DC circuit breaker for photovoltaic system
DC circuit breaker for photovoltaic system, Total:142 items.
The international standard classification for "DC circuit breaker for photovoltaic system" includes: Switches , Solar energy engineering , Fuses and other overcurrent protection devices .
The Chinese standard classification for "DC circuit breaker for photovoltaic system" includes: Low-voltage distribution electrical equipment , Solar energy , High voltage switchgear , Electric power testing technique .
中华人民共和国国家质量监督检验检疫总局、中国国家标准化管理委员会
- GB/T 34581-2017 General technical requirements for photovoltaic system DC circuit breakers
- GB/T 33765-2017 DC connector for terrestrial photovoltaic systems
- GB/T 10963.2-2008 Circuit-breakers for overcurrent protection for household and similar installation―Part 2:Circuit-breakers for a.c.and d.c.operation
Group Standards of the People's Republic of China
- T/CEC 289-2019 General Technical Requirements for 10kV DC Circuit Breakers
- T/CEEIA 640-2022 DC side copper-aluminum connector for photovoltaic systems
- T/ZZB 2751-2022 DC connector for terrestrial photovoltaic systems
- T/ZZB 2713-2022 Permanent magnet DC motor used for solar tracking system
Hebei Provincial Standard of the People's Republic of China
- DB13/T 2254-2015 Photovoltaic independent DC system
工业和信息化部
- YD/T 3693-2020 DC circuit breaker for 240V/336V DC power supply system
国家市场监督管理总局、中国国家标准化管理委员会
- GB/T 39750-2021 Technology requirements of DC arc-fault circuit protection for photovoltaic power system
- GB/T 38328-2019 Common specifications of high-voltage direct current circuit-breakers for high-voltage direct current transmission using voltage sourced converters (VSC-HVDC)
国家能源局
- NB/T 10647-2021 Technical specification for DC circuit breakers of DC transmission systems integrating offshore wind farms
- NB/T 42107-2017 High-voltage direct current circuit-breaker
- NB/T 32045-2018 Code for Design of DC Generation System for Photovoltaic Power Stations
未注明发布机构
- CSA C22.2 No.330-2017 Photovoltaic rapid shutdown systems
- AS/NZS 62852:2020 Connectors for DC-application in photovoltaic systems — Safety requirements and tests (IEC 62852:2014, MOD)
- CSA C22.2 No.330-2023 Photovoltaic rapid shutdown systems
Professional Standard - Electricity
- DL/T 352-2010 Guide for maintenance of DC breaker
- DL/T 352-2019 Guidelines for maintenance of HVDC switches
- DL/T 352-2019(英文版) DC circuit breaker maintenance guide
- DL/T 1397.4-2014 General specification for DC power system test equipments of electric power system-Part 4: Testing system of DC circuit breaker operating characteristics
Military Standard of the People's Republic of China-General Armament Department
- GJB 354A-1999 General specifications for marine DC (high current) air circuit breakers
- GJB 354B-2021 General specifications for marine DC (high current) air circuit breakers
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
- GB/T 10963.3-2016 Circuit-breakers for overcurrent protection for household and similar installation―Part 3:Circuit-breakers for d.c.operation
- GB 10963.2-2008 Circuit-breakers for overcurrent protection for household and similar installation.Part 2:Circuit-breakers for a.c. and d.c. operation
- GB 10963.2-2003 Circuit-breakers for overcurrent protection for household and similar installation―Part 2:Circuit-breakers for a.c.and d.c.operation
Association Francaise de Normalisation
- NF EN IEC 63027:2023 Systèmes photovoltaïques - Détection et interruption d'arc en courant continu
- NF EN 62852:2015 Connectors for DC applications for photovoltaic systems - Safety requirements and testing
- NF EN 62852/A1:2020 Connectors for DC applications for photovoltaic systems - Safety requirements and testing
- NF C57-352*NF EN 62852:2015 Connectors for DC-application in photovoltaic systems - Safety requirements and tests
- NF C57-352/A1*NF EN 62852/A1:2020 Connectors for DC-application in photovoltaic systems - Safety requirements and tests
- NF F41-020-3:1998 D.C. Switchgear. Part 3 : indoor D.C. Disconnectors and switch-disconnectors.
- NF F41-022:1990 Railway fixed equipment. Circuit-breakers for direct current traction systems 600 and 750 V. Characteristics and tests.
ES-UNE
- EN IEC 63027:2023 Photovoltaic power systems - DC arc detection and interruption
- UNE-EN IEC 63027:2024 Photovoltaic power systems - DC arc detection and interruption
- UNE-EN 62852:2015/A1:2020 Connectors for DC-application in photovoltaic systems - Safety requirements and tests
- UNE-EN 62852:2015 Connectors for DC-application in photovoltaic systems - Safety requirements and tests
- UNE-EN 62852:2015/AC:2019-02 Connectors for DC-application in photovoltaic systems - Safety requirements and tests
British Standards Institution (BSI)
- BS EN IEC 63027:2023 Photovoltaic power systems. DC arc detection and interruption
- PD IEC TR 63225:2019 Incompatibility of connectors for DC-application in photovoltaic systems
- 17/30355420 DC BS IEC 63027. DC arc detection and interruption in photovoltaic power systems
- BS IEC 62852:2014 Connectors for DC-application in photovoltaic systems. Safety requirements and tests
- BS EN 62852:2015+A1:2020 Connectors for DC-application in photovoltaic systems. Safety requirements and tests
- 18/30367739 DC BS EN 62852 AMD 1. Connectors for DC-application in photovoltaic systems. Safety requirements and tests
- BS IEC 60898-3:2019+A1:2022 Electrical accessories. Circuit-breakers for overcurrent protection for household and similar installations - Circuit-breakers for DC operation
- BS EN 60898-2:2006 Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations - Circuit-breakers for a.c and d.c. operation
- 23/30451686 DC BS EN IEC 62852 AMD 2. Connectors for DC-application in photovoltaic systems. Safety requirements and tests
International Electrotechnical Commission (IEC)
- IEC 63027:2023 Photovoltaic power systems - DC arc detection and interruption
- IEC TR 63225:2019 Incompatibility of connectors for DC-application in photovoltaic systems
- IEC 62852:2014+AMD1:2020 CSV Connectors for DC-application in photovoltaic systems - Safety requirements and tests
- IEC 62852:2014/AMD1:2020 Connectors for DC-application in photovoltaic systems - Safety requirements and tests
- IEC 62852:2014 Connectors for DC-application in photovoltaic systems - Safety requirements and tests
- IEC 60898-2:2000+AMD1:2003 CSV Circuit-breakers for overcurrent protection for household and similar installations - Part 2: Circuit-breakers for a.c. and d.c. operation
SCC
- CEI EN IEC 63027:2023 Photovoltaic power systems DC arc detection and interruption
- DANSK DS/EN IEC 63027:2023 Photovoltaic power systems – DC arc detection and interruption
- CSA C22.2 No.305-2016 Molded-case circuit breakers, molded-case switches, and circuit-breaker enclosures for use with photovoltaic (PV) systems
- DIN EN IEC 63027:2024 Photovoltaic power systems - DC arc detection and interruption (IEC 63027:2023); German version EN IEC 63027:2023
- DANSK DS/IEC TR 63225:2019 Incompatibility of connectors for DC-application in photovoltaic systems
- BS PD IEC TR 63225:2019 Incompatibility of connectors for DC-application in photovoltaic systems
- AS C411:1970 Moulded-case circuit-breakers (up to and including 600 volts a.c. and 250 volts d.c.) interrupting rating 10 kA and more)
- CEI EN 62852/A1:2015 Connectors for DC-application in photovoltaic systems - Safety requirements and tests
- CEI EN 62852:2015 Connectors for DC-application in photovoltaic systems - Safety requirements and tests
- AENOR UNE-EN 62852:2015 Connectors for DC-application in photovoltaic systems - Safety requirements and tests
- DANSK DS/EN 62852:2015 Connectors for DC-application in photovoltaic systems - Safety requirements and tests
- BS 4752:1971 Specification for circuit breakes of rated voltage up to and including 1000 volts a.c and 1200 volts d.c
- BS 3871-2:1966 Moulded case circuit-breakers for a.c. and d.c. circuits
- BS 936:1940 Oil circuit-breakers for alternating-current circuits up to and including 660 volts
- AS C89:1967 Oil circuit-breakers for alternating current systems
- BS EN 62852:2015 Connectors for DC-application in photovoltaic systems. Safety requirements and tests
- DIN IEC /TR 63225:2021 Incompatibility of connectors for DC-application in photovoltaic systems (IEC TR 63225:2019)
- IEC 62852:2020 Connectors for DC-application in photovoltaic systems - Safety requirements and tests CONSOLIDATED EDITION
- AS C410:1970 Circuit-breakers for distribution circuits (up to and including 1000 volts a.c. and 1200 volts d.c.) (current ratings 63 amperes and above)
- CSA C22.2 No.330-2017(R2022) Photovoltaic rapid shutdown systems
- DIN EN 63027 E:2018 Draft Document - DC arc detection and interruption in photovoltaic power systems (IEC 82/1318/CD:2017)
- AS C380:1967 Heavy-duty air-break circuit-breakers for A.C. systems
- BS 116:1952 Oil circuit-breakers for alternating current systems above 1 kV
- BS EN 60898-2:2001 Circuit-breakers for overcurrent protection for household and similar installations-Circuit-breakers for a.c. and d.c. operation
Institute of Electrical and Electronics Engineers (IEEE)
- IEEE Std C37.17-1997 American National Standard for Trip Devices for AC and General Purpose DC Low Voltage Power Circuit Breakers
- IEEE Std C37.17-2012 Trip Systems for Low-Voltage (1000 V and below) AC and General Purpose (1500 V and below) DC Power Circuit Breakers
GSO
- GSO IEC TR 63225:2024 Incompatibility of connectors for DC-application in photovoltaic systems
- GSO IEC 62852:2021 Connectors for DC-application in photovoltaic systems - Safety requirements and tests
- BH GSO IEC 62852:2022 Connectors for DC-application in photovoltaic systems - Safety requirements and tests
- GSO IEC 60898-2:2010 Circuit-breakers for overcurrent protection for household and similar installations - Part 2: Circuit-breakers for a.c. and d.c. operation
Korean Agency for Technology and Standards (KATS)
- KS C IEC 62852-2016(2021) Connectors for DC-application in photovoltaic systems ― Safety requirements and tests
- KS C IEC 62852-2021 Connectors for DC-application in photovoltaic systems ― Safety requirements and tests
- KS C IEC 62852:2016 Connectors for DC-application in photovoltaic systems ― Safety requirements and tests
VDE - VDE Verlag GmbH@ Berlin@ Germany
- VDE V 0642-100-2018 Geraeteschutzschalter (GS) - Teil 100: Einrichtung zur Herstellung eines kontrollierten Kurzschlusses im DC-Bereich von PV-Anlagen
- VDE 0642-100-2016 Geraeteschutzschalter (GS) - Teil 100: Einrichtung zur Herstellung eines kontrollierten Kurzschlusses im DC-Bereich von PV-Anlagen
- VDE 0126-27-2018 DC arc detection and interruption in photovoltaic power systems (IEC 82/1318/CD:2017)
- VDE 0126-300-2015 Connectors for DC-application in photovoltaic systems - Safety requirements and tests (IEC 62852:2014); German version EN 62852:2015
- VDE 0115-300-4-2003 Railway applications - Fixed installations; D.C. switchgear - Part 4: Outdoor d.c. switch-disconnectors@ switch-disconnectors and earthing switches; German version EN 50123-4:2003
Underwriters Laboratories (UL)
- UL SUBJECT 489G-2016 Outline of Investigation for Molded-Case Circuit Breakers@ Molded-Case Switches@ and Circuit-Breaker Enclosures@ 650 – 1000 Volts AC and 650 – 1500 Volts DC (Issue 1)
- UL 489B-2021 UL Standard for Safety Molded-Case Circuit Breakers Molded-Case Switches and Circuit-Breaker Enclosures for Use with Photovoltaic (PV) Systems
- UL SUBJECT 489B-2013 Outline of Investigation for Molded-Case Circuit Breakers@ Molded-Case Switches@ and Circuit-Breaker Enclosures for Use with Photovoltaic (PV) Systems (Issue 3)
- UL SUBJECT 489B-2010 OUTLINE OF INVESTIGATION FOR MOLDED-CASE CIRCUIT BREAKERS@ MOLDED-CASE SWITCHES@ AND CIRCUIT-BREAKER ENCLOSURES FOR USE WITH PHOTOVOLTAIC (PV) SYSTEMS (Issue No. 1)
- UL SUBJECT 489B-2012 OUTLINE OF INVESTIGATION FOR MOLDED-CASE CIRCUIT BREAKERS@ MOLDED-CASE SWITCHES@ AND CIRCUIT-BREAKER ENCLOSURES FOR USE WITH PHOTOVOLTAIC (PV) SYSTEMS (Issue 2)
- UL SUBJECT 489B-2014 UL Outline of Investigation for Molded-Case Circuit Breakers@ Molded-Case Switches@ and Circuit-Breaker Enclosures for Use with Photovoltaic (PV) Systems (Issue 4)
- UL 489B-2016 UL Standard for Safety Molded-Case Circuit Breakers@ Molded-Case Switches@ and Circuit-Breaker Enclosures for Use with Photovoltaic (PV) Systems (First Edition)
- UL SUBJECT 2579-2011 OUTLINE OF INVESTIGATION FOR LOW-VOLTAGE FUSES – FUSES FOR PHOTOVOLTAIC SYSTEMS (Issue 8)
PL-PKN
- PN-EN 62852-2015-05/A1-2020-12 E Connectors for DC-application in photovoltaic systems - Safety requirements and tests
German Institute for Standardization
- DIN IEC/TR 63225:2021 Incompatibility of connectors for DC-application in photovoltaic systems (IEC TR 63225:2019)
- DIN EN 60898-2:2007 Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations - Part 2: Circuit-breakers for a.c. and d.c. operation (IEC 60898-2:2000 + A1:2003, modified); German version EN 60898-2:2006
European Committee for Electrotechnical Standardization(CENELEC)
- EN 62852:2015 Connectors for DC-application in photovoltaic systems - Safety requirements and tests
GOSTR
- GOST R 57230-2016 Photovoltaic systems. Connectors for DC-application. Classification, requirements and test methods
Japanese Industrial Standards Committee (JISC)
- JIS E 4901:1991 DC fuses for railway rolling stock
- JIS C 62852:2020 Connectors for DC-application in photovoltaic systems -- Safety requirements and tests
RO-ASRO
- STAS 5414-1983 ROTAR Y SWITCHES AND CIRCUIT BREAKERS UP TO 100 A AND 660 V a.c. AND 440 V d.c. Special technical requirements
DIN
- DIN EN 62852:2015 Connectors for DC-application in photovoltaic systems - Safety requirements and tests (IEC 62852:2014); German version EN 62852:2015
AT-OVE/ON
- OVE EN 62852-2021 Connectors for DC-application in photovoltaic systems - Safety requirements and tests (german version)
Defense Logistics Agency
- DLA A-A-55571/4 E-2009 CIRCUIT BREAKER, 28 VOLTS (V) DC, MANUAL RESET, WATERPROOF, 35 AMPERES (A) TO 150 A
- DLA A-A-55571/1 D-2008 CIRCUIT BREAKER, 28 VOLTS (V) DC, AUTOMATIC RESET, WATERPROOF, 15 AMPERES (A) TO 30 A
- DLA A-A-55571/2 E-2009 CIRCUIT BREAKER, 28 VOLTS (V) DC, MANUAL RESET, WATERPROOF, 15 AMPERES (A) TO 30 A
- DLA SMD-5962-06221-2008 MICROCIRCUIT, HYBRID, 5 VOLT SINGLE CHANNEL, DC-DC CONVERTER
- DLA A-A-55571/3 D-2008 CIRCUIT BREAKER, 28 VOLTS (V) DC, MANUAL RESET, WATERPROOF, 105 AMPERES (A) TO 200 A
- DLA A-A-55571/3 E-2009 CIRCUIT BREAKER, 28 VOLTS (V) DC, MANUAL RESET, WATERPROOF, 105 AMPERES (A) TO 200 A
- DLA A-A-55571/2 D-2008 CIRCUIT BREAKER, 28 VOLTS (V) DC, MANUAL RESET, WATERPROOF, 15 AMPERES (A) TO 30 A
- DLA A-A-55571/1 E-2009 CIRCUIT BREAKER, 28 VOLTS (V) DC, AUTOMATIC RESET, WATERPROOF, 15 AMPERES (A) TO 30 A
- DLA SMD-5962-06220-2008 MICROCIRCUIT, HYBRID, 3.3 VOLT SINGLE CHANNEL, DC-DC CONVERTER
- DLA SMD-5962-06222-2008 MICROCIRCUIT, HYBRID, 15 VOLT SINGLE CHANNEL, DC-DC CONVERTER
- DLA A-A-55571/8 E-2009 CIRCUIT BREAKER, 28 VOLTS (V) DC, AUTOMATIC RESET, NONWATERPROOF, 150 AMPERES (A) TO 200 A
- DLA A-A-55571/5 D-2008 CIRCUIT BREAKER, 28 VOLTS (V) DC, AUTOMATIC RESET, NONWATERPROOF, 10 AMPERES (A) TO 35 A
- DLA A-A-55571/6 E-2009 CIRCUIT BREAKER, 28 VOLTS (V) DC, MANUAL RESET, NONWATERPROOF, 10 AMPERES (A) TO 35 A
- DLA SMD-5962-04242-2006 MICROCIRCUIT, HYBRID, 5 VOLT, DUAL CHANNEL, DC/DC CONVERTER
- DLA SMD-5962-04244-2006 MICROCIRCUIT, HYBRID, 15 VOLT, DUAL CHANNEL, DC/DC CONVERTER
- DLA SMD-5962-04240-2006 MICROCIRCUIT, HYBRID, 12 VOLT, SINGLE CHANNEL, DC/DC CONVERTER
- DLA SMD-5962-05239-2006 MICROCIRCUIT, HYBRID, 3.3 VOLT, SINGLE CHANNEL, DC/DC CONVERTER
- DLA A-A-55571/5 E-2009 CIRCUIT BREAKER, 28 VOLTS (V) DC, AUTOMATIC RESET, NONWATERPROOF, 10 AMPERES (A) TO 35 A
- DLA SMD-5962-04238-2006 MICROCIRCUIT, HYBRID, 3.3 VOLT, SINGLE CHANNEL, DC/DC CONVERTER
- DLA SMD-5962-04248-2006 MICROCIRCUIT, HYBRID, 12 VOLT, SINGLE CHANNEL, DC/DC CONVERTER
- DLA A-A-55571/6 D-2008 CIRCUIT BREAKER, 28 VOLTS (V) DC, MANUAL RESET, NONWATERPROOF, 10 AMPERES (A) TO 35 A
- DLA A-A-55571/7 E-2009 CIRCUIT BREAKER, 28 VOLTS (V) DC, AUTOMATIC RESET, NONWATERPROOF, 35 AMPERES (A) TO 150 A
- DLA A-A-55571/8 D-2008 CIRCUIT BREAKER, 28 VOLTS (V) DC, AUTOMATIC RESET, NONWATERPROOF, 150 AMPERES (A) TO 200 A
American National Standards Institute (ANSI)
- ANSI/IEEE C37.14:2002 Low-Voltage DC Power Circuit Breakers Used in Enclosures
JP-JARI
- JRIS E 4901-2004 DC fuses for railway rolling stock
SE-SIS
- SIS SS 424 14 02-1991 Wiring systems for max 1000 V — Methods of calculation to safeguard correct disconnection — Directly earthed systems protected by circuit-breakers
- SIS SS 424 14 03-1991 Wiring systems for max 1000 V — Methods of calculation to safeguard correct disconnection — Not directly earthed systems protected by circuit-breakers
United States Navy
- NAVY QPL-17588-26-1994 CIRCUIT BREAKERS (AUTOMATIC - ALB-1) AND SWITCH, TOGGLE (CIRCUIT BREAKER, NON-AUTOMATIC - NLB-1) AIR, INSULATED HOUSING, 125 VOLTS AND BELOW, A.C. AND D.C., (NAVAL SHIPBOARD USE)
CN-QIYE
- Q/GDW 1901.4-2013 General technical conditions for test equipment for electric power DC power systems Part 4: DC circuit breaker operating characteristics test system
- Q/GDW 1901.4―2013 General technical requirements for test equipment for electric DC power supply systems Part 4: Test system for operating characteristics of DC circuit breakers
Standard Association of Australia (SAA)
- AS/NZS 62852:2023 Connectors for DC-application in photovoltaic systems — Safety requirements and tests (IEC 62852:2014 (ED. 1.1) MOD)
Military Standards (MIL-STD)
- DOD MIL-C-17588E (5)-1993 CIRCUIT BREAKERS (AUTOMATIC - ALB-1) AND SWITCH, TOGGLE (CIRCUIT BREAKER, NON-AUTOMATIC - NLB-1) AIR, INSULATED HOUSING, 125 VOLTS AND BELOW, A.C. AND D.C., (NAVAL SHIPBOARD USE)
RU-GOST R
- GOST IEC 60898-2-2011 Circuit-breakers for overcurrent protection for household and similar installations. Part 2. Circuit-breakers for a.c. and d.c. operation
General technical requirements for DC circuit breakers for photovoltaic systems,DC circuit breaker for photovoltaic system