Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
digital display phase meter power factor meters introduction power factor meter power factor meter specific definitions phase meters separate detection method need electric anchor drill motors forensic science toner inspection infrared spectroscopy introduction technical background
GB/T 22264.5-2022 in English

GB/T 22264.5-2022 in English

VALID

Mounted digital display electric measuring instruments—Part 5:Special requirements for phase meters and power factor meters

  • Issued on:2022-12-30
  • Implemented on:2023-07-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $190.00
$185.00
Standard No: GB/T 22264.5-2022
Document status: VALID
Title in English: Mounted digital display electric measuring instruments—Part 5:Special requirements for phase meters and power factor meters
Title in Chinese: 安装式数字显示电测量仪表 第5部分:相位表和功率因数表的特殊要求
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2022-12-30
Implemented on: 2023-07-01
Superseding: GB/T 22264.5-2008 Mounted digital display electric measuring instruments - Part 5: Special requirements for phase meters and power factor meters
ICS Classification: 17.220.20-Measurement of electrical and magnetic quantities
Chinese Classification: N23-Digital display instrument
Professional Classification: GB-National Standard
Related Keywords: digital display phase meter
power factor meters introduction
power factor meter
power factor meter specific definitions
phase meters
Related Topics: Instruments that can measure boundaries
electrical measurement
Power Factor Meter
Power Factor Meter
Potential indication
factor
phase table
How to display all the tables
Single Phase Power Factor Meter
Single Phase Power Factor Meter
Boundary measuring instrument
Power of each meter
Factor value table
functional epitope
GB/T 22264.5
GB/T 22264.5-2008
What is the power factor of the power detector?
How the power factor measuring meter works
Double clamp digital phase voltammeter
digital dial indicator
How to set up the power digital display
digital electric meter
Chaohu digital display instrument
Chuzhou digital display instrument

《GB/T 22264.5-2022安装式数字显示电测量仪表 第5部分:相位表和功率因数表的特殊要求》由TC104(全国电工仪器仪表标准化技术委员会)归口,TC104SC2(全国电工仪器仪表标准化技术委员会电工和电磁量测量设备分会)执行,主管部门为中国机械工业联合会。


Introduction

1. Background and significance of standard formulation

GB/T22264 series standards are important specifications in the field of electrical instruments in my country and have been used for more than ten years. With the advancement of technology and changes in market demand, some contents of the original standards have become outdated and urgently need to be revised to adapt to the development of new technologies.


2. Comparative analysis of standard frameworks

Standard version Main clauses Technical updates
2008 edition Definition of phase meter and power factor meter Specific definitions have been deleted and unified into the category of instruments
2022 edition Nominal voltage and current range Add clear definition of nominal voltage and current
New content Electromagnetic compatibility requirements Detailed test conditions and value application methods

3. Technology Update and Evolution Analysis

5.1 Standard Electricity Value: Added the range definition of nominal voltage and current, and clarified the frequency measurement requirements. Applicable to distribution systems with AC below 690V and nominal frequency of 50Hz or 60Hz.

5.2 Reference Conditions and Basic Errors: Table 1 updates the allowable deviation range, and the voltage and current deviations are optimized from ±2% to ±1.0%, improving the measurement accuracy requirements. Added the angle deviation limit (≤2°) under phase balance conditions.


4. Implementation suggestions and precautions

Case study: Instrument selection for a power distribution system

For a distribution cabinet with a rated voltage of 400V and a frequency of 50Hz, when selecting a digital display phase meter and power factor meter that meet the requirements of GB/T22264.5-2022:

  • Confirm the instrument accuracy grade index (it is recommended to use 0.1 or 0.2 grade)
  • Verify whether the overload protection function meets the requirements of the short-term overload test (as specified in Table 3)
  • Check the electromagnetic compatibility indicators to ensure that the anti-interference and disturbance suppression capabilities meet the actual working conditions

Sample only — not a preview of GB/T 22264.5-2022
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend

  • GB/T 22264.1-2022 in English

    GB/T 22264.1-2022 in English

    Mounted digital display electric measuring instruments—Part 1:Definitions and general requirements common to all parts

    2022-04-15
  • GB/T 14913-2008 in English

    GB/T 14913-2008 in English

    Digital electronic d.c. voltmeters and d.c. electronic analogue-to-digital convertors

    2008-08-06