Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
continuous thermocouple continuous thermocouple cable armored continuous thermocouple cable continuous thermocouple cables continuous thermocouple kk positron emission tomography device ferrous metal surfaces white spot disease scopethis part
GB/T 36016-2018 in English

GB/T 36016-2018 in English

VALID

Sheathed continuous thermocouple cables and sheathed continuous thermocouple

  • Issued on:2018-03-15
  • Implemented on:2018-10-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $210.00
$204.00
Standard No: GB/T 36016-2018
Document status: VALID
Title in English: Sheathed continuous thermocouple cables and sheathed continuous thermocouple
Title in Chinese: 铠装连续热电偶电缆及铠装连续热电偶
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2018-03-15
Implemented on: 2018-10-01
ICS Classification: 17.200.20-Temperature-measuring instruments
Chinese Classification: N11-Temperature and pressure instrument
Professional Classification: GB-National Standard
Related Keywords: continuous thermocouple
continuous thermocouple cable
armored continuous thermocouple cable
continuous thermocouple cables
continuous thermocouple kk
Related Topics: thermocouple
thermoelectric
Armored continuous thermocouple cable and armored continuous thermocouple
How to Repair a Thermocouple
Thermocouple Repair
Thermocouple Repair
galvanic couple
k-type thermocouple
Potentiometer field discontinuity
Crystalline thermocouple
surface thermocouple
gb/t36016
continued
Coupling surface
Armored Continuous Thermocouple
Thermocouple subzero
GB/T 36016-2018
Thermocouple Function
GBT36016
GB/T 36016-2018
Thermocouple measuring range
Cable armor
Armoured
Armored heating
Armored RTD Execution
Thermocouple abnormality
Armored Thermocouple Accuracy Class
Armored thermal resistor
Armored control cable grounding
Galvanic current test
Standard Thermocouple Wholesale
Armored cable grounding
Thermocouple Germany
Armored thermal resistance national standard
The correct way to connect a thermocouple
thermocouple military
Industrial armored thermal resistor

《GB/T 36016-2018铠装连续热电偶电缆及铠装连续热电偶》由TC419(全国仪表功能材料标准化技术委员会)归口,主管部门为中国机械工业联合会。


Introduction

Interpretation of the core content of the standard

GB/T 36016-2018 specifies the key technical requirements for armored continuous thermocouple cable and its components:

Technical indicatorsParameter requirementsTest methods
Working temperature range80-800℃Appendix A Graduation table
Tolerance levelGrade I ±6℃/3%t; Grade II ±10℃/5%t5.4 Thermoelectric performance test
Uniformity (300℃)≤15℃5.5 Uniformity test
Minimum bending radius20 times the outer diameter5.7 Bending test

Product structure characteristics

The standard defines two typical structures:

  1. Armored continuous thermocouple cable: a three-layer structure consisting of thermocouple wire, thermal sensitive material and metal protection tube
  2. Armored continuous thermocouple: a complete temperature measurement component of cable + connector + compensation wire

Detailed explanation of key technical requirements

4.4 Thermoelectric performance and tolerance

Using the Seebeck coefficient mathematical model (Formula A.1), the thermoelectric emf rate of the main temperature points is:

  • At 300℃: 41.32μV/℃
  • At 600℃: 42.54μV/℃
  • At 800℃: 41.10μV/℃

5.4 Thermoelectric performance test

Test equipment requirements:

Temperature rangeConstant temperature box specificationsElectrical measuring instrument requirements
≤300℃400×400×300mm, uniformity≤2℃Input impedance≥10MΩ, error≤0.05%
>300℃300×300×200mm, uniformity ≤5℃resolution ≥2μV

Engineering application suggestions

Selection guide

Product marking example: WLKK-211-I-3.0 means:

  • W: connected temperature instrument
  • L: continuous thermocouple
  • KK: armored + K type thermocouple
  • 2: double core structure
  • 1: inseparable integrated joint
  • I: Class I tolerance
  • 3.0: outer diameter 3.0mm

Installation precautions

  1. Bending radius ≥20 times cable outer diameter
  2. Immersion applications require end sealing (welding/sealant)
  3. Customized length within the range of 2-40m, positive deviation ≤0.1m

Standard Evolution Analysis

This standard systematically regulates the following for the first time:

  • Thermo-electromotive force-temperature characteristic mathematical model
  • Complete product marking system
  • Protective tube integrity detection method
  • Standardized structure based on Inconel600 alloy

Sample only — not a preview of GB/T 36016-2018
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend