| Standard No: | GB/T 38704-2020 |
| Document status: | VALID |
| Title in English: | Frame system of timber supporting curtain wall |
| Title in Chinese: | 建筑木框架幕墙组件 |
| Language: | English |
| File Format: | Electronic (PDF) |
| Delivery: | Via email within 5 business days |
| Issued on: | 2020-03-31 |
| Implemented on: | 2021-02-01 |
| ICS Classification: | 91.060.10-Walls. Partitions. Facades |
| Chinese Classification: | P32-Building construction and decoration engineering |
| Professional Classification: | GB-National Standard |
| Related Keywords: | curtain wall introduction interpretation
use area wood moisture content meter wind pressure standard technical dimensions key requirements test methods glued wood strength frame system flexural strength ≥28mpa gb/t26899-2011 moisture content control |
| Related Topics: | curtain wall
wooden frame use GBT38704 GB/T 38704-2020 european curtain wall components European and domestic standards for building curtain walls |
《GB/T 38704-2020建筑木框架幕墙组件》由TC448(全国建筑幕墙门窗标准化技术委员会)归口,主管部门为住房和城乡建设部。
Introduction
Interpretation of the core content of the standard
| Technical dimensions | Key requirements | Test methods |
|---|---|---|
| Glued wood strength | Not less than TCr21/TCvp18 grade, flexural strength ≥28MPa | GB/T26899-2011 |
| Moisture content control | 6%-13%, 1%-3% lower than the equilibrium moisture content of the use area | Wood moisture content meter |
| Wind pressure bearing | Deflection ≤ 1/250 of span and ≤ 20mm | Appendix B Test Method |
Key Technical Requirements
1. Material Specifications
Glued wood must meet the following requirements: Fire resistance ≥ B1, Formaldehyde emission up to F☆☆☆, visible surface strip length > 250mm. Water-based paint must pass the 168h yellowing resistance test (ΔE≤3.0).
2. Connection structure
- Beam-column connection points ≥2, screw diameter ≥4.5mm
- Cross-layer connection hole diameter ≥15mm, spacing ≥3 times the hole diameter
- Panel fixing component spacing ≤250mm
Implementation points
Solutions to typical engineering problems
Case:In a project, the displacement of the connection part of the 180mm column exceeded the standard in the 3.5kPa wind pressure test. Upon review, it was found that:
1) The double-layer installation holes were not set according to the standard requirements
2) The thickness of the connector was insufficient, resulting in a decrease in stiffness
Corrective measures: Use stainless steel connectors with a thickness of ≥6mm and increase the number of M10 bolts to 3.
Analysis of Standard Evolution
Compared with traditional steel-aluminum curtain walls, this standard establishes for the first time:
• Dynamic control principle of moisture content of wood structures
• Gravity/wind pressure bidirectional bearing performance grading system
• Normative Appendix on strength characteristic values and elastic modulus of integrated wood (Appendix A)

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 30593-2025 in English
External wall interior insulation composite panel system
2025-10-31 -

GB/T 36140-2018 in English
Technical requirements for assembled insulation combination wall composite by glass fiber reinforced inorganic materials
2018-05-14 -

GB/T 34327-2017 in English
Terminology for curtain wall
2017-10-14 -

GB/T 18091-2015 in English
Optical and thermal performance of glass curtain wall
2015-09-11 -

GB/T 21086-2007 in English
Curtain Wall for Building
2007-11-09 -

GB/T 29043-2023 in English
Test method for thermal insulating performance of curtain walls
2023-12-28 -

GB/T 38264-2019 in English
Classification and test method of resistance against impact for curtain wall
2019-12-10 -

GB/T 30594-2014 in English
Thermal performance of double-skin glass facade—Tracer gas mehtod
2014-06-09