Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
electrical error electrical error requirement electrical error detection pairsallowable electrical error level two-speed electrical resolvers introduction standard evolution ice rinks real-life scenery performance asynchronous terminals
GB/T 10404-2017 in English

GB/T 10404-2017 in English

VALID

General specification for multipolar and two-speed electrical resolvers

  • Issued on:2017-11-01
  • Implemented on:2018-05-01
  • File Format:PDF
  • Delivery:Via email within 5 business days
Price(USD): $550.00
$534.00
Standard No: GB/T 10404-2017
Document status: VALID
Title in English: General specification for multipolar and two-speed electrical resolvers
Title in Chinese: 多极和双通道旋转变压器通用技术条件
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 5 business days
Issued on: 2017-11-01
Implemented on: 2018-05-01
Superseding: GB/T 10404-2007 General specification for multipolar and two-speed electrical resolvers
ICS Classification: 29.160.30-Motors
Professional Classification: GB-National Standard
Related Keywords: electrical error
electrical error requirement
electrical error detection
pairsallowable electrical error level
two-speed electrical resolvers introduction standard evolution
Related Topics: multi-channel pressure
dual channel gas
Batch or multi-channel English
Multi-channel pressure gauge
double channel
multi-channel rotary
multi-electrode rotation
single and dual channel
dual channel use
dual channel injection
multi-channel counter
instrument single channel dual channel
Optical rotation conditions
GBT10404
GB/T 10404-1989
GB/T 10404-2007
GB/T 10404-2017
Special transformer technology for rail transit

《GB/T 10404-2017多极和双通道旋转变压器通用技术条件》由TC2(全国微电机标准化技术委员会)归口,主管部门为中国电器工业协会。


Introduction

Standard Evolution and Technology Update

This standard replaces GB/T 10404-2007. The main technical changes include:

  • Added a new parameter for rated voltage 6/2V combination
  • Clarified the criterion for determining the direction of rotation (from the perspective of the shaft extension end)
  • The electrical schematic diagram was changed to a circuit diagram and an output voltage equation
  • Added specific requirements for environmental tests such as vibration and salt spray

Core parameter system

Parameter TypeXFD/XFS TransmitterXBD/XBS Transformer
Rated Frequency (Hz)400/1000/2000
Pole pairs4-128 (16 specifications)
Rated voltage (V)36/26/612/6

Application case: 70-base XFS dual-channel resolver in CNC machine tools, when the precision machine pole pair number is 16P, the electrical error requirement is ≤15"


Accuracy classification system

Machine modelPole pairsAllowable electrical error
Level 0Level ILevel II
Precision machine≤84.5"1'30"3'
≥643"5"10"
Rough machine4-12820'-30'

Key technical requirements

Zero voltage: Rough machine ≤0.5% maximum output voltage, fine machine ≤0.3%

Insulation resistance: Normal temperature ≥50MΩ, high temperature ≥10MΩ, wet heat ≥1MΩ

Life test: 2000 hours (1150±50r/min)


Implementation suggestions

  1. Pay attention to the matching relationship between the number of pole pairs and the accuracy grade when selecting
  2. Ensure that the radial runout of the shaft extension is ≤0.02mm during installation
  3. A phase-sensitive voltmeter (input impedance>500kΩ) is required for electrical error detection