Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
glass insulator units overhead lines overhead power lines nominal voltage d.c. lines microbeam analysis determination method unified wear test standard infusion bag
GB/T 19443-2004 in English

GB/T 19443-2004 in English

SUPERSEDED

Insulators for overhead lines with a nominal voltage above 1 000 V - Ceramic or glass insulator units for d.c. systems - Difinitions,test methods and acceptance criteria

  • Issued on:2004-02-04
  • Implemented on:2004-08-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $240.00
$233.00
Standard No: GB/T 19443-2004
Document status: SUPERSEDED
Superseded by: GB/T 19443-2017 Insulators for overhead lines with a nominal voltage above 1 500 V-Ceramic of glass insulator units for d.c.systems-Definitions,test methods and acceptance criteria
Superseded on: 2018-05-01
Title in English: Insulators for overhead lines with a nominal voltage above 1 000 V - Ceramic or glass insulator units for d.c. systems - Difinitions,test methods and acceptance criteria
Title in Chinese: 标称电压高于 1000V 的架空线路用绝缘子-直流系统用瓷或玻璃绝缘子元件-定义、试验方法和接收准则
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2004-02-04
Implemented on: 2004-08-01
ICS Classification: 29.080.10-Insulators
Chinese Classification: K48-Insulator
Professional Classification: GB-National Standard
Related Keywords: glass insulator units
overhead lines
overhead power lines
nominal voltage
d.c. lines
Related Topics: iec nominal voltage
insulator
iec DC insulator
Q
Q
standard insulator
GBT19443
GB/T 19443-2004
GBT19443-2017
Device insulation withstand voltage test at high altitude
DC withstand voltage test
gb19443

《GB/T 19443-2004标称电压高于1000V的架空线路用绝缘子----直流系统用瓷或玻璃绝缘子元件----定义、试验方法和接收准则》由TC80(全国绝缘子标准化技术委员会)归口,主管部门为中国电器工业协会。
本标准适用于标称电压高于1000V的直流架空电力线路用瓷或玻璃绝缘子串件。本标准不适用于有机复合绝缘子。本标准对绝缘子在直流电压下其他状态的应用由有关技术委员会考虑。


Scope

This standard applies to porcelain or glass insulator string components for DC overhead power lines with a nominal voltage higher than 1000V. This standard does not apply to organic composite insulators. The application of this standard to other conditions of insulators under DC voltage is considered by the relevant technical committee. This standard specifies: - technical requirements, dimensions and characteristics of insulators; - conditions for testing the specified values of these characteristics; - acceptance criteria. This standard specifies basic characteristic tests similar to IEC 60383-1. In order to ensure satisfactory long-term performance of DC insulators, some tests must be added. Currently, these additional tests are only relevant to disc suspension insulators. In view of the lack of valid data on the performance of long rod insulators for d.c. lines, it is currently not possible to specify or confirm tests suitable for such insulators at d.c. This standard does not include requirements for the selection of insulators or special tests for specific operating conditions, for example, aging caused by specific operating conditions.

Sample only — not a preview of GB/T 19443-2004
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend

  • GB/T 44179-2024 in English

    GB/T 44179-2024 in English

    Composite hollow core station post insulators with a.c. voltage greater than 1 000V and d.c. voltage greater than 1 500V—Definitions,test methods and acceptance criteria

    2024-07-24
  • GB/T 26218.1-2010 in English

    GB/T 26218.1-2010 in English

    Selection and dimensioning of high-voltage insulators intended for use in polluted conditions—Part 1:Definitions,information and general principles

    2011-01-14
  • GB/T 4056-2019 in English

    GB/T 4056-2019 in English

    Dimensions of ball and socket couplings of string insulator units

    2019-12-10
  • GB/T 34937-2017 in English

    GB/T 34937-2017 in English

    Insulators for overhead lines-Composite suspension and tension insulators for d.c. systems with a nominal voltage greater than 1 500 V-Definitions,test methods and acceptance criteria

    2017-11-01
  • GB/T 11030-2008 in English

    GB/T 11030-2008 in English

    Characteristics of rod ceramic insulators for a.c. contact system of electrified railways

    2008-06-30
  • GB/T 20642-2006 in English

    GB/T 20642-2006 in English

    Impulse puncture test in air on insulators for overhead lines

    2006-11-08
  • GB/T 19443-2017 in English

    GB/T 19443-2017 in English

    Insulators for overhead lines with a nominal voltage above 1 500 V-Ceramic of glass insulator units for d.c.systems-Definitions,test methods and acceptance criteria

    2017-11-01
  • GB/T 22707-2008 in English

    GB/T 22707-2008 in English

    Artificial pollution tests on high-voltage insulators to be used on d.c. systems

    2008-12-30