance index (RTE) of an insulating material
- BS EN 60216-5:2003 Electrical insulating materials - Thermal endurance properties - Determination of relative thermal endurance index (RTE) of an insulating material
- BS EN 61251:2016 Electrical insulating materials and systems. A.C. voltage endurance evaluation
- BS 7808:1995 Electrical insulating materials - A.C. voltage endurance evaluation - Introduction
- 20/30363286 DC BS EN 60437. Radio interference test on high-voltage insulators
- BS EN 1094-1:2008 Insulating refractory products - Terminology, classification and methods of test for high temperature insulation wool products
- BS EN 60156:1996 Insulating liquids. Determination of the breakdown voltage at power frequency. Test method
- BS EN IEC 60216-5:2022 Electrical insulating materials. Thermal endurance properties. Determination of relative temperature index (RTI) of an insulating material
Association Francaise de Normalisation
- NF EN 61621:1998 Dry Solid Insulating Materials - High Voltage, Low Current Arc Discharge Resistance Test
- NF C26-302*NF EN 60216-2:2006 Electrical insulating materials - Thermal endurance properties - Part 2 : determination of thermal endurance properties of electrical insulating materials - Choice of test criteria
- NF C26-227:1992 METHODS OF TEST FOR ELECTRIC STRENGTH OF SOLID INSULATING MATERIALS. PART 2 : ADDITIONAL REQUIREMENTS FOR TESTS USING DIRECT VOLTAGE.
- NF EN 60437:2000 Radio disturbance testing of high voltage insulators
- NF EN IEC 60437:2024 Radio disturbance testing of high voltage insulators
- NF EN 60512-19-1:2011 Connectors for electronic equipment - Tests and measurements - Part 19-1: chemical resistance tests - Test 19a: fluid resistance of pre-insulated crimp terminals
- NF C26-250/A1:1983 Méthodes d'essai des matières isolantes - Aptitude au poinçonnage.
- NF EN 60216-2:2006 Electrical insulating materials - Thermal endurance properties - Part 2: determination of thermal endurance properties of electrical insulating materials - Choice of test criteria
- NF EN 60512-4-3:2002 Connectors for electronic equipment - Tests and measurements - Part 4-3: dielectric stress tests - Test 4c: withstand voltage for pre-insulated crimping drums
- NF C26-351*NF EN 61251:2016 Electrical insulating materials and systeme - A.C. voltage endurance evaluation
- NF EN 50209:2000 Testing the insulation of bars and coils of high voltage machines
- NF C26-305*NF EN 60216-5:2008 Electrical insulating materials - Thermal endurance properties - Part 5 : determination of relative thermal endurance index (RTE) of an insulating material
- NF C26-305:2003 Electrical insulating materials - Thermal endurance properties - Part 5 : determination of relative thermal endurance index (RTE) of an insulating material.
- NF C26-210:1965 Testing methods for insulating materials. Measurement of total insulation resistance.
- NF EN 61251:2016 Electrical insulating systems and materials - Evaluation of endurance to alternating voltage
FI-SFS
- SFS 5275-1987 Insulator. Plastic insulation testing
- SFS 5454-1988 Pipe insulation, slot insulation and equipment insulation. Testing of insulating materials, insulating elements and coatings
PL-PKN
- PN E06323-1990 High yoltage insulators Ceramic rod insulators Ultrasonic and texture tests
- PN E04410-23-1986 Electroinsulating varnishes Test methods Testing of arc resistance and tracking resistance
- PN E04442-1989 Solid insulating materials Test for the resistance to tracking at high voltage and inclined specimen
- PN E04063-06-1987 On-Ioad tap changers Test methods Dielectric strength
- PN E04443-1965 Solid elec?rical insula?ing ma?erials Testing of highcurrent and lowvol?age arc resis?ance
- PN E91040-1990 High voltage insulators Line post insulators LWP
Japanese Industrial Standards Committee (JISC)
- JIS E 4014:2007 Rolling stock -- Test methods for insulation resistance and withstand voltage
- JIS E 4014:2012 Rolling stock -- Test methods for insulation resistance and withstand voltage
- JIS E 4014:1989 Test methods for insulation resistance and withstand voltage of railway rolling stock
- JIS T 8010:1979 Testing method for withstand voltage of personal protective equipment and insulating devices
- JIS T 8010:2001 Testing method for withstand voltage of personal protective equipment and insulating devices
- JIS T 8010:2017 Testing method for withstand voltage of personal protective equipment and insulating devices
- JIS E 3021:1999 Insulation resistance and withstand voltage testing methods of parts for railway signaling
- JIS C 3826:1994 6.6 kV strain insulators
- JIS C 3810:1992 Normal type and anti-pollution type suspension insulators
- JIS C 9742:2000 Isolating transformers and safety isolating transformers -- Requirements
- JIS C 3663-3:1998 Rubber insulated cables -- Rated voltages up to and including 450/750 V -- Part 3: Heat resistant silicone insulated cables
- JIS C 5402-4-3:2005 Connectors for electronic equipment -- Tests and measurements -- Part 4-3: Voltage stress tests -- Test 4c: Voltage proof of pre-insulated crimp barrels
AENOR
- UNE-EN 60512-4-3:2002 Connectors for electronic equipment - Tests and measurements -- Part 4-3: Voltage stress tests - Test 4c: Voltage proof of pre-insulated crimp barrels.
- UNE-EN 60437:1999 RADIO INTERFERENCE TEST ON HIGH-VOLTAGE INSULATORS.
- UNE 21570:1993 TEST PROCEDURE FOR THERMAL ENDURANCE OF INSULATING VARNISHES. ELECTRIC STRENGTH METHOD.
- UNE 81012:1985 INSULANT CAPS FOR INSULATORS IN LOW VOLTAGE LINES
- UNE-EN 50209:1999 TEST OF INSULATION OF BARS AND COILS OF HIGH-VOLTAGE MACHINES.
Danish Standards Foundation
- DS/EN 60512-4-3:2002 Connectors for electronic equipment - Tests and measurements - Part 4-3: Voltage stress tests - Test 4c: Voltage proof of pre-insulated crimp barrels
- DS/EN 60437:1998 Radio interference test on high-voltage insulators
- DS/EN 60216-2:2006 Electrical insulating materials – Thermal endurance properties – Part 2: Determination of thermal endurance properties of electrical insulating materials – Choice of test criteria
- DS/EN 60216-5:2008 Electrical insulating materials - Thermal endurance properties - Part 5: Determination of relative thermal endurance index (RTE) of an insulating material
GM Europe
- GME 60294-1993 Testing the chemical resistance of insulating mats (English/German)
ES-UNE
- UNE-EN 60216-2:2005 Electrical insulating materials - Thermal endurance properties -- Part 2: Determination of thermal endurance properties of electrical insulating materials - Choice of test criteria (Endorsed by AENOR in December of 2005.)
- UNE-EN 60512-19-1:2010 Connectors for electronic equipment - Tests and measurements -- Part 19-1: Chemical resistance tests - Test 19a: Fluid resistance of pre-insulated crimp barrels (Endorsed by AENOR in September of 2010.)
- UNE-EN 61251:2016 Electrical insulating materials and systems - A.C. voltage endurance evaluation (Endorsed by AENOR in April of 2016.)
- UNE-EN 50209:1999 ERRATUM TEST OF INSULATION OF BARS AND COILS OF HIGH-VOLTAGE MACHINES.
- UNE-EN 60216-5:2008 Electrical insulating materials - Thermal endurance properties -- Part 5: Determination of relative thermal endurance index (RTE) of an insulating material (Endorsed by AENOR in September of 2008.)
Institute of Electrical and Electronics Engineers (IEEE)
- IEEE 82-2002 Standard Test Procedure for Impulse Voltage Tests on Insulated Conductors
- IEEE 82-1994 Test procedure for impulse voltage tests on insulated conductors
- IEEE 82-1963 IEEE Test Procedure for Impulse Voltage Tests on Insulated Conductors
- IEEE Std 82-1963 IEEE Test Procedure for Impulse Voltage Tests on Insulated Conductors
- IEEE Std 82-2002 IEEE Standard Test Procedure for Impulse Voltage Tests on Insulated Conductors
- ANSI/IEEE Std 930-1987 IEEE Guide for the Statistical Analysis of Electrical Insulation Voltage Endurance Data
- IEEE Std 82-1994 IEEE Standard test procedure for impulse voltage tests on insulated conductors
- IEEE 82/COR-2009 Errata to IEEE Standard Test Procedure for Impulse Voltage Tests on Insulated Conductors
Institute of Interconnecting and Packaging Electronic Circuits (IPC)
- IPC TM-650 2.5.7.2-2007 Dielectric Withstanding Voltage (HiPot Method) - Thin Dielectric Layers for Printed Circuit Boards (PCBs)
International Electrotechnical Commission (IEC)
- IEC 60216-2:2005 Electrical insulating materials - Thermal endurance properties - Part 2: Determination of thermal endurance properties of electrical insulating materials - Choice of test criteria
- IEC 61251:2015 Electrical insulating materials and systems - AC voltage endurance evaluation
- IEC 61621:1997 Dry, solid insulating materials - Resistance test to high-voltage, low current arc discharges
- IEC 60216-5:2003 Electrical insulating materials - Thermal endurance properties - Part 5: Determination of relative thermal endurance index (RTE) of an insulating material
- IEC 60245-3:1994 Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 3: Heat resistant silicone insulated cables
- IEC TS 61251:2008 Electrical insulating materials - A.C. voltage endurance evaluation - Introduction
- IEC 61109:2008 Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1000 V - Definitions, test methods and acceptance criteria
- IEC 60245-3:1980 Rubber insulated cables of rated voltages up to and including 450/750 V. Part 3 : Heat resistant silicone rubber insulated cables
Indonesia Standards
- SNI 04-3868-2001 Radio interference test for high voltage insulators
- SNI IEC 60245-3:2012 Rubber insulated cables – Rated voltages up to and including 450/750 V. Part 3: Heat resistant silicone insulated cables
European Committee for Standardization (CEN)
- EN ISO 8895:2006 Shaped insulating refractory products - Determination of cold crushing strength (ISO 8895:2004)
- EN 60216-5:2003 Electrical insulating materials — Thermal endurance properties — Part 5: Determination of relative thermal endurance index (RTE) of an insulating material
IEEE - The Institute of Electrical and Electronics Engineers@ Inc.
- IEEE 41-1930 Insulator Tests
- IEEE 41-1944 Insulator Tests
- IEEE 930-1987 Guide for the Statistical Analysis of Electrical Insulation Voltage Endurance Data
PT-IPQ
- NP 2887-1984 Circuit insulation materials and related accessories. Vibration testing of high voltage insulators
Lithuanian Standards Office
- LST EN 61621-2001 Dry solid insulating materials. Resistance test to high-voltage, low-current arc discharges (IEC 61621:1997)
- LST EN 60512-4-3-2003 Connectors for electronic equipment. Tests and measurements. Part 4-3: Voltage stress tests. Test 4c: Voltage proof of pre-insulated crimp barrels (IEC 60512-4-3:2002)
- LST EN 60216-2-2005 Electrical insulating materials. Thermal endurance properties. Part 2: Determination of thermal endurance properties of electrical insulating materials. Choice of test criteria (IEC 60216-2:2005)
- LST EN 60437-2001 Radio interference test on high-voltage insulators (IEC 60437:1997)
European Committee for Electrotechnical Standardization(CENELEC)
- EN 61251:2016 Electrical insulating materials and systems - A.C. voltage endurance evaluation
- HD 570 S1-1990 Test Procedure for Thermal Endurance of Insulating Varnishes - Electric Strength Method
- EN IEC 61462:2023 Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with AC rated voltage greater than 1 000 V AC and D.C. voltage greater than 1500V - Definitions, test methods, acceptance criteria and design recomme...
- HD 568 S1-1990 Methods of Test for the Determination of the Insulation Resistance of Solid Insulating Materials
- EN 60216-5:2008 Electrical insulating materials - Thermal endurance properties - Part 5: Determination of relative thermal endurance index (RTE) of an insulating material
United States Navy
- NAVY QPL-16305-32-1998 BRICK, REFRACTORY, INSULATING
- NAVY MIL-C-2861 E-1988 CEMENT, INSULATION, HIGH TEMPERATURE
VN-TCVN
- TCVN 6306-3-2006 Power transformers.Part 3: Insulation levels and dielectric tests and external clearances in air
SAE - SAE International
- SAE AS81824A-A1-2005 Splices@ Electric@ Permanent@ Crimp Style@ Copper@ Insulated@ Environment Resistant
- SAE AS81824/4-2004 SPLICES@ ELECTRIC@ PERMANENT@ CRIMP STYLE@ COPPER@ INSULATED@ ENVIRONMENT RESISTANT@ SPLICE@ SHIELD@ SOLDER TYPE@ INSULATED@ CLASS 1
US-FCR
- FCR COE RPMAS 67450-1978 TESTING OF ELECTRICAL INSULATING OIL
CL-INN
- INDITECNOR 55-33ch-1959 Insulating Tape: Test
Standard Association of Australia (SAA)
- AS 4435.1:1996 Insulators - Composite for overhead power lines - Voltages greater than 1000 V a.c. - Definitions, test methods and acceptance criteria for string insulator units
- AS 4435.1:1996(R2016) Insulators - Composite for overhead power lines - Voltages greater than 1000 V a.c. - Definitions, test methods and acceptance criteria for string insulator units
- AS 2374.3.0:1982 Power transformers - Insulation levels and dielectric tests - General requirements
- AS 2374.3.1:1992 Power transformers - Insulation levels and dielectric tests - External clearances in air
TR-TSE
- TS 2293-1976 P L A STIC S METHOD OF TEST FOR HIGH - VOLTAGE - LOW CURRENT DRY ARC RESISTANCE OF SOLID ELECTRICAL INSULATION
IEC - International Electrotechnical Commission
- IEC 60437:1973 Radio Interference Test on High-Voltage Insulators (Edition 1.0)
- TS 61251-2008 Electrical insulating materials – A.C. voltage endurance evaluation – Introduction (Edition 2.0)
- IEC 60438:1973 Tests and Dimensions for High-Voltage D.C. Insulators (Edition 1.0)
German Institute for Standardization
- DIN EN 60216-5:2009 Electrical insulating materials - Thermal endurance properties - Part 5: Determination of relative thermal endurance index (RTE) of an insulating material (IEC 60216-5:2008); German version EN 60216-5:2008
- DIN EN 61109:2009 Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1000 V - Definitions, test methods and acceptance criteria (IEC 61109:2008); German version EN 61109:2008
Society of Automotive Engineers (SAE)
- SAE AS81824A-2009 Splices, Electric, Permanent, Crimp Style, Copper, Insulated, Environment Resistant
- SAE AS81824B-2010 Splices, Electric, Permanent, Crimp Style, Copper, Insulated, Environment Resistant
- SAE AS81824A_A1-2005 Splices, Electric, Permanent, Crimp Style, Copper, Insulated, Environment Resistant
- SAE AS81824/4A-2022 SPLICES, ELECTRIC, PERMANENT, CRIMP STYLE, COPPER, INSULATED, ENVIRONMENT RESISTANT, SPLICE, SHIELD, SOLDER TYPE, INSULATED, 150 °C
TH-TISI
- TIS 955.3-2008 Rubber insulated cables.rated voltages up to and including 450/750 v.part 3: heat resistant silicone insulated cables
RO-ASRO
- STAS 1703/3-1980 Power transform ers INSULATING LEVELS AND DIELECTRIC TESTS
Insulated Cable Engineers Association (ICEA)
- ICEA P-47-434-1965 Pressurization Characteristics of Polyethylene-Insulated and - Jacketed Telephone Cables
Pressure tester,Insulation Testing,Insulating Glove Test,Hipot test high voltage,Insulation resistance test,Insulation resistance test,Pressure test,Pressure test,Insulation test,Insulation resistance test,Insulation test equipment,Test methods for insulation resistance and withstand voltage,Hipot tester,Insulation withstand voltage test,Insulation withstand voltage test method,Dielectric withstand voltage,Photovoltaic insulation withstand voltage,Insulation withstand voltage test