quadruple ion trap mass spectrometry
quadruple ion trap mass spectrometry, Total:81 items.
The international standard classification for "quadruple ion trap mass spectrometry" includes: Other standards related to analytical chemistry , Chemical reagents , Chemical analysis , Chemical analysis of metals , Chemical laboratories. Laboratory equipment , Measuring instruments .
The Chinese standard classification for "quadruple ion trap mass spectrometry" includes: Material composition analysis instrument and environment detection instrument in general , Special electronic technology material , Basic standards and general methods , Semimetal and semiconductor material analysis method , Hygiene, safety and labor protection , Electrochemical, thermochemistry and optical profile type analyzer , Mass spectrometer, liquid spectrometer, energy spectrometer and combined devices of them , Chemical Measurement , Analysis methods for toxic substances in water , Hydrogeological survey .
Zhejiang Provincial Standard of the People's Republic of China
- DB33/T 543-2005 Method for Determination of Multi-residue Pesticides in Fruits and Vegetables by Gas Chromatography Ion Trap Mass Spectrometry
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
- GB/T 11446.7-1997 Test method for trace chloride, nitrate, phosphate, sulfate in electronic grade water by ion-chromatography
- GB/T 35925-2018 Determination of impurity fluorine ion in water soluble chemicals—Ion chromatography method
- GB/T 31197-2014 Inorganic chemicals for industrial use-Determination of impurity anions - Ion chromatography method
- GB/T 11446.7-2013 Test Method for Trace Anion in Electronic Grade Water by Ion Chromatography
- GB/T 37049-2018 Test method for the content of metal impurity in electronic grade polysilicon—Inductively coupled-plasma mass spectrometry method
- GB/T 43966-2024 General rules for high performance liquid chromatography-quadrupole inductively coupled plasma-mass spectrometry
- GB/T 34826-2017 Method of performance testing for quadrupole inductively coupled plasma mass spectrometer
- GB/T 40129-2021 Surface chemical analysis—Secondary ion mass spectrometry—Calibration of the mass scale for a time-of-flight secondary ion mass spectrometer
- GB/T 37837-2019 General rules for quadrupole inductively coupled plasma mass spectrometry
Group Standards of the People's Republic of China
- T/DLAS 004-2021 Determination of five kinds of selenium in selenium-enriched agricultural products by ion chromatography-inductively coupled plasma mass spectrometry
- T/ZJATA 0023-2024 Determination of perchlorate in water Ion chromatography-mass spectrometry/mass spectrometry
- T/CIMA 0023-2020 Technical requirements for vehicle-mounted inductively coupled plasma quadrupole mass spectrometer
- T/CNIA 0061-2020 Determination of Impurity Content in Silicon Tetrachloride for Silicon Epitaxy by Inductively Coupled Plasma Mass Spectrometry
- T/SXQCA 001-2023 Water quality-Determination of water soluble cations(Sr2+、Ba2+) -Ion chromatography
- T/CIS 17004-2020 Ambient ionization device
- T/NAIA 0160-2022 Determination of total sulfur dioxide in wine by triple quadrupole inductively coupled plasma mass spectrometry
- T/BPMA 32-2004 Determination of chlorate and perchlorate in leek by ion chromatography-mass spectrometry/mass spectrometry
- T/NAIA 0169-2022 Water Quality Determination of Ammonia Nitrogen by Ion Chromatography
National Metrological Technical Specifications of the People's Republic of China
- JJF 1159-2006 Calibration Specification for Quadrupole Inductively Coupled Plasma Mass Spectrometers
Professional Standard - Environmental Protection
- HJ/T 84-2001 Water quality -- Determination of inorangic anions -- Ion chromatography method
Qinghai Provincial Standard of the People's Republic of China
- DB63/T 1611-2017 Determination of Impurity Content in Silicon Tetrachloride as Raw Material of Optical Fiber Preform by Inductively Coupled Plasma Mass Spectrometry
Henan Provincial Standard of the People's Republic of China
- DB41/T 1926-2019 High oleic acid peanut seed quality standard for grade 4
- DB41/T 997.6-2014 Grade 4 Seed Quality Standards for Crops Part 6: Millet
Yunnan Provincial Standard of the People's Republic of China
- DB53/T 981-2020 Thermal stimulation current test method for trap charge and trap energy level of silicone rubber in composite insulator umbrella cover
Professional Standard - Commodity Inspection
- SN/T 2210-2008 Determination of hexavalent chromium in health foods - IC-ICP-MS method
Professional Standard - Geology
- DZ/T 0064.51-1993 Groundwater quality test methods - the determination of chloridion, fluorinion, bromide ion, nitrate radical and sulfate radical with ion chromatography method
Professional Standard - Medicine
- YY/T 1740.3-2024 Clinical mass spectrometer-Part 3 : Inductively coupled plasma mass spectrometry
Professional Standard - Agriculture
- 73药典 四部-2015 0412 Inductively coupled plasma mass spectrometry
- 53药典 四部-2020 0412 Inductively coupled plasma mass spectrometry
American Water Works Association (AWWA)
- AWWA WQTC62560 Analysis of Less Volatile Compounds Using Ion Trap Mass Spectrometry Coupled with Modified Purge-Trap Technique
- AWWA WQTC52856 A Broad Spectrum Taste and Odor Analysis Using Solid Phase Microextraction (SPME) and Ion Trap Detection With Selected Ion Storage (SIS)
- AWWA QTC98327 The Performance of a Purge and Trap-Gas Chromatography/Ion Trap Mass Spectrometry Method for the Routine Analysis of Cyanogen Chloride in Several Hundred Municipal Drinking Water Samples
American Society for Testing and Materials (ASTM)
- ASTM E1504-92(1996) Standard Practice for Reporting Mass Spectral Data in Secondary Ion Mass Spectrometry (SIMS)
- ASTM E1504-92(2001) Standard Practice for Reporting Mass Spectral Data in Secondary Ion Mass Spectrometry (SIMS)
- ASTM E1504-06 Standard Practice for Reporting Mass Spectral Data in Secondary Ion Mass Spectrometry (SIMS)
- ASTM E1504-11 Standard Practice for Reporting Mass Spectral Data in Secondary Ion Mass Spectrometry (SIMS)
- ASTM E1635-06(2011) Standard Practice for Reporting Imaging Data in Secondary Ion Mass Spectrometry (SIMS)
- ASTM C1474-00(2011) Standard Test Method for Analysis of Isotopic Composition of Uranium in Nuclear-Grade Fuel Material by Quadrupole Inductively Coupled Plasma-Mass Spectrometry
- ASTM C1474-00 Standard Test Method for Analysis of Isotopic Composition of Uranium in Nuclear-Grade Fuel Material by Quadrupole Inductively Coupled Plasma-Mass Spectrometry
- ASTM C1474-00(2006)e1 Standard Test Method for Analysis of Isotopic Composition of Uranium in Nuclear-Grade Fuel Material by Quadrupole Inductively Coupled Plasma-Mass Spectrometry
- ASTM E1635-06 Standard Practice for Reporting Imaging Data in Secondary Ion Mass Spectrometry (SIMS)
- ASTM E1881-12 Standard Guide for Cell Culture Analysis with SIMS
- ASTM C1474-19 Standard Test Method for Analysis of Isotopic Composition of Uranium in Nuclear-Grade Fuel Material by Quadrupole Inductively Coupled Plasma-Mass Spectrometry
- ASTM E1438-91(1996) Standard Guide for Measuring Widths of Interfaces in Sputter Depth Profiling Using SIMS
- ASTM E1438-91(2001) Standard Guide for Measuring Widths of Interfaces in Sputter Depth Profiling Using SIMS
- ASTM E1881-06 Standard Guide for Cell Culture Analysis with SIMS
British Standards Institution (BSI)
- BS ISO 23830:2008 Surface chemical analysis - Secondary-ion mass spectrometry - Repeatability and constancy of the relative-intensity scale in static secondary-ion mass spectrometry
- BS ISO 18114:2003 Surface chemical analysis - Secondary-ion mass spectrometry - Determination of relative sensitivity factors from ion-implanted reference materials
- BS ISO 17862:2013 Surface chemical analysis. Secondary ion mass spectrometry. Linearity of intensity scale in single ion counting time-of-flight mass analysers
- BS ISO 20411:2018 Surface chemical analysis. Secondary ion mass spectrometry. Correction method for saturated intensity in single ion counting dynamic secondary ion mass spectrometry
- BS ISO 13084:2011 Surface chemical analysis. Secondary-ion mass spectrometry. Calibration of the mass scale for a time-of-flight secondary-ion mass spectrometer
- BS ISO 13084:2018 Surface chemical analysis. Secondary ion mass spectrometry. Calibration of the mass scale for a time-of-flight secondary ion mass spectrometer
- 25/30500395 DC BS ISO 13084 Surface chemical analysis — Secondary ion mass spectrometry — Calibration of the mass scale for a time-of-flight secondary ion mass spectrometer
- 10/30199193 DC BS ISO 13084. Surface chemical analysis. Secondary ion mass spectrometry. Calibration of the mass scale for a time of flight secondary ion mass spectrometer
International Organization for Standardization (ISO)
- ISO 23830:2008 Surface chemical analysis - Secondary-ion mass spectrometry - Repeatability and constancy of the relative-intensity scale in static secondary-ion mass spectrometry
- ISO 13084:2018 Surface chemical analysis — Secondary ion mass spectrometry — Calibration of the mass scale for a time-of-flight secondary ion mass spectrometer
- ISO/TS 22933:2022 Surface chemical analysis — Secondary ion mass spectrometry — Method for the measurement of mass resolution in SIMS
- ISO 18114:2021 Surface chemical analysis - Secondary-ion mass spectrometry - Determination of relative sensitivity factors from ion-implanted reference materials
- ISO 18114:2003 Surface chemical analysis - Secondary-ion mass spectrometry - Determination of relative sensitivity factors from ion-implanted reference materials
- ISO 14911:1998 Water quality - Determination of dissolved Li<(hoch)+>, Na<(hoch)+>, NH<(Index)4><(hoch)+>, K<(hoch)+>, Mn<(hoch)2+>, Ca<(hoch)2+>, Mg<(hoch)2+>, Sr<(hoch)2+> and Ba<(hoch)2+> using ion chromatography - Method for water and waste water
- ISO 13084:2011 Surface chemical analysis - Secondary-ion mass spectrometry - Calibration of the mass scale for a time-of-flight secondary-ion mass spectrometer
Association Francaise de Normalisation
- NF X21-064*NF ISO 23830:2009 Surface chemical analysis - Secondary-ion mass spectrometry - Repeatability and constancy of the relative-intensity scale in static secondary-ion mass spectrometry.
- NF T90-048*NF EN ISO 14911:1999 Water quality - Determination of dissolved Li+, Na+, NH 4+, K+, Mn 2+, Ca 2+, Mg 2+, Sr 2+ and Ba 2+ using ion chromatography - Method for water and waste water.
Kingdom of Bahrain Testing and Metrology Directorate
- BH GSO ISO 13084:2016 Surface chemical analysis -- Secondary-ion mass spectrometry -- Calibration of the mass scale for a time-of-flight secondary-ion mass spectrometer
GCC Standardization Organization
- GSO ISO 13084:2013 Surface chemical analysis -- Secondary-ion mass spectrometry -- Calibration of the mass scale for a time-of-flight secondary-ion mass spectrometer
- GSO ISO 18114:2013 Surface chemical analysis -- Secondary-ion mass spectrometry -- Determination of relative sensitivity factors from ion-implanted reference materials
The Directorate General of Specifications and Metrology (DGSM)
- OS GSO ISO 13084:2013 Surface chemical analysis -- Secondary-ion mass spectrometry -- Calibration of the mass scale for a time-of-flight secondary-ion mass spectrometer
Korean Agency for Technology and Standards (KATS)
- KS D ISO 18114:2005 Surface chemical analysis-Secondary-ion mass spectrometry-Determination of relative sensitivity factors from ion-implanted reference materials
- KS I ISO 14911:2009 Water quality-Determination of dissolved Li+, Na+,NH4+, K+, Mn2+, Ca2+, Mg2+, Sr2+ and Ba2+ using ion chromatography-Method for water and waste water
Japanese Industrial Standards Committee (JISC)
- JIS K 0163:2010 Surface chemical analysis -- Secondary-ion mass spectrometry -- Determination of relative sensitivity factors from ion-implanted reference materials
- JIS K 0158:2021 Surface chemical analysis -- Secondary ion mass spectrometry -- Correction method for saturated intensity in single ion counting dynamic secondary ion mass spectrometry
- JIS K 0157:2021 Surface chemical analysis -- Secondary ion mass spectrometry -- Calibration of the mass scale for a time-of-flight secondary ion mass spectrometer
Swedish Institute for Standards
- SS-EN ISO 17294-2:2005 Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2: Determination of 62 elements (ISO 17294-2:2003)
German Institute for Standardization
- DIN EN ISO 14911:1999 Water quality - Determination of dissolved Li<(hoch)+>, Na<(hoch)+>, NH<(Index)4><(hoch)+>, K<(hoch)+>, Mn<(hoch)2+>, Ca<(hoch)2+>, Mg<(hoch)2+>, Sr<(hoch)2+> and Ba<(hoch)2+> using ion chromatography - Method for water and waste water (ISO 14911:1998); G
Standard Association of Australia (SAA)
- AS ISO 22048:2006 Surface chemical analysis - Information format for static secondary-ion mass spectrometry
- AS ISO 22048:2006(R2016) Surface chemical analysis - Information format for static secondary-ion mass spectrometry
- AS ISO 18114:2006 Surface chemical analysis - Secondary-ion mass spectrometry - Determination of relative sensitivity factors from ion-implanted reference materials
- AS ISO 18114:2006(R2016) Surface chemical analysis - Secondary-ion mass spectrometry - Determination of relative sensitivity factors from ion-implanted reference materials
European Committee for Standardization (CEN)
- EN ISO 14911:1999 Water Quality - Determination of Dissolved Li+, Na+, NH4+, K+, Mn2+, Ca2+, Mg2+, Sr2+ and Ba2+ Using Ion Chromatography - Method for Water and Waste Water ISO 14911:1998
Ente Nazionale Italiano di Unificazione
- UNI EN ISO 15061:2001 Water quality - Determination of dissolved bromate - Method by liquid chromatography of ions
ion trap mass spectrometry,ion trap MS,quadruple ion trap mass spectrometry,ion trap mass spectrometry mass spectrometry,Ion trap mass spectrometry + ion,Linear Ion Trap Mass Spectrometry,Ion Trap Mass Spec+,Linear Ion Trap Mass Spectrometry,Quadrupole Ion Trap Mass Spectrometry,Ion trap mass spectrometry (,ion trap mass spectrometry,Ion trap mass spec + peak,miniature ion trap mass spectrometry,ion trap MS,mass spec ion trap,Mass Spec + Ion Trap,Ion Trap and Mass Spectrometry,ion trap in mass spectrometer,mass spec ion trap