GB/T 5013.2-2008 in English
VALIDRubber insulated cables of rated voltages up to and including 450/750V—Part 2:Test methods
- Issued on:2008-01-22
- Implemented on:2008-09-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$117.00
《GB/T 5013.2-2008额定电压450/750V及以下橡皮绝缘电缆 第2部分:试验方法》由TC213(全国电线电缆标准化技术委员会)归口,主管部门为中国电器工业协会。
本部分给出了GB/T 5013的所有部分规定的而没有包括在GB/T2951中的试验方法。本部分为GB/T5013的第2部分。本部分等同采用IEC60245-2:1998《额定电压450/750V 及以下橡皮绝缘电缆 第2部分:试验方法》(英文版)。 本部分从实施之日起代替GB5013.2―1997。
本部分与GB5013.2―1997相比主要变化如下:
―――3.1“曲挠试验”内容重新编排,并对重锤重量、滑轮直径和施加电流等参数做了修改补充;
―――增加了3.5“三轮曲挠试验”和3.6“扭绞试验”;
―――第4章中分别用“IE4”、“空气”和“8.2”替代原文的“IE1”、“氧”和“8.3”。
1 General
1.1 Scope
This Part of GB/T 5013 gives the test methods specified in all parts of GB/T 5013 as far as not laid down in GB/T 2951.
1.2 Normative references
The following normative documents contain provisions which, through reference in this text, constitute provisions of this Part of GB/T 5013. At the time of publication, the editions indicated were valid. All normative documents are subject to revision and parties to agreements based on this Part are encouraged to investigate the possibility of applying the most recent editions of the normative documents listed below.
GB/T 131 Technical drawings — Method of indicating surface texture (GB/T 131-2006, ISO 1302:1992, IDT)
GB/T 2951.1-1997 Common test methods for insulating and sheathing materials of electric cables — Part 1: Methods for general application — Section 1: Measurement of thickness and overall dimensions — Tests for determining the mechanical properties (idt IEC 60811-1-1:1993)
GB/T 2951.2-1997 Common test methods for insulating and sheathing materials of electric cables — Part 1: Methods for general application — Section 2: Thermal ageing methods (idt IEC 60811-1-2:1985)
GB/T 5013.1-2008 Rubber insulated cables — Rated voltages up to and including 450/750 V — Part 1: General requirements (IEC 60245-1:2003, IDT)
GB/T 5013.3 Rubber insulated cables — Rated voltages up to and including 450/750 V — Part 3: Heat resistant silicone insulated cables (GB/T 5013.3-2008, IEC 60245-3:1994, IDT)
GB/T 5013.4-2008 Rubber insulated cables — Rated voltages up to and including 450/750 V — Part 4: Cords and flexible cables (IEC 60245-4:2004, IDT)
GB/T 5013.8-2006 Rubber insulated cables — Rated voltages up to and including 450/750 V — Part 8: Cords for applications requiring high flexibility (IEC 60245-8:1998, IDT)
GB/T 18380.1 Tests on electric cables under fire conditions — Part 1: Test on a single vertical insulated wire or cable (GB/T 18380.1-2001, IEC 60332-1:1993, IDT)
1.3 Classification of tests according to the frequency with which they are carried out
The tests specified are type tests (symbol T) and/or sample tests (symbol S) as defined in 2.2 of GB/T 5013.1-2008.
The symbols T and S are used in the relevant tables of the particular specifications (GB/T 5013.3, GB/T 5013.4, etc.).
1.4 Sampling
If a marking is in relief in insulation or sheath the samples used for the tests shall be taken so as to include such marking.
For multicore cables, except for the test specified in 1.9, not more than three cores (of different colours, if applicable) shall be tested unless otherwise specified.
1.5 Pre-conditioning
All the tests shall be carried out not less than 16 h after the vulcanization of the insulating or sheathing compounds.
1.6 Test temperature

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 11017.1-2024 in English
Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV(Um=72.5 kV)and 110 kV(Um=126 kV)—Part 1: Test methods and requirements
2024-09-29 -

GB/T 4011-2013 in English
1.2/4.4 mm composite coaxial cable for telecommunication use
2013-07-19 -

GB/T 19216.1-2021 in English
Circuit integrity test for electric cables or optical fiber cables under fire conditions—Part 1: Test method for fire with shock at a temperature of at least 830 ℃ for cables of rated voltage up to and including 0.6/1 kV and with an overall diameter exceeding 20 mm
2021-05-21 -

GB/T 2952.1-2008 in English
Protective coverings for electric cables - Part 1: General
1982-03-22 -

GB/T 14049-2008 in English
Aerial insulated cables for rated voltage of 10kV
2008-06-30 -

GB/T 33343-2016 in English
Test methods of insulated electric wires for aerospace
2016-12-13 -

GB/T 41629.1-2022 in English
Long AC submarine cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500 kV(Um=550 kV)—Part 1: Test methods and requirements
2022-07-11 -

GB/T 45941-2025 in English
Test methods for electric cables with rated voltages up to and including 450/750 V
2025-08-01 -

GB/T 18014-2008 in English
PVC insulated wire for ignition of electric detonators
2008-06-18