GB/T 43892-2024 in English
VALIDTest method for spectral transmittance of quartz glass
- Issued on:2024-04-25
- Implemented on:2024-11-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$185.00
《GB/T 43892-2024石英玻璃光谱透射比试验方法》由TC447(全国工业玻璃和特种玻璃标准化技术委员会)归口,主管部门为中国建筑材料联合会。
Introduction
1. Standard Overview
GB/T 43892—2024 Test Method for Spectral Transmittance of Quartz Glass is the latest national standard issued by the People's Republic of China, which is used to regulate the spectral transmittance test of quartz glass in different wavelength ranges. This standard was proposed by the China Building Materials Federation and is managed by the National Technical Committee for Standardization of Industrial Glass and Special Glass.
2. Background of Standard Formulation
With the increasing demand for high-performance quartz glass in the fields of optics, optoelectronics, etc., it is essential to accurately measure its spectral transmittance characteristics. This standard is based on the principle of spectrophotometer and combined with industry practical experience, aiming to provide unified technical specifications for related product testing.
3. Comparison of standard frameworks
| Chapter | GB/T 43892—2024 | Comparison description |
|---|---|---|
| Scope | Applicable to the spectral transmittance test of quartz glass, other materials can be used for reference. | Added detailed provisions for curved surface specimens. |
| Terms and definitions | GB/T13962 and JC/T 2205 are referenced to ensure terminology consistency. | Added mathematical expressions for spectral transmittance. |
| Instruments and Equipment | Specify the technical indicators and test conditions of the spectrophotometer in detail. | Added requirements and usage suggestions for the integrating sphere. |
4. Implementation Suggestions
4.1 Preparation before testing
Ensure that the spectrophotometer is warmed up for at least 10 minutes to obtain stable measurement results. For curved samples, it is recommended to use a sample holder and adjust the incident spot size to the recommended range to reduce refraction and reflection errors.
4.2 Data Processing and Reporting
When processing data, it is recommended to record the transmittance value at the specified wavelength and calculate the arithmetic mean of the transmittance within the wavelength range. The test report should include detailed information about the sample, test conditions and results.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB 2629-1981 in English
Enamel dough basins
- -

GB/T 19720-2024 in English
Jewellery and precious metals—Determination of platinum and palladium—Gravimetry using ammonium chloride and dimethylglyoxime
2024-03-15 -

GB/T 11563-1995 in English
Motor vehicles--Procedure for H-point determination
- -

GB/T 24-1976 in English
Bolts, small hexagon head with fit neck and hole through the shank
- -

GB 10551-1989 in English
Photographic grade sodium thiosulfate, crystilline
1989-12-01 -

GB/T 4937.34-2024 in English
Semiconductor devices—Mechanical and climatic test methods—Part 34:Power cycling
2024-03-15 -

GB 6220-2023 in English
Respiratory protection—Air line respirator
2023-12-28 -

GB/T 13220-1991 in English
Determination of particle size distribution of fine powder-Method of sieve classfication with sonic wave
1991-10-05 -

GB/T 7408.1-2023 in English
Date and time—Representations for information interchange—Part 1: Basic rules
2023-12-28 -

GB/T 40096.6-2024 in English
Technical specification for on-site relay protection equipment—Part 6: Busbar protection
2024-04-25