Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)

DC circuit breaker for photovoltaic system

DC circuit breaker for photovoltaic system, Total:142 items.

The international standard classification for "DC circuit breaker for photovoltaic system" includes: Switches , Solar energy engineering , Fuses and other overcurrent protection devices .

The Chinese standard classification for "DC circuit breaker for photovoltaic system" includes: Low-voltage distribution electrical equipment , Solar energy , High voltage switchgear , Electric power testing technique .


中华人民共和国国家质量监督检验检疫总局、中国国家标准化管理委员会

  • GB/T 34581-2017 General technical requirements for photovoltaic system DC circuit breakers
  • GB/T 33765-2017 DC connector for terrestrial photovoltaic systems
  • GB/T 10963.2-2008 Circuit-breakers for overcurrent protection for household and similar installation―Part 2:Circuit-breakers for a.c.and d.c.operation

Group Standards of the People's Republic of China

Hebei Provincial Standard of the People's Republic of China

工业和信息化部

  • YD/T 3693-2020 DC circuit breaker for 240V/336V DC power supply system

国家市场监督管理总局、中国国家标准化管理委员会

  • GB/T 39750-2021 Technology requirements of DC arc-fault circuit protection for photovoltaic power system
  • GB/T 38328-2019 Common specifications of high-voltage direct current circuit-breakers for high-voltage direct current transmission using voltage sourced converters (VSC-HVDC)

国家能源局

  • NB/T 10647-2021 Technical specification for DC circuit breakers of DC transmission systems integrating offshore wind farms
  • NB/T 42107-2017 High-voltage direct current circuit-breaker
  • NB/T 32045-2018 Code for Design of DC Generation System for Photovoltaic Power Stations

未注明发布机构

Professional Standard - Electricity

  • DL/T 352-2010 Guide for maintenance of DC breaker
  • DL/T 352-2019 Guidelines for maintenance of HVDC switches
  • DL/T 352-2019(英文版) DC circuit breaker maintenance guide
  • DL/T 1397.4-2014 General specification for DC power system test equipments of electric power system-Part 4: Testing system of DC circuit breaker operating characteristics

Military Standard of the People's Republic of China-General Armament Department

  • GJB 354A-1999 General specifications for marine DC (high current) air circuit breakers
  • GJB 354B-2021 General specifications for marine DC (high current) air circuit breakers

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China

  • GB/T 10963.3-2016 Circuit-breakers for overcurrent protection for household and similar installation―Part 3:Circuit-breakers for d.c.operation
  • GB 10963.2-2008 Circuit-breakers for overcurrent protection for household and similar installation.Part 2:Circuit-breakers for a.c. and d.c. operation
  • GB 10963.2-2003 Circuit-breakers for overcurrent protection for household and similar installation―Part 2:Circuit-breakers for a.c.and d.c.operation

Association Francaise de Normalisation

  • NF EN IEC 63027:2023 Systèmes photovoltaïques - Détection et interruption d'arc en courant continu
  • NF EN 62852:2015 Connectors for DC applications for photovoltaic systems - Safety requirements and testing
  • NF EN 62852/A1:2020 Connectors for DC applications for photovoltaic systems - Safety requirements and testing
  • NF C57-352*NF EN 62852:2015 Connectors for DC-application in photovoltaic systems - Safety requirements and tests
  • NF C57-352/A1*NF EN 62852/A1:2020 Connectors for DC-application in photovoltaic systems - Safety requirements and tests
  • NF F41-020-3:1998 D.C. Switchgear. Part 3 : indoor D.C. Disconnectors and switch-disconnectors.
  • NF F41-022:1990 Railway fixed equipment. Circuit-breakers for direct current traction systems 600 and 750 V. Characteristics and tests.

ES-UNE

British Standards Institution (BSI)

  • BS EN IEC 63027:2023 Photovoltaic power systems. DC arc detection and interruption
  • PD IEC TR 63225:2019 Incompatibility of connectors for DC-application in photovoltaic systems
  • 17/30355420 DC BS IEC 63027. DC arc detection and interruption in photovoltaic power systems
  • BS IEC 62852:2014 Connectors for DC-application in photovoltaic systems. Safety requirements and tests
  • BS EN 62852:2015+A1:2020 Connectors for DC-application in photovoltaic systems. Safety requirements and tests
  • 18/30367739 DC BS EN 62852 AMD 1. Connectors for DC-application in photovoltaic systems. Safety requirements and tests
  • BS IEC 60898-3:2019+A1:2022 Electrical accessories. Circuit-breakers for overcurrent protection for household and similar installations - Circuit-breakers for DC operation
  • BS EN 60898-2:2006 Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations - Circuit-breakers for a.c and d.c. operation
  • 23/30451686 DC BS EN IEC 62852 AMD 2. Connectors for DC-application in photovoltaic systems. Safety requirements and tests

International Electrotechnical Commission (IEC)

  • IEC 63027:2023 Photovoltaic power systems - DC arc detection and interruption
  • IEC TR 63225:2019 Incompatibility of connectors for DC-application in photovoltaic systems
  • IEC 62852:2014+AMD1:2020 CSV Connectors for DC-application in photovoltaic systems - Safety requirements and tests
  • IEC 62852:2014/AMD1:2020 Connectors for DC-application in photovoltaic systems - Safety requirements and tests
  • IEC 62852:2014 Connectors for DC-application in photovoltaic systems - Safety requirements and tests
  • IEC 60898-2:2000+AMD1:2003 CSV Circuit-breakers for overcurrent protection for household and similar installations - Part 2: Circuit-breakers for a.c. and d.c. operation

SCC

  • CEI EN IEC 63027:2023 Photovoltaic power systems DC arc detection and interruption
  • DANSK DS/EN IEC 63027:2023 Photovoltaic power systems – DC arc detection and interruption
  • CSA C22.2 No.305-2016 Molded-case circuit breakers, molded-case switches, and circuit-breaker enclosures for use with photovoltaic (PV) systems
  • DIN EN IEC 63027:2024 Photovoltaic power systems - DC arc detection and interruption (IEC 63027:2023); German version EN IEC 63027:2023
  • DANSK DS/IEC TR 63225:2019 Incompatibility of connectors for DC-application in photovoltaic systems
  • BS PD IEC TR 63225:2019 Incompatibility of connectors for DC-application in photovoltaic systems
  • AS C411:1970 Moulded-case circuit-breakers (up to and including 600 volts a.c. and 250 volts d.c.) interrupting rating 10 kA and more)
  • CEI EN 62852/A1:2015 Connectors for DC-application in photovoltaic systems - Safety requirements and tests
  • CEI EN 62852:2015 Connectors for DC-application in photovoltaic systems - Safety requirements and tests
  • AENOR UNE-EN 62852:2015 Connectors for DC-application in photovoltaic systems - Safety requirements and tests
  • DANSK DS/EN 62852:2015 Connectors for DC-application in photovoltaic systems - Safety requirements and tests
  • BS 4752:1971 Specification for circuit breakes of rated voltage up to and including 1000 volts a.c and 1200 volts d.c
  • BS 3871-2:1966 Moulded case circuit-breakers for a.c. and d.c. circuits
  • BS 936:1940 Oil circuit-breakers for alternating-current circuits up to and including 660 volts
  • AS C89:1967 Oil circuit-breakers for alternating current systems
  • BS EN 62852:2015 Connectors for DC-application in photovoltaic systems. Safety requirements and tests
  • DIN IEC /TR 63225:2021 Incompatibility of connectors for DC-application in photovoltaic systems (IEC TR 63225:2019)
  • IEC 62852:2020 Connectors for DC-application in photovoltaic systems - Safety requirements and tests CONSOLIDATED EDITION
  • AS C410:1970 Circuit-breakers for distribution circuits (up to and including 1000 volts a.c. and 1200 volts d.c.) (current ratings 63 amperes and above)
  • CSA C22.2 No.330-2017(R2022) Photovoltaic rapid shutdown systems
  • DIN EN 63027 E:2018 Draft Document - DC arc detection and interruption in photovoltaic power systems (IEC 82/1318/CD:2017)
  • AS C380:1967 Heavy-duty air-break circuit-breakers for A.C. systems
  • BS 116:1952 Oil circuit-breakers for alternating current systems above 1 kV
  • BS EN 60898-2:2001 Circuit-breakers for overcurrent protection for household and similar installations-Circuit-breakers for a.c. and d.c. operation

Institute of Electrical and Electronics Engineers (IEEE)

  • IEEE Std C37.17-1997 American National Standard for Trip Devices for AC and General Purpose DC Low Voltage Power Circuit Breakers
  • IEEE Std C37.17-2012 Trip Systems for Low-Voltage (1000 V and below) AC and General Purpose (1500 V and below) DC Power Circuit Breakers

GSO

  • GSO IEC TR 63225:2024 Incompatibility of connectors for DC-application in photovoltaic systems
  • GSO IEC 62852:2021 Connectors for DC-application in photovoltaic systems - Safety requirements and tests
  • BH GSO IEC 62852:2022 Connectors for DC-application in photovoltaic systems - Safety requirements and tests
  • GSO IEC 60898-2:2010 Circuit-breakers for overcurrent protection for household and similar installations - Part 2: Circuit-breakers for a.c. and d.c. operation

Korean Agency for Technology and Standards (KATS)

  • KS C IEC 62852-2016(2021) Connectors for DC-application in photovoltaic systems ― Safety requirements and tests
  • KS C IEC 62852-2021 Connectors for DC-application in photovoltaic systems ― Safety requirements and tests
  • KS C IEC 62852:2016 Connectors for DC-application in photovoltaic systems ― Safety requirements and tests

VDE - VDE Verlag GmbH@ Berlin@ Germany

  • VDE V 0642-100-2018 Geraeteschutzschalter (GS) - Teil 100: Einrichtung zur Herstellung eines kontrollierten Kurzschlusses im DC-Bereich von PV-Anlagen
  • VDE 0642-100-2016 Geraeteschutzschalter (GS) - Teil 100: Einrichtung zur Herstellung eines kontrollierten Kurzschlusses im DC-Bereich von PV-Anlagen
  • VDE 0126-27-2018 DC arc detection and interruption in photovoltaic power systems (IEC 82/1318/CD:2017)
  • VDE 0126-300-2015 Connectors for DC-application in photovoltaic systems - Safety requirements and tests (IEC 62852:2014); German version EN 62852:2015
  • VDE 0115-300-4-2003 Railway applications - Fixed installations; D.C. switchgear - Part 4: Outdoor d.c. switch-disconnectors@ switch-disconnectors and earthing switches; German version EN 50123-4:2003

Underwriters Laboratories (UL)

  • UL SUBJECT 489G-2016 Outline of Investigation for Molded-Case Circuit Breakers@ Molded-Case Switches@ and Circuit-Breaker Enclosures@ 650 – 1000 Volts AC and 650 – 1500 Volts DC (Issue 1)
  • UL 489B-2021 UL Standard for Safety Molded-Case Circuit Breakers Molded-Case Switches and Circuit-Breaker Enclosures for Use with Photovoltaic (PV) Systems
  • UL SUBJECT 489B-2013 Outline of Investigation for Molded-Case Circuit Breakers@ Molded-Case Switches@ and Circuit-Breaker Enclosures for Use with Photovoltaic (PV) Systems (Issue 3)
  • UL SUBJECT 489B-2010 OUTLINE OF INVESTIGATION FOR MOLDED-CASE CIRCUIT BREAKERS@ MOLDED-CASE SWITCHES@ AND CIRCUIT-BREAKER ENCLOSURES FOR USE WITH PHOTOVOLTAIC (PV) SYSTEMS (Issue No. 1)
  • UL SUBJECT 489B-2012 OUTLINE OF INVESTIGATION FOR MOLDED-CASE CIRCUIT BREAKERS@ MOLDED-CASE SWITCHES@ AND CIRCUIT-BREAKER ENCLOSURES FOR USE WITH PHOTOVOLTAIC (PV) SYSTEMS (Issue 2)
  • UL SUBJECT 489B-2014 UL Outline of Investigation for Molded-Case Circuit Breakers@ Molded-Case Switches@ and Circuit-Breaker Enclosures for Use with Photovoltaic (PV) Systems (Issue 4)
  • UL 489B-2016 UL Standard for Safety Molded-Case Circuit Breakers@ Molded-Case Switches@ and Circuit-Breaker Enclosures for Use with Photovoltaic (PV) Systems (First Edition)
  • UL SUBJECT 2579-2011 OUTLINE OF INVESTIGATION FOR LOW-VOLTAGE FUSES – FUSES FOR PHOTOVOLTAIC SYSTEMS (Issue 8)

PL-PKN

German Institute for Standardization

  • DIN IEC/TR 63225:2021 Incompatibility of connectors for DC-application in photovoltaic systems (IEC TR 63225:2019)
  • DIN EN 60898-2:2007 Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations - Part 2: Circuit-breakers for a.c. and d.c. operation (IEC 60898-2:2000 + A1:2003, modified); German version EN 60898-2:2006

European Committee for Electrotechnical Standardization(CENELEC)

  • EN 62852:2015 Connectors for DC-application in photovoltaic systems - Safety requirements and tests

GOSTR

  • GOST R 57230-2016 Photovoltaic systems. Connectors for DC-application. Classification, requirements and test methods

Japanese Industrial Standards Committee (JISC)

  • JIS E 4901:1991 DC fuses for railway rolling stock
  • JIS C 62852:2020 Connectors for DC-application in photovoltaic systems -- Safety requirements and tests

RO-ASRO

  • STAS 5414-1983 ROTAR Y SWITCHES AND CIRCUIT BREAKERS UP TO 100 A AND 660 V a.c. AND 440 V d.c. Special technical requirements

DIN

  • DIN EN 62852:2015 Connectors for DC-application in photovoltaic systems - Safety requirements and tests (IEC 62852:2014); German version EN 62852:2015

AT-OVE/ON

  • OVE EN 62852-2021 Connectors for DC-application in photovoltaic systems - Safety requirements and tests (german version)

Defense Logistics Agency

American National Standards Institute (ANSI)

JP-JARI

SE-SIS

  • SIS SS 424 14 02-1991 Wiring systems for max 1000 V — Methods of calculation to safeguard correct disconnection — Directly earthed systems protected by circuit-breakers
  • SIS SS 424 14 03-1991 Wiring systems for max 1000 V — Methods of calculation to safeguard correct disconnection — Not directly earthed systems protected by circuit-breakers

United States Navy

  • NAVY QPL-17588-26-1994 CIRCUIT BREAKERS (AUTOMATIC - ALB-1) AND SWITCH, TOGGLE (CIRCUIT BREAKER, NON-AUTOMATIC - NLB-1) AIR, INSULATED HOUSING, 125 VOLTS AND BELOW, A.C. AND D.C., (NAVAL SHIPBOARD USE)

CN-QIYE

  • Q/GDW 1901.4-2013 General technical conditions for test equipment for electric power DC power systems Part 4: DC circuit breaker operating characteristics test system
  • Q/GDW 1901.4―2013 General technical requirements for test equipment for electric DC power supply systems Part 4: Test system for operating characteristics of DC circuit breakers

Standard Association of Australia (SAA)

  • AS/NZS 62852:2023 Connectors for DC-application in photovoltaic systems — Safety requirements and tests (IEC 62852:2014 (ED. 1.1) MOD)

Military Standards (MIL-STD)

  • DOD MIL-C-17588E (5)-1993 CIRCUIT BREAKERS (AUTOMATIC - ALB-1) AND SWITCH, TOGGLE (CIRCUIT BREAKER, NON-AUTOMATIC - NLB-1) AIR, INSULATED HOUSING, 125 VOLTS AND BELOW, A.C. AND D.C., (NAVAL SHIPBOARD USE)

RU-GOST R

  • GOST IEC 60898-2-2011 Circuit-breakers for overcurrent protection for household and similar installations. Part 2. Circuit-breakers for a.c. and d.c. operation