Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
power transformers power transformer load loss measurement three-winding transformers three-phase transformers auto-connected transformers metal pipe work air-blast sprayer-duster part spot gb/t
GB/T 13499-2002 in English

GB/T 13499-2002 in English

VALID

Power transformers--Application guide

  • Issued on:1992-06-02
  • Implemented on:2003-03-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $600.00
$582.00

《GB/T 13499-2002电力变压器应用导则》由TC44(全国变压器标准化技术委员会)归口,主管部门为中国电器工业协会。
本标准适用于符合GB l094系列标准和GB 6450等标准的电力变压器。本标准的目的是为用户提供如下信息:――不同的变压器联结和磁路设计的基本运行特性,特别是关于零序现象;――具有Ynynd和类似联结的变压器内的系统故障电流;――变压器的并联运行,负载条件下电压降或电压升的计算方法,以及三绕组负载组合下的负载损耗计算方法;――定货时,如何根据预期的负载条件选择额定参数和分接参数;――按常规设计的变压器,如何适用于变流负载;――有关损耗测量的测量技术和准确度。本标准中有一部分内容具有通用性的性质并适用于各种容量的电力变压器。然而,有几章仅涉及大型高压变压器的规范和应用问题。本标准所述的一些建议不具有强制性,因而,它不是规范要求。关于电力变压器负载能力的信息,对于油浸式变压器,见GB/T 15164;对于干式变压器,见GB/T 17211。有关电力变压器冲击试验的导则,见GB/T 7449。


1 General

1.1 Scope and object
This Standard applies to power transformers complying with the series of GB 1094 and GB 6450, etc.
It is intended to provide information to users about:
— Certain fundamental service characteristics of different transformer connections and magnetic circuit designs, with particular reference to zero-sequence phenomena;
— System fault currents in transformers with YNynd and similar connections;
— Parallel operation of transformers, calculation of voltage drop or rise under load, and calculation of load loss for three-winding load combinations;
— Selection of rated quantities and tapping quantities at the time of purchase, based on prospective loading cases;
— Application of transformers of conventional design to convertor loading;
— Measuring technique and accuracy in loss measurement.
Part of the information is of a general nature and applicable to all sizes of power transformers.
Several chapters, however, deal with aspects and problems which are of the interest only for the specification and utilization of large high-voltage units.
The recommendations are not mandatory and do not in themselves constitute specification requirements.
Information concerning loadability of power transformers is given in GB/T 15164, for oil-immersed transformers, and GB/T 17211, for dry-type transformers.
Guidance for impulse testing of power transformers is given in GB/T 7449.

1.2 Normative references
The following normative documents contain provisions which, through reference in this text, constitute provisions of this Standard. At the time of publication, the editions indicated were valid. All normative documents are subject to revision, and parties to agreements based on this Standard are encouraged to investigate the possibility of applying the most recent edition of the normative documents indicated below.

Contents
1 General
1.1 Scope and object
1.2 Normative references
2 Characteristic Properties of Different Three-phase Winding Combinations and Magnetic Circuit Designs
2.1 Y-, D-, and Z-connected windings
2.2 Characteristic properties of combinations of winding connections
2.3 Different magnetic circuit designs
3 Characteristic Properties and Application of Auto-connected Transformers
3.1 By definition, an auto-connected transformer is a transformer in which at least two windings have a common part (see 3.1.2 of GB 1094.1-1996).
3.2 The reduction factor or auto-factor, α
3.3 Short-circuit Impedance and Leakage Flux Effects
3.4 System restrictions, insulation co-ordination
3.5 Voltage regulation in system-interconnection autotransformers
4 Zero-sequence Properties — Neutral Load Current and Earth Fault Conditions, Magnetic Saturation and Inrush Current
4.1 Introduction of the symmetrical components of a three-phase system
4.2 Impedance parameters for symmetrical components
4.3 Single-line equivalent diagram of the transformer for zero-sequence phenomena
4.4 Magnetizing impedance under asymmetrical conditions — zero-sequence voltage and magnetic circuit geometry
4.5 Zero-sequence and delta windings
4.6 Zero-sequence and zigzag windings
4.7 Zero-sequence impedance properties of different transformer connections
4.8 Continuous zero-sequence loading (neutral point current)
4.9 Magnetic circuit reluctance and magnetizing impedance, steady-state saturation under abnormally high power frequency voltage
4.10 Transient saturation, inrush current
4.11 Geomagnetically induced current and parasitic currents from d.c. systems
5 Calculation of Short-circuit Currents in Three-winding, Three-phase Transformers (Separate Winding Transformers and Auto-connected Transformers) with Earthed Neutrals
5.1 General
5.2 Notations of systems and windings
5.3 Transformer parameters
5.4 Impedances of systems I and II
5.5 Summary of cases studied in this subclause
6 Parallel Operation of Transformers in Three-phase Systems
6.1 Matching three-phase connections and phase-angle relations
6.2 Difference in ratio, circulating current
6.3 Unequal short-circuit impedances
6.4 Variation of short-circuit impedance across the tapping range, influence of winding arrangement
7 Calculation of Voltage Drop for a Specified Load, Three-winding Transformer Load Loss
7.1 Introduction: the need for voltage drop calculation
7.2 The short-circuit impedance and equivalent diagram of a two-winding transformer
7.3 Description of the load
7.4 The voltage drop equations
7.5 Voltage drop calculation in per cent notation
7.6 Equivalent diagram for multi-winding transformers, T-equivalent impedance elements for a three-winding transformer
7.7 Allocation of load losses to individual windings in three-winding transformers
7.8 Example of calculation of voltage drop and load loss for a three-winding transformer
7.9 Example of calculation of combined load loss and allocation of losses to individual windings in an auto-connected three-winding transformer
8 Specification of Rated Quantities and Tapping Quantities
8.1 Introduction
8.2 Standardized specifications of ratings and tappings, effect of the width of the tapping range
8.3 Procedure for the determination of rated and tapping quantities
8.4 Details of the procedure, step by step
9 Convertor Applications with Standard Transformers
9.1 Influence of distorted voltage
9.2 Influence of distorted current, general
9.3 Overall eddy losses in windings
9.4 Stray losses in mechanical parts
9.5 Combined additional loss, possible de-rating
9.6 Local hotspots
10 Guide to the Measurement of Losses in Power Transformers
10.1 Test results, guarantees, tolerances, uncertainty limits
10.2 Traceability, quality aspects on measuring technique
10.3 Fundamental sources of error in power transformer load loss measurement
10.4 Phase angle error of a conventional loss measuring system, possibility of correction
10.5 Advanced measuring systems
10.6 Measurement of no-load loss
Appendix A (Informative) Basic Relations for Single-phase and Two-phase Earth Faults