Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
coal water mixture carbon determination coal samples coal sample dry coal samples liquefied natural gas plant brass foil scopethis standard arc ignition test method
GB/T 476-2008 in English

GB/T 476-2008 in English

VALID

Determination of carbon and hydrogen in coal

  • Issued on:2008-07-29
  • Implemented on:2009-05-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $180.00
$175.00
Standard No: GB/T 476-2008
Document status: VALID
Title in English: Determination of carbon and hydrogen in coal
Title in Chinese: 煤中碳和氢的测定方法
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2008-07-29
Implemented on: 2009-05-01
Superseding: GB/T 15460-2003 Determination of carbon and hydrogen in coal--Coulometric and gravimetric method
GB/T 18856.11-2002 Test methods for quality of coal water mixture-Part 11-Determination of carbon and bydrogen in coal water mixture
GB/T 476-2001 Ultimate analysis of coal
ICS Classification: 73.040-Coals
Chinese Classification: D21-Coal analysis methods
Professional Classification: GB-National Standard
Related Keywords: coal water mixture
carbon determination
coal samples
coal sample
dry coal samples
Related Topics: hydrocarbon
carbon determination method
Determination method of total carbon and hydrogen
How to measure carbon in water
hydrocarbon
Hydrogen assay
carbon coal
hydrocarbon ring
hydrogen method
coal
Carbon Determination Method
carbon determination method
full carbon of coal
carbon coal
gb/t476
Praseodymium Hydrocarbons
GB/T476-2008
Coal-based carbon carbon carbon
Inorganic Carbon Determination Method
GBT476
GB/T 476-2001
GB/T 476-2008
carbon and hydrogen
carbon in coal
GB/T 476
Hydrogen detection method
Two hydrogen sulfide determination methods in the fourth edition
Determination method of coal organic carbon and inorganic carbon
Determination method of fixed carbon in carburizing agent
Method for determination of organic carbon in plant samples
Determination method of lithium in coal
How to detect carbon-carbon double bonds
Dehydrogenation detection method
gb t 476-2008
gb/t t476-2008
How to measure hydrogen gas
gb 476
gbt476

《GB/T 476-2008煤中碳和氢的测定方法》由TC42(全国煤炭标准化技术委员会)归口,TC42SC1(全国煤炭标准化技术委员会煤炭检测分会)执行,主管部门为中国煤炭工业协会。
本标准代替GB/T 476-2001《煤的元素分析方法》中第3章碳氢测定、GB/T 15460-2003《煤中碳和氢的测定方法 电量-重量法》和GB/T 18856.11-2002《水煤浆质量试验方法 第11部分:水煤浆碳氢测定方法》。
本标准规定了煤和水煤浆中碳氢分析的三节炉法、二节炉法及用电量法测定煤及水煤浆干燥煤样中的氢、用重量法测定碳的方法原理、试剂和材料、装置、试验步骤、结果计算及精密度等。
本标准适用于褐煤、烟煤、无烟煤和水煤浆。
本标准与GB/T 476-2001相比,主要变化如下:
―――增加了煤中碳氢测定的电量�仓亓糠ǎ�
―――增加了水煤浆的碳氢测定;
―――删除氮的测定方法。


1 Scope

This standard specifies the principle, reagents and materials, equipment, test procedures, calculation of results and precision for determination of carbon and hydrogen in coal and coal water mixture by Liebig method, determination of hydrogen in coal and dry coal samples of coal water mixture by coulometric method, and determination of carbon by grametric method.

This standard is applicable to lignite, soft coal, anthracite and coal water mixture.

2 Normative References

The following normative documents contain provisions which, through reference in this text, constitute provisions of this standard. For dated references, subsequent amendments (excluding corrections), or revisions, of any of these publications do not apply to this standard. However, parties to agreements based on this standard are encouraged to investigate the possibility of applying the most recent editions of the normative documents indicated below. For undated references, the latest edition of the normative document referred to applies.

GB/T 212 Proximate Analysis of Coal (GB/T 212-2008, ISO 11722:1999, ISO 1171:1997, ISO 562:1998, NEQ)
GB/T 218 Determination of Carbon Dioxide Content in the Mineral Carbonates Associated with Coal (GB/T 218-1996, eqv ISO 925:1980)
GB/T 18856.1 Test Methods for Quality of Coal Water Mixture — Part 1: Sampling

3 Liebig Method (Three-section Furnace and Two-section Furnace)

3.1 Principle

A known mass of coal sample or coal water mixture is burnt in a current of oxygen in a tube impervious to gases, and the water and carbon dioxide generated are absorbed by water absorbent and carbon dioxide absorbent respectively. The mass fraction of carbon and hydrogen in coal is calculated by the increment of absorbent. The interference of sulfur and chlorine on carbon determination in coal samples was eliminated by lead chromate and silver coil in three-section furnace, and by pyrolysis products of silver permanganate in two-section furnace. The interference of nitrogen to carbon determination was eliminated by granular manganese dioxide.


3.2 Reagents and materials

3.2.1 Magnesium perchlorate, anhydrous, particle size 1 mm to 3 mm; or anhydrous calcium chloride: anhydrous, particle size 2 mm to 5 mm.

3.2.2 Granular manganese dioxide: chemically pure, commercially available or prepared from manganese sulfate and potassium permanganate.

Preparation method: 25 g manganese sulfate was weighed and dissolved in 500 mL distilled water, and 16.4 g potassium permanganate was weighed and dissolved in 300 mL distilled water. The two solutions were heated to 50°C to 60°C respectively. The potassium permanganate solution is slowly injected into the manganese sulfate solution under constant agitation and is stirred vigorously. Then add 10 mL (1+1) sulfuric acid. The solution was heated to 70°C to 80°C and stirred for 5 min, then the heating was stopped. Keep it still for 2 to 3 h. Wash to neutral by pouring hot distilled water. The precipitate was moved to a funnel for filtration to remove water, and then put into a drying oven to dry at 150°C for 2 to 3 h to obtain brown and loose manganese dioxide. It was carefully broken and screened, and the particle size was 0.5 mm to 2 mm for use.

3.2.3 Copper wire coil: of wire diameter approximately 0.5mm. Copper gauze: 0.15mm (100 mesh).

3.2.4 Copper oxide, chemically pure, wire form (approximately 5 mm long).

3.2.5 Lead chromate, anhydrous, fused, size range 1 mm to 4 mm.

Preparation method: The commercially available lead chromate is made into a paste with distilled water and extruded. Put them into muffle furnace and burn them at 850°C for 2 h. Take them out and cool them for reserve.

3.2.6 Copper wire coil: of wire diameter approximately 0.25mm.

3.2.7 Oxygen: 99.9%. Hydrogen-free. Oxygen cylinders shall be fitted with pressure gauges with adjustable flow reducing valves (medical oxygen inhalers may be used).

3.2.8 Tungsten trioxide: anhydrous.

3.2.9 Alkali asbestos: chemically pure, particle size 1 mm to 2 mm; or alkali lime: chemical pure, particle size of 0.5 mm to 2 mm.

3.2.10 Vacuum silicone grease.

3.2.11 Pyrolysis products of silver permanganate: When two-section furnace is used, pyrolysis products of silver permanganate shall be prepared. The preparation method is as follows:

Dissolve 100 g potassium permanganate (chemically pure) in 2 L distilled water and boil. In addition, take 107.5g of silver nitrate (chemically pure) and dissolve it in about 50 mL distilled water, and slowly injected into boiling potassium permanganate solution under constant agitation. After being stirred evenly, it shall be gradually cooled and left standing overnight. The dark purple crystals generated shall be washed several times with distilled water and dried at 60°C to 80°C for 1 h. Then a small part of the crystals shall be placed in a porcelain dish and slowly heated on an electric furnace until they suddenly decomposed into silver-gray loose products, which are put into a grinding bottle for reserve.

Warning: Undecomposed silver permanganate is vulnerable to heat decomposition and shall not be stored in large quantities.

3.2.12 Sulfuric acid: chemically pure.

3.2.13 Glass tube or small dryer with grinding stopper (without desiccant).

3.3 Apparatus

Foreword II
1 Scope
2 Normative References
3 Liebig Method (Three-section Furnace and Two-section Furnace)
4 Coulometric and Gravimetric Method
5 Precision
6 Test Report
Annex A (Informative) Comparison of Clause Numbers in This Standard and the Equivalent Clauses in ISO 625:1996
Annex B (Informative) Technical Deviations between This Standard and ISO 625:1996 and Their Justifications

Page: 1 / 0