Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
paper products determination paper products paper industry toilet paper paper product characteristics bearer capacitor clip butt tank-type capacitor voltage transformers
GB/T 37860-2019 in English

GB/T 37860-2019 in English

VALID

Paper,board and paper products—Determination of phthalates

  • Issued on:2019-08-30
  • Implemented on:2020-03-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $220.00
$214.00
Standard No: GB/T 37860-2019
Document status: VALID
Title in English: Paper,board and paper products—Determination of phthalates
Title in Chinese: 纸、纸板和纸制品 邻苯二甲酸酯的测定
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2019-08-30
Implemented on: 2020-03-01
Chinese Classification: Y30-Papermaking in general
Professional Classification: GB-National Standard
Related Keywords: paper products determination
paper products
paper industry
toilet paper
paper product characteristics
Related Topics: dicarboxylate
Phthalates
Phthalates+
Phthalate test
iso phthalic acid
Phthalates en
Phthalates double
Formic acid
Phthalate+
phthalate alcohol
Indicators for phthalates
Rapid detection method for phthalates
Fertilizer Phthalates
Chroma of Phthalates
Phthalates
Soil Phthalates
How to Detect Phthalates
Phthalic acid diesters
Phthalates
Soil Phthalates Testing
Phthalates Infrared
In the determination of benzene, toluene, ethylene o-xylene
Air Phthalates Determination
Phthalates + Infrared
Zirconium Bromophthalate
Phthalates Infrared
Phthalates Detection
Phthalate Rapid Test
Soil Phthalates Determination
Phthalates Determination
Phthalic acid determination
Infrared Spectrum of Phthalates
Phthalates and Detection
Method for the detection of phthalic acid diesters
Phthalarsine
Phthalate Ash
Phthalate Ash
Rubber Products Phthalates
Phthalate test
Phthalate Preparation
Phthalic acid
lead phthalate
Benzoic acid in meat products
Gas Determination of Phthalates
Phthalate heating
Detection of phthalic acid in water
o-xylene peak
paper products
paper products
Portable Gas Determination of Phthalates
18 phthalates and 16 phthalates
Meat Benzoic Acid
Phthalic acid photometry
What is phthalic acid
How to measure phthalic acid
Phthalate test
How to Detect Phthalates
Cardboard formaldehyde
Benzoic Meat Products
Phthalates Detection
Phthalene
Phthalate testing
Method for determination of phthalic acid by liquid phase
disulfone phthalate
Determination of phthalic acid
GBT37860
Infrared spectrum of phthalates
acid free paper
Phthalate transport in plants
Disinfectants Determination of Phthalates
Phthalate standard samples have certificates
What are the liquid quality methods for determining phthalates?
Determination method of diphenyl phosphate
Methanesulfonic acid control limit establishment
Phthalic acid product quality
Detection of o-phthalaldehyde
Phthalate detection
gb/t 37860-2019

《GB/T 37860-2019纸、纸板和纸制品 邻苯二甲酸酯的测定》由TC141(全国造纸工业标准化技术委员会)归口,主管部门为中国轻工业联合会。


Introduction

GB/T 37860-2019 Standard Overview

GB/T 37860-2019, the national standard of the People's Republic of China, specifies the gas chromatography-mass spectrometry (GC-MS) method for the determination of 19 phthalates in paper, paperboard and paper products. This standard is applicable to the detection of phthalates in various paper and products, including toilet paper, wet wipes, diapers and other samples.

Background of Standard Formulation

Phthalates are plasticizers widely used in plastics, resins and adhesives. Due to their potential environmental and health risks, countries have increasingly stringent requirements for the limit of phthalates in paper products. This standard was proposed by the China Light Industry Federation and is under the jurisdiction of the National Technical Committee for Standardization of Paper Industry (SAC/TC141). It aims to provide the industry with scientific and unified detection methods.

Technology Evolution Analysis

Compared with the old version of the standard, GB/T 37860-2019 has achieved technological breakthroughs in the following aspects:

  • GC-MS Hybrid Technology Optimization: The use of the characteristic selected ion monitoring scan mode (SIM) significantly improves the detection sensitivity and accuracy.
  • Sample pretreatment process improvement: Ultrasonic assisted extraction greatly shortens the analysis time and reduces the amount of reagents.
  • Qualitative and quantitative method innovation: The combination of full scan mode (TIC) and selected ion monitoring mode (SIM) ensures the reliability of qualitative results, and the external standard method is used for quantification.

Comparison table of standard frameworks

Project GB/T 37860—2019 International similar standards
Detection range 19 phthalates, with different limits of quantification (some are 2.0-50.0 mg/kg) Usually covers 16-18 ester substances
Detection method Gas chromatography-mass spectrometry (GC-MS), characteristic ion monitoring mode (SIM) Mostly using GC-FID or LC-MS methods
Sample processing Ultrasonic assisted extraction, suitable for a variety of paper product characteristics Traditional Soxhlet extraction

Implementation suggestions

Laboratory conditions requirements:

  • Equipped with Gas chromatograph-mass spectrometer (GC-MS) to meet the parameter requirements specified in the standard.
  • Have secondary or above analytical laboratory qualifications to ensure data reliability.
  • Operators need to undergo professional training and be familiar with sample pretreatment and instrument operation procedures.

Precautions in practical application:

  • For complex samples (such as wet wipes and toilet paper), it is recommended to dry them first and then crush them to ensure extraction efficiency.
  • Pay attention to the ultrasonic extraction temperature and time to avoid sample decomposition or volatilization.
  • Regularly calibrate the instrument, especially the ionization source and interface temperature of the mass spectrometer.

Quality control suggestions:

  • Use standard substances to establish a complete calibration curve and perform periodic verification.
  • Set up a blank control for each batch of samples to ensure the validity of the analysis results.
  • For high-content samples, use the dilution method to avoid instrument overload.

Sample only — not a preview of GB/T 37860-2019
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend