Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
civil aviation aftn/sita communication system introduction interpretation standard configuration dimensions class monthly master-slave system switchover transmission system configuration specification data interface compatibility data specification bead screens man-machine
MH/T 4050-2018 in English

MH/T 4050-2018 in English

VALID

The configuration specification of civil aviation AFTN/SITA communication system

  • Issued on:2018-12-14
  • Implemented on:2019-04-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $180.00
$175.00
Standard No: MH/T 4050-2018
Document status: VALID
Title in English: The configuration specification of civil aviation AFTN/SITA communication system
Title in Chinese: 民用航空自动转报系统配置规范
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2018-12-14
Implemented on: 2019-04-01
Professional Classification: MH-Civil Aviation
Related Keywords: civil aviation aftn/sita communication system introduction interpretation
standard configuration dimensions class
monthly master-slave system switchover
transmission system
configuration specification
Related Topics: mh/t
Automatic matching
System Configuration Scheme
degree system configuration
Automatic acid preparation
General purpose for aviation automatic test system
mh/t 4049-2018
Aviation automation
Automatic sample matching
Call Home
QB/T 4050


Introduction

Interpretation of the core content of the standard

Configuration dimensions Class I nodes Class II nodes Class III nodes
Processing capacity (shares/hour) ≥50,000 ≥20,000 ≥10,000
Number of synchronous interfaces ≥32 ≥16 Optional
Storage period 6 months 6 months 30 days

Key Technical Requirements

The system must meet the requirements of GPS clock synchronization and dual power redundancy, including:

  • Switchover time: The switchover between the primary and backup systems must be controlled within 5 minutes
  • Communication protocol: The synchronous interface supports X.25/X.75, and the asynchronous interface must be compatible with the RS232 standard
  • Scalability: ATN/AMHS network access capability must be reserved

Implementation Suggestions

Typical deployment plan

Take the first-class node of Capital Airport as an example: configure 2 sets of IBM Power Systems server cluster, using Cisco Nexus switches to build a dual-fiber ring network, and achieving triple routing assurance through MPLS VPN+satellite links.

Operation and maintenance key points

  1. Monthly master-slave system switchover drills
  2. Routing table capacity utilization rate controlled below 80%
  3. Establish interface protocol conversion test environment

Standard evolution analysis

Compared with the 2008 version of the standard, the 2018 version mainly strengthens the following:

  • Added IP user access ratio requirements (Class I nodes ≥ 32)
  • Specified that the transmission system must support FR frame relay and MPLS technologies
  • Detailed three types of node configuration flexibility solutions

Sample only — not a preview of MH/T 4050-2018