Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
centrifuge speed ≥5000r/min solvent extraction use olive oil olive oil-modified method olive oil simulant incomplete extraction composite conduit systems security module -field
SN/T 3182-2012 in English

SN/T 3182-2012 in English

VALID

Food contact materials-Polymers-Test methods for overall migration into olive oil-Modified method for use in case where incomplete extraction of olive oil occurs

  • Issued on:2012-05-07
  • Implemented on:2012-11-16
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $140.00
$136.00
Standard No: SN/T 3182-2012
Document status: VALID
Title in English: Food contact materials-Polymers-Test methods for overall migration into olive oil-Modified method for use in case where incomplete extraction of olive oil occurs
Title in Chinese: 食品接触材料 高分子材料 橄榄油模拟物中总迁移量的试验方法 橄榄油不完全抽提时的改进方法
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2012-05-07
Implemented on: 2012-11-16
Professional Classification: SN-Import&Export Inspection
Related Keywords: centrifuge speed ≥5000r/min solvent extraction use
olive oil
olive oil-modified method
olive oil simulant
incomplete extraction
Related Topics: total migration
Olive Oil Migration
Olive Oil Total Migration
Total Migration:
sn/t+3367-2012
total migration
sn/t3367-2012
migration olive oil
Olive Oil Total Migration
total migration olive oil
olive oil migration
Olive Oil Total Migration
What method is used for polymer materials
food oil material


Introduction

Standard Background and Scope of Application

This standard is equivalent to the international standard EN 1186-10:2002, and proposes an improvement plan for the incomplete extraction problem that occurs when testing the total migration of polymer materials in olive oil simulant. It is applicable to full immersion test scenarios within the temperature range of 5℃-175℃.


Key technical principles

Core steps Technical points Innovation and improvement
Mass difference subtraction Calculate the migration amount by the mass difference before and after the sample is immersed Increase the mandatory requirement of centrifuge speed ≥5000r/min
Solvent extraction Use solvent systems such as dichloromethane/tetrahydrofuran Optimize solvent selection for different plastic types
Methylation reaction Conversion of fatty acids catalyzed by BF3-methanol complex The reaction time is clearly controlled to be 10±1min

Key instrument requirements

The experiment requires the following equipment: centrifuge (≥5000r/min), reflux device, gas chromatograph and other equipment. Glassware such as centrifuge tubes and flasks must meet the accuracy requirements of GB/T 12804-2008.


Operation process optimization

  1. Pretreatment stage: Prepare the sample according to SN/T 2334-2009, and use an antistatic gun to eliminate interference
  2. Extraction stage: Use gradient solvent treatment (dichloromethane→KOH solution→methanol)
  3. Derivatization stage: Strictly control the amount of BF3-methanol added to 5±0.2mL
  4. Result calculation: Correction calculation according to the formula M=[(m₁-(m₂-m₀))-mₐ]×1000/S

Key points of quality control

  • Parallel test ≥3 times, 1 outlier is allowed to be eliminated
  • When the migration amount is >100mg, the amount of internal standard needs to be increased
  • Temperature control deviation does not exceed ±1℃
  • Result report is accurate to 1mg/dm²

Implementation suggestions

Laboratories should note: For PVC materials, tetrahydrofuran solvent is preferred, and PE materials are recommended to use xylene; when there are interferences in the sample, refer to Appendix A for method suitability verification.