GB/T 12972.1-2008 in English
VALIDFlexible rubber-sheathed cables for mining purposes - Part 1:General requirements
- Issued on:2008-06-30
- Implemented on:2009-04-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$243.00
| Standard No: | GB/T 12972.1-2008 |
| Document status: | VALID |
| Title in English: | Flexible rubber-sheathed cables for mining purposes - Part 1:General requirements |
| Title in Chinese: | 矿用橡套软电缆 第1部分: 一般规定 |
| Language: | English |
| File Format: | Electronic (PDF) |
| Delivery: | Via email within 1~3 business days |
| Issued on: | 2008-06-30 |
| Implemented on: | 2009-04-01 |
| Superseding: |
GB 12972.1-1991 Flexible rubber-sheathed cables for mining purposes-Part 1: General
|
| ICS Classification: | 29.060.20-Cables |
| Chinese Classification: | K13-Cable and its accessory |
| Professional Classification: | GB-National Standard |
| Related Keywords: | flexible rubber-sheathed cables
electric cables flexible copper-core rubber-insulated/sheathed cables insulated cables cables yb/t |
| Related Topics: | GB/T 12972.1
GB/T 12972.1-2008 |
《GB/T 12972.1-2008矿用橡套软电缆 第1部分: 一般规定》由TC213(全国电线电缆标准化技术委员会)归口,主管部门为中国电器工业协会。
GB/T12972的本部分规定了矿用橡套软电缆产品分类、通用技术要求、试验方法和检验规则。
本部分适用于交流额定电压��0/�瘴�6/10kV 及以下矿用铜芯橡皮绝缘橡皮护套软电缆。
本部分应分别与GB/T12972的后续部分共同使用。
1 Scope
This part of GB/T 12972 specifies the product classification, general technical requirements, test methods and inspection rules of flexible rubber-sheathed cables for mining purposes.
This part is applicable to the flexible copper-core rubber-insulated/sheathed cables with AC rated voltage U0/U of 6/10kV.
This part shall be used together with the subsequent parts of GB/T 12972.
2 Normative References
The following documents contain provisions which, through reference in this part of GB/T 12972, constitute provisions of this part. For dated reference, subsequent amendments to (excluding corrections to), or revisions of, any of these publications do not apply. However, parties to agreements based on this part are encouraged to investigate the possibility of applying the most recent edition of the standard indicated below. For any undated reference, the latest edition of the document referred to applies.
GB/T 2900.10-2001 Electrotechnical Vocabulary - Electric Cables (idt IEC 60050-461:1984)
GB/T 3048.8-2007 Test Methods for Electrical Properties of Electric Cables and Wires - Part 8: AC Voltage Test (IEC 60060-1:1989, NEQ)
GB/T 3048.9-2007 Test Methods for Electrical Properties of Electric Cables and Wires - Part 9: Spark Test of Insulated Cores
GB/T 3048.12-2007 Test Methods for Electrical Properties of Electric Cables and Wires - Part 12: Partial Discharge Test (IEC 60885-3:1988, MOD)
GB/T 3048.13-2007 Test Methods for Electrical Properties of Electric Cables and Wires - Part 13: Impulse Voltage Test (IEC 60230:1966, IEC 60060-1:1989, MOD)
GB/T 3956-1997 Conductors of Insulated Cables (idt IEC 60228: 1978)
JB/T 8137-1999 (All Parts) Delivery Drums for Electric Wires and Cables
YB/T 5294-2006 Low Carbon Steel Wire for General Uses
3 Terms and Definitions
The terms of this part adopt the explanation given in GB/T 2900.10-2001.
3.1
rated voltages
rated voltage is the reference voltage used in cable design and electrical property test, represented by U0/U and expressed in kV
U0 is the RMS voltage between any main insulated-conductor and the "ground" (the metallic screen, metallic sheath or ambient medium)
U is the RMS voltage between any two-phase conductors in the multi-core or single-core cable system
When the cable is used for AC system, the rated voltage of cable shall at least be the rated voltage of this system; when the cable is used for DC system, the rated voltage of this system shall not be greater than 1.5 times the rated voltage of cable
The working voltage of system shall not be greater than 1.1 times the rated voltage of system
3.2
type tests
T
tests done on a kind of cables specified in this standard according to the general commercial principles before delivery of goods, in order to prove that the cables have good performance and meet the specified operating requirements
Note: for the essence of type tests, once these tests are carried out, there is no need to repeat unless the change of cable material or design may affect the cable performance.
3.3
sample tests
Foreword I
1 Scope
2 Normative References
3 Terms and Definitions
4 Product Codes, Presentation Methods and Examples
5 Technical Requirements
6 Inspection Rules
7 Packaging
8 Transportation and Storage
Annex A (Normative ) Mechanical and Physical Property Requirements of Rubber Insulation
Annex B (Normative) Mechanical Shock Test Method
Annex C (Normative) Squeeze Test Method
Annex D (Normative) Bend Test Method
Annex E (Normative) Transition Resistance Test Method
Annex F (Normative) Water Absorption Test Method for Insulation

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 18014-2008 in English
PVC insulated wire for ignition of electric detonators
2008-06-18 -

GB/T 11017.1-2024 in English
Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV(Um=72.5 kV)and 110 kV(Um=126 kV)—Part 1: Test methods and requirements
2024-09-29 -

GB/T 9326.1-2008 in English
Oil-filled paper or polypropylene paper laminate insulated metal-sheathed cables and accessories for alternating voltages up to and including 500kV - Part 1: Test
2008-06-30 -

GB/T 29631-2025 in English
Flexible and torsion resistant cables of rated voltages up to and including 1.8/3 kV for wind turbine
2025-02-28 -

GB/T 18380.11-2022 in English
Tests on electric and optical fibre cables under fire conditions—Part 11:Test for vertical flame propagation for a single insulated wire or cable—Apparatus
2022-03-09 -

GB/T 2952.1-2008 in English
Protective coverings for electric cables - Part 1: General
1982-03-22 -

GB/T 33343-2016 in English
Test methods of insulated electric wires for aerospace
2016-12-13 -

GB/T 19216.1-2021 in English
Circuit integrity test for electric cables or optical fiber cables under fire conditions—Part 1: Test method for fire with shock at a temperature of at least 830 ℃ for cables of rated voltage up to and including 0.6/1 kV and with an overall diameter exceeding 20 mm
2021-05-21