Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
overhead power lines overhead power lines scopethis standard low voltage power lines strain insulators tension insulators cashmere blanket introductionthis standard multi-level radiation protection system engineering comparison internal thread grinder technical conditions scopethis standard
GB/T 1386.2-1997 in English

GB/T 1386.2-1997 in English

SUPERSEDED

Insulators for low voltage power lines--Part 2: Strain insulators for overhead power lines

  • Issued on:1997-04-01
  • Implemented on:1998-04-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $100.00
$97.00
Standard No: GB/T 1386.2-1997
Document status: SUPERSEDED
Superseded by: JB/T 10585.2-2006 Insulators for low voltage power lines Part 2: Strain insulators for overhead power lines
Superseded on: 2007-09-29
Title in English: Insulators for low voltage power lines--Part 2: Strain insulators for overhead power lines
Title in Chinese: 低压电力线路绝缘子 第2部分:架空电力线路用拉紧绝缘子
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 1997-04-01
Implemented on: 1998-04-01
Superseding: GB 1387-1978 Stay insulators for overhead power lines
ICS Classification: 29.080.10-Insulators
Chinese Classification: K48-Insulator
Professional Classification: GB-National Standard
Related Keywords: overhead power lines
overhead power lines scopethis standard
low voltage power lines
strain insulators
tension insulators
Related Topics: High Voltage Insulated Circuit
Electronic tension meter
circuit insulator
GBT1386.2
power line
Mylar insulation sheet
Coagulation line insulation testing
Technical requirements for low voltage SM insulators
Terminal crimping tension standard
Crimp terminal pulling force standard
Low voltage circuit insulation testing
Power battery insulation withstand voltage test
Electronic product terminal block pull test
Low Voltage Insulators International
gold wire tension
Insulator shear force test
Electronic device tape tension
Electronic device tape tension standards
Airport loop insulation resistance

《GB/T 1386.2-1997低压电力线路绝缘子 第2部分:架空电力线路用拉紧绝缘子》由TC80(全国绝缘子标准化技术委员会)归口,主管部门为中国电器工业协会。
本标准规定了架空电力线路用拉紧绝缘子的产品型式和尺寸、技术要求、试验方法、检验规则以及包装与标志。


Scope

This standard specifies the product type and size, technical requirements, test methods, inspection rules, packaging and marking of tension insulators for overhead power lines. This standard applies to pole pull wires or tension wires and tension insulators (hereinafter referred to as insulators) used for insulation in power frequency AC or DC overhead power lines. The ambient temperature of its installation and use site is -40~+40℃, and the altitude does not exceed 1000m. When the altitude of the insulator installation site or test site exceeds 1000m, its test voltage value should be corrected according to the relevant standards. Note: Altitude correction method is under consideration. This standard does not apply to insulators used in media that damage porcelain and glaze.

Sample only — not a preview of GB/T 1386.2-1997
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend

  • GB/T 7253-2019 in English

    GB/T 7253-2019 in English

    Insulators for overhead lines with a nominal voltage above 1 000 V—Ceramic or glass insulator units for a.c.systems—Characteristics of insulator units of the cap and pin type

    2019-12-10
  • GB/T 44179-2024 in English

    GB/T 44179-2024 in English

    Composite hollow core station post insulators with a.c. voltage greater than 1 000V and d.c. voltage greater than 1 500V—Definitions,test methods and acceptance criteria

    2024-07-24
  • GB/T 4056-2019 in English

    GB/T 4056-2019 in English

    Dimensions of ball and socket couplings of string insulator units

    2019-12-10
  • GB/T 19443-2017 in English

    GB/T 19443-2017 in English

    Insulators for overhead lines with a nominal voltage above 1 500 V-Ceramic of glass insulator units for d.c.systems-Definitions,test methods and acceptance criteria

    2017-11-01
  • GB/T 34937-2017 in English

    GB/T 34937-2017 in English

    Insulators for overhead lines-Composite suspension and tension insulators for d.c. systems with a nominal voltage greater than 1 500 V-Definitions,test methods and acceptance criteria

    2017-11-01
  • GB/T 12944-2011 in English

    GB/T 12944-2011 in English

    High-voltage ceramic wall bushings

    2011-07-29