Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
electromagnetic starter low voltage explosion protection vacuum starter dual-speed starter triple explosion-proof protection mechanism vertical specimens scopethis standard shanghai daily chemical industry research institute virtual machine management introduction introduction gb/t
GB/T 5590-2024 in English

GB/T 5590-2024 in English

VALID

Low voltage explosion protection electromagnetic starter for mining

  • Issued on:2024-08-23
  • Implemented on:2025-03-01
  • File Format:PDF
  • Delivery:Via email within 5 business days
Price(USD): $510.00
$495.00
Standard No: GB/T 5590-2024
Document status: VALID
Title in English: Low voltage explosion protection electromagnetic starter for mining
Title in Chinese: 矿用防爆低压电磁起动器
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 5 business days
Issued on: 2024-08-23
Implemented on: 2025-03-01
Superseding: GB/T 5590-2008 Low voltage explosion protection electromagnetic starter for mining
ICS Classification: 29.260.20-Electrical apparatus for explosive atmospheres
Chinese Classification: K35-Explosion-proof electric apparatus
Professional Classification: GB-National Standard
Related Keywords: electromagnetic starter
low voltage explosion protection
vacuum starter
dual-speed starter
triple explosion-proof protection mechanism
Related Topics: GBT5590
GB/T 5590-2008
Explosion-proof air compressor voltage
gb5590
gb/t 5590-2008

《GB/T 5590-2024矿用防爆低压电磁起动器》由TC9(全国防爆电气设备标准化技术委员会)归口,主管部门为中国电器工业协会。


Introduction

Background of Standard Revision and Technological Evolution

GB/T5590-2024, as an important standard in the field of explosion-proof electrical equipment for mining, replaced the 2008 version and achieved three major technological breakthroughs:

Technical Dimensions2008 Version2024 VersionUpgrade Points
Explosion-proof TypeSingle Flameproof TypeNewly Added Flameproof and Intrinsically Safe TypeAdapt to Complex Working Conditions Underground
Protection FunctionBasic ProtectionAdd Communication FunctionSupport Intelligent Mine Construction
Mechanical lifeUnclassified10-10 million times classificationPrecisely match different application scenarios

Analysis of core technical requirements

1. Explosion-proof safety system

The standard has established a triple explosion-proof protection mechanism:

  • Flameproof enclosure: Static pressure test pressure ≥1.5 times reference pressure
  • Intrinsically safe circuit: Spark ignition test must pass GB/T3836.4
  • Interlocking device: Mechanical/electrical interlocking gap ≤0.5mm

2. Key performance parameters

Typical case: 1140V vacuum starter must meet the following requirements:

Switching capacity10Ie (COSΦ=0.35)
Electrical lifeAC-3 category ≥ mechanical life 1/20
Electrical leakage lockoutAction value 40kΩ(+20%)

Implementation suggestions

Design stage

  1. Insulating materials with CTI≥600 are preferred
  2. The switching time of the dual-speed starter must be ≤150ms
  3. The starter for wind turbines must have an integrated wind power lockout function

Inspection points

Inspection typeRequired inspection itemsSampling plan
Type inspectionAll 24 major items≥2 units for each item
Factory inspectionItems marked in Table 24100% full inspection

Standard connection

GB/T3836 series explosion-proof standards must be implemented simultaneously, with special attention to:

  • Anti-rust treatment process for explosion-proof surface
  • COT temperature range for non-metallic materials
  • Calibration of intrinsic safety parameters

Sample only — not a preview of GB/T 5590-2024
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.