Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
horizontal floor wiring-section specification scopethis section symmetrical pair/quad cables detail specification appropriate detail specification horizontal layer wiring changes management requirements badminton competition tecycline medicine residuse
GB/T 18015.2-2007 in English

GB/T 18015.2-2007 in English

SUPERSEDED

Multicore and symmetrical pair/quad cables for digital communications-Part 2:Horizontal floor wiring-Section specification

  • Issued on:2007-01-23
  • Implemented on:2007-08-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $220.00
$214.00
Standard No: GB/T 18015.2-2007
Document status: SUPERSEDED
Superseded by: GB/T 18015.2-2025 Multicore and symmetrical pair/quad cables for digital communications—Part 2: Symmetrical pair/quad cables with transmission characteristics up to 100MHz—Horizontal floor wiring—Sectional specification
Superseded on: 2026-05-01
Title in English: Multicore and symmetrical pair/quad cables for digital communications-Part 2:Horizontal floor wiring-Section specification
Title in Chinese: 数字通信用对绞或星绞多芯对称电缆 第2部分:水平层布线电缆 分规范
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2007-01-23
Implemented on: 2007-08-01
Superseding: GB/T 18015.2-1999 Multicore and symmetrical pair/quad cables for digital communications-Part 2:Horizontal floor wiring-Sectional specification
ICS Classification: 29.060.20-Cables
Chinese Classification: K13-Cable and its accessory
Professional Classification: GB-National Standard
Related Keywords: horizontal floor wiring-section specification scopethis section
symmetrical pair/quad cables
detail specification
appropriate detail specification
horizontal layer wiring
Related Topics: twisted pair for digital communication
twist
Multiple stars
Star Strand
Network symmetrical cable
Star twisted eight-core cable
GB/T 18015.2
GB/T 18015.2-1999
GB/T 18015.2-2007
symmetrical cable
Horizontal twisted pair cable for digital communication
Copper core pair twisted user lead-in cable
Horizontal twisted pair cable standard for digital communications

《GB/T 18015.2-2007数字通信用对绞或星绞多芯对称电缆 第2部分:水平层布线电缆 分规范》由TC213(全国电线电缆标准化技术委员会)归口,主管部门为中国电器工业协会。
本标准与GB/T 18015.1一起使用,这种电缆专用于GB/T 18233中定义的水平层布线。本标准适用于水平层布线的对数少于20个对绞组或10个四线组的电缆。对绞组或四线组可具有或没有单独屏蔽。这种电缆的缆芯可以总有屏蔽。适用于在合适的详细规范中所提到的各种通信系统。


Scope

This section is used together with GB/T 18015.1. This cable is dedicated to the horizontal layer wiring defined in GB/T 18233. This standard applies to cables with fewer than 20 pairs or 10 quads for horizontal layer wiring. Twisted pairs or quads are available with or without individual shielding. The cores of such cables may have an overall screen. This tariff applies to the various communication systems mentioned in the appropriate detail specification. The electricity charges included in this section shall be operated at the voltage and current normally used in the communication system. These electricity bills should not be connected to a low-impedance source such as the public supply. Recommended temperature ranges during installation and operation are specified in the detail specification.

Sample only — not a preview of GB/T 18015.2-2007
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend

  • GB/T 11017.1-2024 in English

    GB/T 11017.1-2024 in English

    Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV(Um=72.5 kV)and 110 kV(Um=126 kV)—Part 1: Test methods and requirements

    2024-09-29
  • GB/T 12972.1-2008 in English

    GB/T 12972.1-2008 in English

    Flexible rubber-sheathed cables for mining purposes - Part 1:General requirements

    2008-06-30
  • GB/T 9326.1-2008 in English

    GB/T 9326.1-2008 in English

    Oil-filled paper or polypropylene paper laminate insulated metal-sheathed cables and accessories for alternating voltages up to and including 500kV - Part 1: Test

    2008-06-30
  • GB/T 22577-2025 in English

    GB/T 22577-2025 in English

    Class 1E cables for nuclear power generating stations—General requirements

    2025-08-29
  • GB/T 33343-2016 in English

    GB/T 33343-2016 in English

    Test methods of insulated electric wires for aerospace

    2016-12-13
  • GB/T 2952.1-2008 in English

    GB/T 2952.1-2008 in English

    Protective coverings for electric cables - Part 1: General

    1982-03-22
  • GB/T 4011-2013 in English

    GB/T 4011-2013 in English

    1.2/4.4 mm composite coaxial cable for telecommunication use

    2013-07-19
  • GB/T 5013.1-2008 in English

    GB/T 5013.1-2008 in English

    Rubber insulated cables of rated voltages up to and including 450/750 V - Part 1:General requiremnts

    2008-01-22
  • GB/T 31489.1-2015 in English

    GB/T 31489.1-2015 in English

    D.C. extruded cable systems for power transmission at a rated voltage up to and including 500 kV―Part 1:Test methods and requirements

    2015-05-15